Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 6151 - 6160 of 6516
PDF1 Single-phase Power Controller
...onditions ON: 1 kΩmax., OFF: 100 kΩmin. Non-contact input condi- tions ON residual voltage: 1.0 V max., OFF leakage current: 0.1 mA max. Current flow Approx. 1.1 mA (per input) Output voltage...

https://www.ia.omron.com/data_pdf/cat/g3pw_j176-e1_16_1_csm2000.pdf

PDFCSM_G3R-I/O_DS_E_5_11 1 I/O Solid State Relays G3R...
...ms max. 15 ms max. Release time Response frequency 10 Hz 1 kHz 10 Hz Output ON voltage drop 1.6 V max. Leakage current 5µA max. Insulation resistance 100 MΩmin. between I/O Dielectric strengt...

https://www.ia.omron.com/data_pdf/cat/g3r-i_o_ds_e_5_11_csm2416.pdf

PDFCSM_G3TA_DS_E_5_1 1 Solid State Relays G3TA
...put Output models: DC output 5. Rated Load Power Supply Voltage 2: 200 VAC/200 VDC X: 50 to 100 V Z: 26 V max. 6. Rated Load Current 01: 1 A 02: 2 A R02: 25 mA 7. Terminal Type S: Pl...

https://www.ia.omron.com/data_pdf/cat/g3ta_ds_e_5_1_csm174.pdf

PDFCSM_G3ZA_DS_E_6_4 1 Multi-channel Power Controller...
...tor, one output Max. applicable voltage: 30 VDC, Max. load current: 50 mA Residual voltage: 1.5 V max., Leakage current: 0.4 mA max. Indications LED indicators Control method Optimum cycle co...

https://www.ia.omron.com/data_pdf/cat/g3za_ds_e_6_4_csm192.pdf

PDFCSM_G4Q_DS_E_3_2 1 Ratchet Relay G4Q
...ent (mA) Resistance (Ω) Must operate Must release Max. voltage Power consumption Rated voltage (V) 50 Hz 60 Hz % of rated voltage Initial Rated AC 12 614 531 2.24 80 % max. 10 % min. 110 % ma...

https://www.ia.omron.com/data_pdf/cat/g4q_ds_e_3_2_csm44.pdf

PDF〉〉EtherCAT 〉〉International Safety Standards
... motor movement Command speed to motor Stabilization time 0.3 ms* 38nm 4.8nm *Applicable to 100 V/200 V models with 750 W or less. High Speed and High Precision 1.2 times faster than...

https://www.ia.omron.com/data_pdf/cat/g5_series_i815-e1_29_32_csm2106.pdf

PDFCSM_G6B-4__ND_G3S4_DS_E_5_1 1 Terminal Relay/Termi...
...wance. 4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A). 5. The values in parentheses are for the G6B-4FB1ND and G6B-4FPND. 6....

https://www.ia.omron.com/data_pdf/cat/g6b-4__nd_g3s4_ds_e_5_1_csm1057979.pdf

PDF1 Terminal Relay G6D-F4PU/G3DZ-F4PU (Push-In Plus ...
...uencies/min. Operation coil rating Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consump tion (mW) DC 12 18...

https://www.ia.omron.com/data_pdf/cat/g6d-f4pu_g3dz-f4pu_g6d-f4b_g3dz-f4b_j228-e1_1_10_csm1070913.pdf

PDF1 I/O Terminal Socket G70A 16-point I/O Terminal S...
...n between connectors Insulation resistance Between connector and I/O terminals: 1,000 MΩ(at 500 V) Other: 100 MΩ(at 500 V) Vibration resistance Malfunction: 10 to 61.2 to 10 Hz, 0.1-...

https://www.ia.omron.com/data_pdf/cat/g70a_j087-e1_1_9_csm1057151.pdf

PDFCSM_G70D-SOC08_DS_E_5_1 1 Relay Terminal G70D-SOC0...
...nts Internal I/O common Rated voltage Model Relay outputs 8 points (SPST-NO×8) NPN (+common) 24 V DC G70D-SOC08 Applicable Output Relay Terminals Model G70D-SOC08 G70R-SOC08 G6B-4-SB Applicab...

https://www.ia.omron.com/data_pdf/cat/g70d-soc08_ds_e_5_1_csm1046356.pdf

Results 6151 - 6160 of 6516