Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 6141 - 6150 of 6520
PDFCSM_G3FM_DS_E_6_3 1 Solid State Relays G3FM
...VDC 1.2 kΩ±20% 19.2 VDC Operate time 5 ms max. Release time 10 ms max. Output ON voltage drop 3 V (RMS) max. Leakage current 0.1 mA max. (at 200 VAC) Insulation resistance 100 MΩmin. (at 500 ...

https://www.ia.omron.com/data_pdf/cat/g3fm_ds_e_6_3_csm152.pdf

PDFCSM_G3H_G3HD_DS_E_8_3 1 Solid State Relays G3@-VD ...
...time 1/2 cycle of load power source + 1 ms max. 2 ms max. 10 ms max. Output ON voltage drop 1.6 V (RMS) max. 3 V max. (output ON-resis- tance: 1.25Ωmax.) Leakage current 5 mA max. (a...

https://www.ia.omron.com/data_pdf/cat/g3h_g3hd_ds_e_8_3_csm154.pdf

PDF1 Solid State Relays G3NA The reliable choice for ...
...24 to 240 VAC 19 to 264 VAC 0.1 to 5 A (at 40°C) 0.1 to 3 A (at 40°C) 60 A (60 Hz, 1 cycle) 600 V (VDRM) G3NA-210B-UTU 0.1 to 10 A (at 40°C) 0.1 to 4 A (at 40°C) 150 A (60 Hz, 1 cycle) G3NA-2...

https://www.ia.omron.com/data_pdf/cat/g3na_j166-e1_2_11_csm1057968.pdf

PDF1 CSM_G3NE_DS_E_5_3 Solid State Relays G3NE
...NE Compact, Low-cost, SSR Switching 5 to 20 A •Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. •Dedicated, compact aluminum PCB...

https://www.ia.omron.com/data_pdf/cat/g3ne_ds_e_5_3_csm166.pdf

PDFCSM_G3PE-Single-phase_DS_E_2_12
...x. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 10 mA max. (at 200 VAC) Insulation resistance 100 MΩmin. (at 500 V...

https://www.ia.omron.com/data_pdf/cat/g3pe-single-phase_ds_e_2_12_csm1854.pdf

PDFCSM_G3PE-Three-phase_DS_E_4_10
... + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current * 10 mA max. (at 200 VAC) 20 mA max. (at...

https://www.ia.omron.com/data_pdf/cat/g3pe-three-phase_ds_e_4_10_csm1855.pdf

PDF1 CSM_G3PE_CN_E_4_4 Safety Precautions for All G3P...
...malfunction withstand limit is shown below. •Malfunction withstand limit (reference value): 500 V Note: This value was measured under the following conditions. Noise duration: 100 ns and 1μs ...

https://www.ia.omron.com/data_pdf/cat/g3pe_cn_e_4_4_csm1856.pdf

PDFCSM_G3PF_DS_E_7_12 1 Solid State Relays with Built...
...Release time 1/2 of load power source cycle + 1 ms max. Main circuit Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current 10 mA max. (at 200 VAC) 20 mA max. (at 4...

https://www.ia.omron.com/data_pdf/cat/g3pf_ds_e_7_12_csm748.pdf

PDF1 High-power Solid State Relays
... + 1 ms max. for AC input 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 30 mA max. (at 240 VAC) 60 mA max. (at 480 VAC) 30 mA max. (at 240...

https://www.ia.omron.com/data_pdf/cat/g3ph_j177-e1_2_2_csm1000554.pdf

PDF1 Solid State Relays for Heaters
... + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current 10 mA max. (at 240 VAC) 20 mA max. (at 4...

https://www.ia.omron.com/data_pdf/cat/g3pj_j210-e1_4_3_csm1050153.pdf

Results 6141 - 6150 of 6520