Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 6561 - 6580 of 41742
PDF[9419063-5D] K8AB-PM Measuring & Monitoring Relay ...

... (at 500V) Between electric circuit and case P-P AC200/220/230/240V -PM1 P-N AC115/127/133/139V Input Range P-P AC380/400/415/480V P-N AC219/231/240/277V Input Load Overload Capacity...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k8ab-pm_inst-9419063-5d.pdf

PDF[9419059-7C] K8AB-VS measuring & monitoring relay ...

...to relevant requirements of IEC60947-1 and IEC60947-3, and label them appropriately. 11. For DC input, use a SELV power-supply capable of overcurrent protection. Specifically, a SELV powersup...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k8ab-vs(oldtype)_inst-9419059-7c.pdf

PDF[9419059-7E] K8AB-VS Measuring & Monitoring Relay ...

...erformed by qualified personnel. (4)Do not use this product with circuits that have distor -ted input wave forms. Distortion in wave forms will result in errors. (5)Using this product for...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k8ab-vs_inst-9419059-7e.pdf

PDFInstructions Manual Model 61F-D21T-V1

...for DC power supply. The insulation of SELV power supply must be a double or reinforced between input and output. The output voltage shall be 30Vr.m.s and 42.4V at peak, or use the power supp...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/61f-d21t-v1_inst-0943893-3c.pdf

PDFINSTRUCTION SHEET Precaution for Compliance with U...

...·I/O Source: Isolated Source ·Communication Source: Isolated Source ·Surrounding Air Temp: 55°C Input and output wiring must be in accordance with Class I , Div. 2 wiring methods and in accor...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/grt1-drt(precautionsforulcsastandards)_inst-0675654-3b.pdf

PDFINSTRUCTION SHEET Precaution for Compliance with U...

... 8A over-current protection ·I/O Source: Isolated Source ·Communication Source: Isolated Source Input and output wiring must be in accordance with Class I , Div. 2 wiring methods and in accor...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/grt1series(precautionsforulcsastandards)_inst-0675843-0c.pdf

Safety Precautions of Counters Cautions for Counte...

...alis, or strong acids because they will damage the external finish of the Counter. Separate the input devices, input wiring, and Counter as far as possible from sources of noise and ...

https://www.ia.omron.com/product/cautions/11/safety_precautions.html

Safety Precautions of Solid-state Relays Cautions ...

...tions as well as the load conditions if the user wants to confirm the ratings of specific SSRs. Input Circuit Input-side Connection There is variation in the input impedance...

https://www.ia.omron.com/product/cautions/18/safety_precautions.html

Safety Precautions of Timers Cautions for Timers |...

...lkalis, or strong acids because they will damage the external finish of the Timer. Separate the input devices, input wiring, and product as far as possible from sources of noise and ...

https://www.ia.omron.com/product/cautions/19/safety_precautions.html

Safety Precautions of Power Supplies Cautions for ...

...ngs or cuttings resulting from installation work to enter the Product. Precautions for Safe Use Input Voltage Use a commercial power supply for the power supply voltage input to mode...

https://www.ia.omron.com/product/cautions/22/safety_precautions.html

Safety Precautions of Photomicro Sensors Cautions ...

...ge Output • A Sensor with an open-collector output can be connected to a counter with a voltage input by connecting a resistor between the power source and output. Select a resistor with refe...

https://www.ia.omron.com/product/cautions/24/safety_precautions.html

Safety Precautions of Rotary Encoders Cautions for...

...ay break if the cable is bent. Do not bend a Standard or Robot Cable at low temperature. Others Input to More than One Counter from Encoder (with Voltage Output) To connect multiple identical...

https://www.ia.omron.com/product/cautions/34/safety_precautions.html

Safety Precautions of Proximity Sensors Cautions f...

...kage current flowing in the load, and design the load current so that (leakage current) × (load input impedance) ...

https://www.ia.omron.com/product/cautions/41/safety_precautions.html

Safety Precautions of Photoelectric Sensors Cautio...

...nsor Controller DC Three-wire NPN Output Sensors Reverse operation is possible using the signal input switch on the S3D2. Mounting Attachment to Moving Parts To mount the Photoelectric Sensor...

https://www.ia.omron.com/product/cautions/43/safety_precautions.html

Safety Precautions of Temperature Controllers Caut...

...resistance of the three lead wires the same. Make sure that the Temperature Sensor type and the input type of the Temperature Controller are the same. There are two types of platinum resistan...

https://www.ia.omron.com/product/cautions/53/safety_precautions.html

F3SJ Series Safety Light Curtain/Features | OMRON ...

... LED will light to indicate the status or possible error. Communication error (EASY/BASIC type) Input error (BASIC type) Industry First! Error indication while muting is in progress. The days...

https://www.ia.omron.com/products/family/1581/application.html

PDFPrecaution for Compliance with UL Standards and CS...

...t Rated 55䉝surrounding air temperature z Compliance with Class I Division 2 Hazardous Location: Input and output wiring must be in accordance with Class I, Div. 2 wiring methods and in accor...

https://www.omron.com.tw/data_pdf/closed/mnu/cj1w-nc_71_-nc471_-ncf71(-ma),cs1w-nc_71_-ncf71(precautionsforulcsastandards)_inst-1148685-6b.pdf

OMRON Releases Machine Safeguarding Units | OMRON ...

...e operation of a hazard and monitor its speed of rotation. The G9SX-LM is also equipped with an input terminal for an enabling grip switch, and can monitor whether the switch is being pressed...

https://www.ia.omron.com/new/information/2008/06/002.html

Machine Automation Controllers - Product Category ...

...omation platform integrates control, information, and safety CPU Units EtherNet/IP Unit Digital Input / Output Unit Analog Input / Output Unit Temperature Control Unit / Temperature ...

https://www.omron-ap.com/products/category/automation-systems/machine-automation-controllers/index.html

S8VK-C 電源供應器 (經濟型)(60/120/240/480-W型)/CAD | OMRON ...

...尺寸 型錄/操作手冊/CAD/軟體 型錄 CAD 登入/註冊 後,您可下載CAD圖檔。 產品型號 產品概述 CAD圖檔下載 S8VK-C06024 Single Phase 60W , Input 100 to 240 VAC / 90 to 350 VDC , Output 24V2.5A 2D / 3D...

https://www.omron.com.tw/products/family/3201/download/cad.html

Results 6561 - 6580 of 41742

Select Country in