NX502-[][][][] NX-series NX502 CPU Units/Specifica...
...minal and NX Unit power supply I/O Power Supply to NX Units Not provided *6 Power supply to the X Bus Unit power supply *7 X Bus Unit power supply capacity 50 W max. Isolation method...

https://www.ia.omron.com/products/family/3900/specification.html

NX-HTC NX-series Advanced Temperature Control Unit...
... 5 to 8.4 Hz with amplitude of 3.5 mm, 8.4 to 150 Hz, acceleration of 9.8 m/s 2 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Shock resistance Conforms to ...

https://www.ia.omron.com/products/family/3902/specification.html

E3Z-[]-UL Compact Photoelectric Sensor with Built-...
... min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s 2 3 times each in X, Y, a...

https://www.ia.omron.com/products/family/3919/specification.html

R88D-1SN[]-ECT-51 AC Servo System 1S-series with S...
...phere No corrosive gases Vibration resistance *1 Acceleration of 49 m/s 2 *2 24.5 m/s 2 max. in X, Y, and Z directions when the motor is stopped Impact resistance Acceleration of 98 m/s 2 max...

https://www.ia.omron.com/products/family/3923/specification.html

DeviceNet Peripheral Devices DeviceNet Peripheral ...
...lat Cable DCA4-4F10 Four-core flat cable (UL 2555) Length: 100 m Conductor diameters: 0.75 mm 2 x 2, 0.5 mm 2 x 2 Simple Manual Crimp Tool DWT-A01 This is the crimping tool for the f...

https://www.ia.omron.com/products/family/783/lineup.html

S8VS Switch Mode Power Supply (15/30/60/90/120/180...
...rminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s 2 , 3 times each in ±X, ±Y, and ±Z dir...

https://www.ia.omron.com/products/family/807/specification.html

Further Information of Solid-state Relays | OMRON ...
...0 A. The value of the protective resistance R is obtained from the following formula: R > 220 V x √2/200 A = 1.4 Ω Considering the circuit current and ON time, insert the protective resistanc...

https://www.ia.omron.com/support/guide/18/further_information.html

PDFSensors Switches Safety Components Relays Control ...
...nput) No Phototriac G3TA-OA G3PE-2@@BL G3PH, G3F, G3H, G3R-OA G3S, G3CN Yes Phototriac G3PA-VD(-X) G3PA-2@@B G3PE-2@@B (single phase) G3NA (DC input) G3NA-2@@B-UTU G3NE G3F G3H Yes Phototriac...

https://www.ia.omron.com/data_pdf/guide/18/ssr_tg_e_9_12.pdf

PDFSensors Switches Safety Components Relays Control ...
...o output devices. Power Supply Section Input Section Timing Section Output Section No. Function X Switches between time adjustment mode, the operation setting modes, and run mode. Y Sets hour...

https://www.ia.omron.com/data_pdf/guide/19/timer_timeswitch_tg_e_7_5.pdf

PDFSensors Switches Safety Components Relays Control ...
...t aligned with the movement direction of the dog or the Limit Switch is actuated by two dogs in X and Y directions. Bevel plunger Small Medium Large★★★★★★ Unlike roller plungers, the bevel pl...

https://www.ia.omron.com/data_pdf/guide/30/limitswitch_apparatus_tg_e_3_2.pdf