Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 761 - 770 of 6477
E39-VA Hand-held Checker/Specifications | OMRON In...
...pecifications Dimensions Catalog last update: December 13, 2012 Ratings Power supply voltage 18 V (use two 9-V dry-cell batteries) Input configuration Operates when the output transi...

https://www.ia.omron.com/products/family/432/specification.html

EE-SPX74 / SPX84 Slot-type Photomicrosensor with C...
... current: 50 mA max. OFF current: 0.5 mA max. 50 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency * 2...

https://www.ia.omron.com/products/family/437/specification.html

EE-SPX-W Slot-type Photomicrosensor with Cable/Spe...
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *2 ...

https://www.ia.omron.com/products/family/438/specification.html

EE-SPX301 / 401, EE-SPY30 / 40 Slot-type Reflectiv...
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *3 ...

https://www.ia.omron.com/products/family/440/specification.html

EE-SPY31 / 41 Light Convergent Reflective Photomic...
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *3 ...

https://www.ia.omron.com/products/family/443/specification.html

EE-SY671 / 672 Reflective Photomicrosensor with Se...
...urrent: 100 mA max. OFF current: 0.5 mA max. 100 mA load current with a residual voltage of 0.8 V max. 40 mA load current with a residual voltage of 0.4 V max. Response frequency *2 ...

https://www.ia.omron.com/products/family/444/specification.html

E2EZ Chip-immune Inductive Proximity Sensor/Specif...
...tput 100 mA max. at 12 VDC (30 VDC max.) 200 mA max. at 24 VDC (30 VDC max.) Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) 2 V max. (Load current: 200 mA, Cable...

https://www.ia.omron.com/products/family/454/specification.html

E2EY Aluminum-detecting Proximity Sensor/Specifica...
...ntrol output Load current NPN open-collector output, 100 mA max. (at 30 VDC) Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Operation...

https://www.ia.omron.com/products/family/457/specification.html

E2K-X Cylindrical Proximity Sensor/Specifications ...
...urrent E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA Residual voltage E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on Data S...

https://www.ia.omron.com/products/family/471/specification.html

E2K-F Flat Proximity Sensor/Specifications | OMRON...
...DC Control output Load current NPN open collector, 100 mA max. (at 30 VDC) Residual voltage 1.5 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Number of...

https://www.ia.omron.com/products/family/472/specification.html

Results 761 - 770 of 6477