PDFIO-Link Master Unit GD Series Empowering engineers
...log input 4 to 20 mA K3CV-1ADIA-IL3 Analog input 0 to 20 mA K3CV-1ADIB-IL3 Analog input 0 to 10 V K3CV-1ADVA-IL3 Analog input: -10 to 10 V K3CV-1ADVB-IL3 Thermocouple K Thermocouple ...

https://www.ia.omron.com/data_pdf/cat/gd_series_e633-e1_1_1_csm1133685.pdf

PDF1 Safety I/O Terminal GI-S Series GI-SMD/SID
...t 0.5 A max. *2 Maximum total safety output current 2.0 A Safety output ON residual voltage 1.2 V max. (between V1 and each output terminal) Safety output OFF residual voltage 2.0 V ...

https://www.ia.omron.com/data_pdf/cat/gi-smd_sid_f126-e1_4_1_csm1124267.pdf

PDFCSM_GX_DS_E_9_16 1 EtherCATRemote I/O Terminals G...
...Section Specifications 16-point Input Terminals Note: For the I/O power supply current value to V and G terminals, refer to GX Series Operation Manual (Cat. No. W488). Output Section Specific...

https://www.ia.omron.com/data_pdf/cat/gx_ds_e_9_16_csm1003469.pdf

PDFModel Selection Guide for Timers
... be switched. Transistor output: NPN open-collector 30 VDC max. 100 mA max. residual voltage: 2 V max. 1.There are NPN (sinking) and PNP (sourcing) transistor outputs. 2.Confirm that the ...

https://www.ia.omron.com/data_pdf/cat/h3_h5_timer_selection_guide_l130-e1_2_1_csm1129246.pdf

PDF1 Solid-state Timer H3CR Please read and understan...
... 30 VDC, Ie: 0.5 A Transistor Output: DC-13: Ue: 30 VDC, Ie: 0.1 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...

https://www.ia.omron.com/data_pdf/cat/h3cr_l084-e1_3_6_csm1013792.pdf

PDF1 Solid-state Timers H3DK DIN Track-mounted, 22.5-...
..., Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 0.1 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...

https://www.ia.omron.com/data_pdf/cat/h3dk_l118-e1_7_7_csm2645.pdf

PDFCSM_H3DS_DS_E_5_4 1 Solid-state Timer H3DS
...tart B1 Start Voltage Input Signal Levels No-contact input 1. Transistor ON Residual voltage: 1 V max. (Voltage between terminals B1 and A2 must be more than the rated "H-level" voltage (20.4...

https://www.ia.omron.com/data_pdf/cat/h3ds_ds_e_5_4_csm88.pdf

PDF1 Solid-state Timers H3DT DIN 17.5-mm-wide Slim Ti...
...er supply) Voltage Input Signal Levels Tran- sistor input 1. Transistor ON •Residual voltage: 1 V max. Voltage between terminals B1 and A2 must be equal to or higher than the rated high level...

https://www.ia.omron.com/data_pdf/cat/h3dt_m090-e1_4_8_csm1050135.pdf

PDFSolid-state Timers H3DT More Advanced Timers for N...
... New Area, Shanghai, 200120, China Tel: (86) 21-6023-0333 Fax: (86) 21-5037-2388 OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31) 2356-81-300 Fax: (31) 2356-81-38...

https://www.ia.omron.com/data_pdf/cat/h3dt_m091-e1_2_1_csm1050133.pdf

PDFCSM_H3FA_DS_E_8_3 1 Solid-state Timer H3FA
...ion, time-limit resetting/external resetting 4. Supply voltage For contact output models 5DC: 5 V DC 6DC: 6 V DC 12DC: 12 V DC 24DC: 24 V DC For solid-state output ...

https://www.ia.omron.com/data_pdf/cat/h3fa_ds_e_8_3_csm89.pdf

Results 6141 - 6150 of 6485