Results 4801 - 4810 of 6513
ZX1 Smart Sensor Laser Sensor with Built-in Amplif...
...l output Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to 100 mA)) Analog o...

https://www.ia.omron.com/products/family/3107/specification.html

D4SL-N, D4SL-NSK10-LK[] Guard Lock Safety-door Swi...
...DN 24VDC (without indicator) 4-contact Model Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank []. G1/2 D4SL-N2[]FA-N 1/2-14NPT D4SL-N3[]FA-N M20 D4SL-N4[]FA-N Terminal blo...

https://www.ia.omron.com/products/family/3125/lineup.html

D4SL-N, D4SL-NSK10-LK[] Guard Lock Safety-door Swi...
...C-15 DC-13 Rated operating current (Ie) 1.5 A *1 1 A *2 0.22 A Rated operating voltage (Ue) 120 V 125 V Note: Use a 4 A fuse that conforms to IEC60127 as a short-circuit protection d...

https://www.ia.omron.com/products/family/3125/specification.html

E3FA, E3RA, E3FB, E3RB Photoelectric Sensors/Speci...
... mA max. Control output NPN/PNP (open collector) Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. *2 Operation mode Light-ON/Dark-ON selectable b...

https://www.ia.omron.com/products/family/3130/specification.html

FQ2 Smart Camera/Lineup | OMRON Industrial Automat...
...or FQ-SDU2 * 2 m FQ-VP2002 5 m FQ-VP2005 10 m FQ-VP2010 RS-232C Cable for FQ-SDU2 2 m XW2Z-200S-V 5 m XW2Z-500S-V * When using FQ-SDU[][], 2 Cables are required for all I/O signals. ...

https://www.ia.omron.com/products/family/3131/lineup.html

E2EF Proximity Sensor with All-stainless Housing/S...
...ut configuration With polarity Control output Switching capacity 3 to 100 mA Residual voltage 3 V max.(Load current: 100 mA max., Cable length: 2 m) Indicators Operation indicator (red LED), ...

https://www.ia.omron.com/products/family/3144/specification.html

R88L-EC, R88D-KN[]-ECT-L G5 Series Linear Motor/Se...
...0 20 25 Motor force constant N/Arms 39.7 39.7 46.5 46.5 46.5 93.0 93.0 Back electromotive force V・s/m 13.2 13.2 15.5 15.5 15.5 31 31 Motor constant N/√W 9.75 13.78 19.49 23.87 27.57 41.47 46...

https://www.ia.omron.com/products/family/3145/specification.html

FQ2-CH Series Optical Character Recognition Sensor...
...or FQ-SDU2 * 2 m FQ-VP2002 5 m FQ-VP2005 10 m FQ-VP2010 RS-232C Cable for FQ-SDU2 2 m XW2Z-200S-V 5 m XW2Z-500S-V * When using FQ-SDU[][], 2 Cables are required for all I/O signals. ...

https://www.ia.omron.com/products/family/3149/lineup.html

E5AC Digital Temperature Controller (96 x 96 mm)/S...
...5°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Current input: 150 Ω max., Voltage ...

https://www.ia.omron.com/products/family/3157/specification.html

ZS Series Smart Sensor 2D Measurement Type/Specifi...
...ent output HIGH/PASS/LOW 3 outputs NPN open collector, 30 VDC, 50 mA max., residual voltage 1.2 V max. HIGH/PASS/LOW: 3 outputs PNP open collector, 50 mA max., residual voltage 1.2 V...

https://www.ia.omron.com/products/family/3175/specification.html

Results 4801 - 4810 of 6513