Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 4791 - 4800 of 6521
FQ-CR Series Code Reader/Specifications | OMRON In...
...FQ-BAT1 Battery type Secondary lithium ion battery Nominal capacity 1,800 mAh Rated voltage 3.7 V Ambient temperature range Operating: 0 to 40°C Storage: - 25 to 65°C (with no icing or conden...

https://www.ia.omron.com/products/family/3070/specification.html

CJ1W-V680C11 / V680C12 CJ Series ID Sensor Unit/Sp...
... 19, 2013 General Specification Model CJ1W-V680C11 CJ1W-V680C12 Current consumption Internal: 5 V 0.26 A 0.32 A Internal: 24 V/26 V 0.13 A * 0.26 A External: 24 V -...

https://www.ia.omron.com/products/family/3086/specification.html

CS1W-V680C11 / V680C12 CS Series ID Sensor Unit/Sp...
... 19, 2013 General Specification Model CS1W-V680C11 CS1W-V680C12 Current consumption Internal: 5 V 0.26 A 0.32 A Internal: 24 V/26 V 0.13 A * - External: 24 V - 0.36...

https://www.ia.omron.com/products/family/3087/specification.html

E5CC, E5CC-B, E5CC-U Digital Temperature Controlle...
...5°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies to the E5C...

https://www.ia.omron.com/products/family/3101/specification.html

E5EC, E5EC-B Digital Temperature Controller (48 x ...
...5°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Current input: 150 Ω max., Voltage ...

https://www.ia.omron.com/products/family/3102/specification.html

ZX0 CMOS Laser Sensor with Built-in Amplifier/Spec...
...l output Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to 100 mA)) Monitor ...

https://www.ia.omron.com/products/family/3104/specification.html

ZX1 Smart Sensor Laser Sensor with Built-in Amplif...
...l output Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to 100 mA)) Analog o...

https://www.ia.omron.com/products/family/3107/specification.html

D4SL-N, D4SL-NSK10-LK[] Guard Lock Safety-door Swi...
...DN 24VDC (without indicator) 4-contact Model Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank []. G1/2 D4SL-N2[]FA-N 1/2-14NPT D4SL-N3[]FA-N M20 D4SL-N4[]FA-N Terminal blo...

https://www.ia.omron.com/products/family/3125/lineup.html

D4SL-N, D4SL-NSK10-LK[] Guard Lock Safety-door Swi...
...C-15 DC-13 Rated operating current (Ie) 1.5 A *1 1 A *2 0.22 A Rated operating voltage (Ue) 120 V 125 V Note: Use a 4 A fuse that conforms to IEC60127 as a short-circuit protection d...

https://www.ia.omron.com/products/family/3125/specification.html

E3FA, E3RA, E3FB, E3RB Photoelectric Sensors/Speci...
... mA max. Control output NPN/PNP (open collector) Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. *2 Operation mode Light-ON/Dark-ON selectable b...

https://www.ia.omron.com/products/family/3130/specification.html

Results 4791 - 4800 of 6521