E6C2-C Slim Incremental 50-mm-dia. Rotary Encoder/...
...stance 100 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destructio...

https://www.ia.omron.com/products/family/488/specification.html

E6F-C Incremental 60-mm-dia. Rotary Encoder/Specif...
...istance 20 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destructio...

https://www.ia.omron.com/products/family/490/specification.html

E6CP-A Low-cost Encoder with Diameter of 50 mm/Spe...
...stance 200 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destructio...

https://www.ia.omron.com/products/family/494/specification.html

E4E2 Compact Ultrasonic Sensor/Specifications | OM...
...ance 100 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,500 VAC (50/60 Hz) for 1 min between current-carrying parts and case Vibration resistance Destructi...

https://www.ia.omron.com/products/family/504/specification.html

K7L-AT50[] / AT50D[][] Liquid Leakage Sensor Ampli...
...n resistance 10 MΩ at 100 VDC between case and current-carrying parts Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between case and current-carrying parts Power consumption 1 W max. Re...

https://www.ia.omron.com/products/family/564/specification.html

S3D2 Sensor Controller/Lineup | OMRON Industrial A...
...st update: October 3, 2016 Power supply voltage Output Timer function Features Model 100 to 240 VAC Relay No Single-function with one input/output (two circuits) S3D2-DK Yes S3D2-EK No Single...

https://www.ia.omron.com/products/family/571/lineup.html

K3MA-J Process Meter/Lineup | OMRON Industrial Aut...
... 6, 2014 Input type Supply voltage Comparative Output Model Model DC voltage/current 100 to 240 VAC None * K3MA-J 100-240VAC 2 relay contact outputs (SPST-NO) K3MA-J-A2 100-240VAC 24 ...

https://www.ia.omron.com/products/family/588/lineup.html

K3MA-J Process Meter/Specifications | OMRON Indust...
...00-240VAC, K3MA-J-A2 100-240VAC K3MA-J 24VAC/VDC, K3MA-J-A2 24VAC/VDC Supply voltage 100 to 240 VAC 24 VAC/VDC Operating voltage range 85% to 110% of the rated supply voltage Power c...

https://www.ia.omron.com/products/family/588/specification.html

K3MA-L Temperature Meter/Lineup | OMRON Industrial...
...put type Supply voltage Output Model Platinum-resistance thermometer or thermocouple 100 to 240 VAC None K3MA-L 100-240VAC 1 relay contact output (SPDT) K3MA-L-C 100-240VAC 24 VAC/VD...

https://www.ia.omron.com/products/family/589/lineup.html

K3MA-F Frequency/Rate Meter/Lineup | OMRON Industr...
...February 13, 2014 List of Models Input type Supply voltage Output Model Rotary pulse 100 to 240 VAC None K3MA-F 100-240VAC 2 relay contact outputs (SPST-NO) K3MA-F-A2 100-240VAC 24 ...

https://www.ia.omron.com/products/family/590/lineup.html