E2EC-C1R5D15 5M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1000/

E2EC-C1R5D2 5M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1002/

E2EC-C1R5D25 2M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1003/

E2EC-C1R5D25 5M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1004/

E2EC-C2R5C1 5M | OMRON Industrial Automation
...and the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 500 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1006/

E2EC-C3D1 5M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1008/

E2EC-C3D15 2M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1009/

E3NC-LH01 2M | OMRON Industrial Automation
...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm or 100 m/s 2 double am...

https://www.ia.omron.com/product/item/101/

E2EC-C3D15 5M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1010/

E2EC-C3D2 5M | OMRON Industrial Automation
...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/1013/