Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 781 - 790 of 6516
E6F-C Incremental 60-mm-dia. Rotary Encoder/Specif...
... Complementary outputs *2 NPN open-collector output Output capacity Output voltage: VH = Vcc -3 V min. (Io = 30 mA), VL = 2 V max. (Io = -30 mA) Output current: ±30 mA Applied voltag...

https://www.ia.omron.com/products/family/490/specification.html

E6H-C Hollow-shaft Encoder with Diameter of 40 mm/...
... *4 Output capacity Applied voltage: 35 VDC max. Sink current: 35 mA max. Residual voltage: 0.7 V max. (at sink current of 35 mA) Output resistance: 1 kΩ Sink current: 30 mA max. Residual vol...

https://www.ia.omron.com/products/family/491/specification.html

E6CP-A Low-cost Encoder with Diameter of 50 mm/Spe...
...put Output capacity Applied voltage: 28 VDC max. Sink current: 16 mA max. Residual voltage: 0.4 V max. (at sink current of 16 mA) Maximum response frequency *2 5 kHz Logic Negative logic (hig...

https://www.ia.omron.com/products/family/494/specification.html

E63-WF Direct Discrimination Unit/Specifications |...
...es A, B, and Z (phase difference signals) Phase difference 90° ±45° max. ON 6 mA max. at 0 to 2 V OFF 1.5 mA max. at 8 to 24 V Input short current 9 mA Max. applied voltage 30 ...

https://www.ia.omron.com/products/family/498/specification.html

E4E2 Compact Ultrasonic Sensor/Specifications | OM...
...sponse frequency 20 Hz max. Power supply voltage (operating voltage range) 24 VDC (21.6 to 26.4 V) with a max. ripple (p-p) 10% Current consumption E4E2-TS50TC1 Emitter: 25 mA max. at 24 VDC ...

https://www.ia.omron.com/products/family/504/specification.html

K7L-AT50[] / AT50D[][] Liquid Leakage Sensor Ampli...
... insulated 3-conductor VCT cable with a thickness of 0.75 mm 2 and a dielectric strength of 600 V is used together with a Liquid Sensing Band specified by OMRON. (A 0.2-mm 2 cable can also be...

https://www.ia.omron.com/products/family/564/specification.html

S3D2 Sensor Controller/Lineup | OMRON Industrial A...
...bers have the suffix B (e.g.,    S3D2-AKB) Differences from NPN Models Input signals ON 8 to 12 V (5 mA min.) OFF 0 to 4 V (2 mA max.) Maximum applied voltage 12 V Note: S3D...

https://www.ia.omron.com/products/family/571/lineup.html

K3MA-J Process Meter/Specifications | OMRON Indust...
... and case. Insulation provided between inputs, outputs, and power supply. Noise immunity ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise wi...

https://www.ia.omron.com/products/family/588/specification.html

K3MA-F Frequency/Rate Meter/Specifications | OMRON...
... and case. Insulation provided between inputs, outputs, and power supply. Noise immunity ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise wi...

https://www.ia.omron.com/products/family/590/specification.html

XS3 Round Water-resistant Connectors (M8/S8)/Speci...
...Fixture Brass/nickel plating or SUS316L — Brass/ nickel plating — Contact block PBT resin (UL94 V-0) O-ring Rubber Cover Soft PBT resin *2 — TPEE — *1. Except 5 poles *2. Except XS3R-M426-405...

https://www.ia.omron.com/products/family/781/specification.html

Results 781 - 790 of 6516