Site Search | Product Search | IA Global Search |
...5 V 26 V CS1 Special analog I/O Units Analog Output Units 4 out- puts Set sepa- rately for each input 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 V to 10 V, 4 to 20 mA 1/4,000 1 ms/ point Re- movable ...
...5V 24V CS1 Special I/O Units Isolated- type Analog Output Unit 4 inputs Set separately for each input 4 to 20 mA, 1 to 5 V 100 ms/ 4 inputs Removable terminal block 1 0.15 0.16 CS1W-PMV01 UC1...
...Analog Output Unit: Analog output values for each output Analog Output Unit to CPU Unit: Answer input values for each output, output disconnection DM Area words allocated to Special I/O Units...
https://www.omron-ap.co.nz/products/family/1669/specification.html
...ensions Catalog / Manual / CAD / Software last update: November 5, 2013 Temperature Controllers Input Thermocouple K (CA) Chromel vs. alumel Standard scale (°C) 0 to 200 0 to 300 0 to 400 0 t...
...Hz Operating voltage range 90% to 110% of rated supply voltage Power consumption Approx. 3.6 VA Input Thermocouple (with sensor burnout detection circuit), platinum resistance thermometer, or...
https://www.omron-ap.co.nz/products/family/167/specification.html
... tion 5 V 26 V CS1 Special analog I/O Units Analog I/O Units 4 inputs Set sepa- rately for each input 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 V to 10 V, 4 to 20 mA 1/4,000 1 ms/ point Re- movable ...
...I/O Unit Analog output Peak value hold Conversion Enable Bit Analog I/O Unit to CPU Unit Analog input Input disconnection detection Alarm flags Internal Special I/O Unit DM Area (D20...
https://www.omron-ap.co.nz/products/family/1670/specification.html
...OMRON representative for the conditions under which the standards were met. Isolated-type Pulse Input Unit Unit type Product name Input points External connection No. of unit numbers...
...sation) Current consumption Name Model Current consumption (power) 5 V 26 V Isolated-type Pulse Input Unit CS1W-PPS01 0.20 A (1.00 W) 0.16 A (4.2 W) (Reference) Maximum current and total powe...
https://www.omron-ap.co.nz/products/family/1671/specification.html
...ailure. Ethernet (LAN) ports One port (10/100Base-TX, RJ45 Modular Connector) UPS power failure input None (UPS connected to COMM port.) Settings and operation Unit number switch (UNIT) Rotar...
https://www.omron-ap.co.nz/products/family/1732/specification.html
...and OPE3) NPN open-collector output, 30 VDC, 20 mA max. Residual voltage: 1.2 V max. Bank shift input, zero reset input, timing input, reset input ON: Short-circuit...
https://www.omron-ap.co.nz/products/family/1736/specification.html
...1 and 2 Con- trol out- puts 3 and 4 Aux- iliary output Functions Com- muni- cations func- tions Input type Ter- minal Model Heat- er burn- out alarm E- vent in- puts Basic Unit (tem- perature...
...110% of rated voltage Power consumption 3 W max. (at maximum load) 2.5 W max. (at maximum load) Input * Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII ES1B Infrared Thermosensor: 10 to...
https://www.omron-ap.co.nz/products/family/1757/specification.html
...istics Model S8M-CP04 S8M-CP04-R S8M-CP04-RS Number of branches 4 I/O char- acter- istics Rated input voltage 24 VDC (19.2 to 26.4 VDC) Allowable input current 17.0 A max. 16.0 A max...
https://www.omron-ap.co.nz/products/family/1768/specification.html
...ts: 1 MHz, 2 axes 100 kHz, 2 axes DC power supply Transistor output (sinking) 12 + line- driver input, 2 axes 8 + line- driver output, 2 axes CP1H-Y20DT-D Note: 1. CP1H PLCs are supported by ...
...cyclic tasks and 256 interrupt tasks) Scheduled interrupt tasks 1 (interrupt task No. 2, fixed) Input interrupt tasks 8 (interrupt task No. 140 to 147, fixed) 6 (interrupt task No. 140 to 145...
https://www.omron-ap.co.nz/products/family/1778/specification.html
...s:256 inputs and 256 outputs (512 I/O points total) Maximum number of nodes Word Slave Units:64 input nodes and 64 output nodes Bit Slave Units:128 input nodes and 128 output nodes R...
https://www.omron-ap.co.nz/products/family/1779/specification.html
...s:256 inputs and 256 outputs (512 I/O points total) Maximum number of nodes Word Slave Units:64 input nodes and 64 output nodes Bit Slave Units:128 input nodes and 128 output nodes R...
https://www.omron-ap.co.nz/products/family/1781/specification.html
...ble. They can be combined in various ways for flexible I/O capacity expansion. Model I/O points Input capacity Output capacity XWT-ID08 8 DC inputs (NPN) 8 0 XWT-ID08-1 8 DC inputs (PNP) 8 0 ...
...on) Terminal block screws tightening torque M3 wiring screws: 0.5 Nm M3 mounting screws: 0.5 Nm Input Section Specifications Eight-point Input Units (2-tier Terminal Block) Item Spec...
https://www.omron-ap.co.nz/products/family/1822/specification.html