Site Search | Product Search | IA Global Search |
...ber setting switch This rotary switch sets the unit number on the CPU Unit with one hexadecimal digit. Node address setting switches These two rotary switches set the node address for the Eth...
https://www.omron-ap.co.in/data_pdf/cat/cj1w-eip21s_ds_e_1_2_csm1129631.pdf
...2 ABCD x16 1 6789 345 6789 EF012 345 TS UNIT No. Unit Number Switch Sets the unit number in one digit hexadecimal. NODE No. 0 x16 Node Number Switches Set the Unit's FINS node number in two d...
https://www.omron-ap.co.in/data_pdf/cat/cj1w-fln22_ds_e_3_4_csm2177.pdf
... Unit Name Function Unit number switch (UNIT NO.) Sets the unit number of the SPU Unit as a one-digit hexadecimal value. Do not set the same unit number for more than one CPU Bus Unit under t...
https://www.omron-ap.co.in/data_pdf/cat/cj1w-spu01-v2_ds_e_7_8_csm2167.pdf
...cial I/O Unit area.) Indication accuracy Celsius: ±0.3% of PV or ±1°C (whichever is larger) ± 1 digit max. Fahrenheit: ±0.3% of PV or ±2°F (whichever is larger) ± 1 digit max. • L an...
https://www.omron-ap.co.in/data_pdf/cat/cj1w-tc_ds_e_2_2_csm1622.pdf
...efreshed during overseeing processing. Use PRV(881) to read the most recent PVs. Data format: 8 digit hexadecimal • Linear mode: • Ring mode: Control method 8000 0000 to 7FFF FFFF hex 0000 00...
https://www.omron-ap.co.in/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf
...n investigation) • EtherCAT for flexible system configurationAdvanced security function with 32 digit security password Secure host connection • The OPC UA and MQTT communication are supporte...
https://www.omron-ap.co.in/data_pdf/cat/ck3e_ds_e_10_1_csm1054440.pdf
...d the status of communications with the Slaves. Rotary Switch This switch sets the Master’s one-digit hexadecimal unit number. DIP Switch These pins have the following functions: Pin 1: Max. ...
https://www.omron-ap.co.in/data_pdf/cat/compobus_s_q103-e1-07.pdf
...full scale 0.8% full scale 0.5% full scale 0.7% full scale A/D conversion data 16-bit binary (4-digit hexadecimal) Full scale for –10 to 10 V: F448 to 0BB8 Hex Full scale for other ranges: 00...
https://www.omron-ap.co.in/data_pdf/cat/cp1e_p061-e1_17_6_csm2118.pdf
...full scale 0.8% full scale 0.5% full scale 0.7% full scale A/D conversion data 16-bit binary (4-digit hexadecimal) Full scale for –10 to 10 V: F448 to 0BB8 Hex Full scale for other ranges: 00...
https://www.omron-ap.co.in/data_pdf/cat/cp1h_p080-e1_11_13_csm1004100.pdf
...full scale 0.8% full scale 0.5% full scale 0.7% full scale A/D conversion data 16-bit binary (4-digit hexadecimal) Full scale for –10 to 10 V: F448 to 0BB8 Hex Full scale for other ranges: 00...
https://www.omron-ap.co.in/data_pdf/cat/cp1l_p081-e1_10_12_csm1004101.pdf
...% full scale 1% full scale 0.7% full scale 0.9% full scale A/D conversion data 16-bit binary (4-digit hexadecimal) Full scale for –10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 00...
https://www.omron-ap.co.in/data_pdf/cat/cp2e_p145-e1_2_7_csm1074605.pdf
...type setting applies to all 4 inputs. ( 0.3% of indication value or 1 C, whichever is larger) 1 digit max. Indicator Accuracy in Exceptional Cases Input type and temperature range Indicator a...
https://www.omron-ap.co.in/data_pdf/cat/crt1_crt1b_componet_p056-e1_17_10_csm2176.pdf
...) •Mnemonics Instruction length 1 to 7 steps per instruction Ladder instructions Approx. 400 (3-digit function codes) Execution time Basic instructions 0.02 μs min. Special instructions 0.04 ...
https://www.omron-ap.co.in/data_pdf/cat/cs1g_cs1h_cs1w_cs1d_p047-e1_14_15_csm1004120.pdf
.... Unit Number Switch One rotary switch. The unit number of the Unit on the PLC is set in single-digit hexadecimal. Node Address Switches Two rotary switches. The node address of the Unit on t...
https://www.omron-ap.co.in/data_pdf/cat/cs1w-clk_ds_e_5_11_csm1613.pdf
...ber setting switch This rotary switch sets the unit number on the CPU Unit with one hexadecimal digit. Node address setting switches These two rotary switches set the node address for the Eth...
https://www.omron-ap.co.in/data_pdf/cat/cs1w-eip21_eip21s_ds_e_7_9_csm1782.pdf
... the Unit. 100M PER LNK MSG TS RUN HER TX RX 0 0 Unit Number Switch Sets the unit number in one digit hexadecimal. 1 ×161 ×160 Node Number Switches Set the Unit's FINS node number in two digi...
https://www.omron-ap.co.in/data_pdf/cat/cs1w-fln22_ds_e_1_3_csm2178.pdf
... E5AN-H E5EN-H 3-level Display Simultaneously displays set items, such as the PV, SV, and MV. 5-digit Display with high resolution of 0.01°C Auxiliary Outputs • Two • Three Control Output 2 (...
https://www.omron-ap.co.in/data_pdf/cat/e5an-h_e5en-h_ds_e_3_16_csm1377.pdf
...od • 60 ms Auxiliary Outputs • Two Control Output 2 • None • Voltage output (for driving SSR) 5-digit Display with high resolution of 0.01°C • Auto/manual switching • Temperature Controller s...
https://www.omron-ap.co.in/data_pdf/cat/e5cn-h_ds_e_4_12_csm1376.pdf
...61326-1) Thermocouple (See note 1.): (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. Platinum resistance thermometer (See note 2.): (±0.5% of indication value or ±1°C, w...
https://www.omron-ap.co.in/data_pdf/cat/e5cs_ds_e_5_3_csm211.pdf
...× 48 mm E5CWL 48 × 96 mm E5EWL Note: Refer to Precautions on page 9. Main I/O Functions E5EWL 4-digit Display Single Display: E5CSL Dual Display: E5CWL Sensor Inputs • Thermocouple inputs • P...
https://www.omron-ap.co.in/data_pdf/cat/e5csl_e5cwl_e5ewl_h167-e1_1_4_csm2643.pdf