| Site Search | Product Search | IA Global Search |
...d and may not function properly. (4) Mounting Mount G9SX-NS□to DIN rails with attachments (TYPE PFP-M, not incorporated to this product), not to drop out of rails by vibration etc. especially...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-nsa222-t03-__ns202-__inst-0631752-3j.pdf
...aged and may not function properly. (3) Mounting Mount G9SX to DIN rails with attachments (TYPE PFP-M, not incorporated to this product), not to drop out of rails by vibration etc. especially...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-sm032-__inst-1624714-0g.pdf
...aged and may not function properly. (3) Mounting Mount G9SX to DIN rails with attachments (TYPE PFP-M, not incorporated to this product), not to drop out of rails by vibration etc. especially...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-sm032-__inst-2166131-1c.pdf
...aged and may not function properly. (3) Mounting Mount G9SX to DIN rails with attachments (TYPE PFP-M, not incorporated to this product), not to drop out of rails by vibration etc. especially...
https://www.fa.omron.com.cn/data_pdf/mnu/g9sx-sm032-__inst-3080529-6f.pdf
...wall. Screw the DIN Track in three or more places in a control cabinet. Recommended DIN Track PFP-M End Plate (2 Pieces) Installation Direction There is no particular restriction on the mo...
https://www.fa.omron.com.cn/data_pdf/mnu/h231-e1-07_k6pm-th.pdf
...应无松动请完全锁定DIN导轨安装挂钩。 连接电缆的连接器是否完全插入并锁定? 应无松动请完全插入并锁定。 端板(PFP-M)的螺钉是否松动?应无松动请使用十字螺丝刀拧紧。 多个NX单元是否沿着连接导向件连接...
...ness Correct any improperly installed connectors. Are there any loose screws on the End Plates (PFP-M)? No looseness Tighten loose screws with a Phillips-head screw- driver. Are the NX Units ...
https://www.fa.omron.com.cn/data_pdf/mnu/h238-e1-01_nx-htc____.pdf
...体时,可安装至DIN导轨或使用螺钉安装至壁面。 DIN导轨在控制柜内使用3处以上的螺钉进行固定。 ●推荐DIN导轨 ●端板PFP-M(2个) ●安装方向 K6PM-TH的安装方向没有特殊限制,请尽量在水平或垂直方向上牢固安装...
https://www.fa.omron.com.cn/data_pdf/mnu/k6pm-th_sgtd-cn5-749g.pdf
...wall. Screw the DIN Track in three or more places in a control cabinet. Recommended DIN Track PFP-M End plate (2 pieces) Installation Direction There is no particular restriction on the mo...
https://www.fa.omron.com.cn/data_pdf/mnu/n219-e1-16_k6cm.pdf
...0×35×7.3 mm (L×W×H) OMRON PFP-50N 500×35×7.3 mm (L×W×H) OMRON Model Specifications Manufacturer PFP-M For PFP-100N/PFP-50N OMRON (1) (2) (3) 30 mm above End plate End plate Downward Vertical ...
https://www.fa.omron.com.cn/data_pdf/mnu/n224-e1-07_k7ge-mg.pdf
...m high OMRON PFP-50N 500 mm long×35 mm wide×7.3 mm high OMRON Model Specifications Manufacturer PFP-M For PFP-100N/PFP-50N OMRON (1) (2) (3) Upright installation direction End Plate End Plate...
https://www.fa.omron.com.cn/data_pdf/mnu/n227-e1-07_k7tm.pdf
...m high OMRON PFP-50N 500 mm long×35 mm wide×7.3 mm high OMRON Model Specifications Manufacturer PFP-M For PFP-100N/PFP-50N OMRON Removing from the DIN Track (1) (2) (3) 2) 1) End Plate End Pl...
https://www.fa.omron.com.cn/data_pdf/mnu/n233-e1-04_k7dd.pdf
...from jumping off the DIN rail due to vibration or impacts. –End plate (recommended part): model PFP-M (from Omron) •Make sure you install so there is space for wiring above and below the body...
https://www.fa.omron.com.cn/data_pdf/mnu/n241-e1-01_km-pmbn-eip.pdf
...御盤に取り付ける際は、DINレール(TH35-7.5/ TH35-15:IEC60715)を使用してください。 振動による脱落防止のためエンドプレート(形PFP-M、別売)を使用して形NE1A-EDR01を DINレールに固定してください。 ...
https://www.fa.omron.com.cn/data_pdf/mnu/ne1a-edr01_inst-1625081-8g.pdf
...。 ・制御盤に取り付ける際は、DINレール(TH35-7.5:IEC60715)を使用してください。 振動による脱落防止のためエンドプレート(形PFP-M、別売)を使用して形NE1A-SCPU01-EIPをDINレールに固定してくださ...
https://www.fa.omron.com.cn/data_pdf/mnu/ne1a-scpu01-eip_inst-2162121-2d.pdf
...。 ・制御盤に取り付ける際は、DINレール(TH35-7.5:IEC60715)を使用してください。 振動による脱落防止のためエンドプレート(形PFP-M、別売)を使用して形NE1A-SCPU01-V1をDINレールに固定してください...
https://www.fa.omron.com.cn/data_pdf/mnu/ne1a-scpu01-v1_inst-0631729-9i.pdf
...。 ・制御盤に取り付ける際は、DINレール(TH35-7.5:IEC60715)を使用してください。 振動による脱落防止のためエンドプレート(形PFP-M、別売)を使用して形NE1A-SCPU02-EIPをDINレールに固定してくださ...
https://www.fa.omron.com.cn/data_pdf/mnu/ne1a-scpu02-eip_inst-2163880-8d.pdf
...。 ・制御盤に取り付ける際は、DINレール(TH35-7.5:IEC60715)を使用してください。 振動による脱落防止のためエンドプレート(形PFP-M、別売)を使用して形NE1A-SCPU02をDINレールに固定してください。 ...
https://www.fa.omron.com.cn/data_pdf/mnu/ne1a-scpu02_inst-0631730-2i.pdf
...等軌ゴコ=二直・一 長:50cm;商、7.3cm PFP-50N ・民、lem滴】7,3cm PFP・1-100N 長、1cm;高:16cm PFP-100N2 頂端板_手一ーーマ〔 ,.■ PFP-M 定鯉筒鳥` .,■ PFP-S 注:DIN早軌,順鞘板和定位染方貨,以十件カー...
https://www.fa.omron.com.cn/data_pdf/mnu/oez-zcp97201a_c200hx_c200hg_c200he.pdf
...P-50N ●支撑导轨(铝制) PFP-100N2 4.5 15 25 25 10 10 1,000 25 25 15 1 1.5 29.2 24 27 35±0.3 16 ●固定件(端板) PFP-M ※1:如果有振动或冲击,可能因铝的磨损而产生金属屑,因此请使用铁制DIN导轨。 ...
https://www.fa.omron.com.cn/data_pdf/mnu/ppmn-c-001d_s8ba-24d24d___lf.pdf