Results 9881 - 9900 of 41879
CRT1B-[]D02S(-1) Bit Slave Units with e-CON Connec...

...n for the CRT1-VAD04S. *2 Applicable only to Slaves to which screw terminal blocks are mounted. Input Section Specifications Item Specification Model CRT1B-ID02S CRT1B-ID02S-1 I/O capacity 2 ...

https://www.omron-ap.co.nz/products/family/1823/specification.html

CRT1-AD04 / DA02 Analog I/O Slave Units/Specificat...

...n for the CRT1-VAD04S. *2 Applicable only to Slaves to which screw terminal blocks are mounted. Input Section Specifications Item Specification Voltage input Current input M...

https://www.omron-ap.co.nz/products/family/1825/specification.html

ZN-A Air Clean Units/Specifications | OMRON Indust...

...ton operation Settable by serial (RS-422 or RS-485 *1) communications Settable by ON/OFF signal input (3 levels) *2 Running noise Airflow level 3: 53 dB (typical) Airflow level 3: 53 dB (typi...

https://www.omron-ap.co.nz/products/family/1828/specification.html

ZN-PD Air Particle Sensor/Specifications | OMRON I...

...e note.) NPN open-collector outputs, 30 VDC, 30 mA max., Residual voltage: 1.2 V max. --- Reset input (See note.) ON: Short-circuited with 0-V terminal or 1.5 V or less, OFF: Open --- Functio...

https://www.omron-ap.co.nz/products/family/1830/specification.html

D40A / G9SX-NS Compact Non-Contact Door Switch/Non...

...or Switch Controllers G9SX-NS[] Safety outputs *1 Auxiliary outputs *3 Logical AND con- nection input Logical AND con- nection output Max. OFF delay time *4 Rated voltage Terminal block type ...

https://www.omron-ap.co.nz/products/family/1832/lineup.html

D40A / G9SX-NS Compact Non-Contact Door Switch/Non...

...hing Rubber Cover PBT resin (UL94V-0) G9SX-NS Non-contact Door Switch Controllers Ratings Power input Model G9SX-NS202-[] G9SX-NSA222-T03-[] G9SX-EX-[] Rated supply voltage 24 V DC Operating ...

https://www.omron-ap.co.nz/products/family/1832/specification.html

V680 Series RFID System/Specifications | OMRON Ind...

... VDC (-15% to +10%) 15 W max., 0.8 A max. Communications Specifications RS-232C, RS-422, RS-485 Input Specifications (Input voltage) RST, TRG1, and TRG2 24 VDC (+10% to -15%, includi...

https://www.omron-ap.co.nz/products/family/1863/specification.html

ZUV-C20H / 30H Smart Curing System (Standard model...

...1 should be selected.       AC adapter and AC cord is not supplied with it, but the cord for DC input is supplied. *4. In the case that you use ZUV-C30H in other than Japan, please connect DC...

https://www.omron-ap.co.nz/products/family/1876/specification.html

G9SX-GS Safety Guard Switching Unit/Specifications...

...tions Dimensions Catalog / Manual / CAD / Software last update: December 23, 2024 Ratings Power Input Model G9SX-GS226-T15-[] G9SX-EX-[] Rated supply voltage 24 VDC Operating voltage range -1...

https://www.omron-ap.co.nz/products/family/1882/specification.html

CP1L CP series CP1L CPU Unit/Lineup | OMRON Indust...

...on Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *1 *2 *4 CP1W-CIF41 Analog Input Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 2 analog inpu...

https://www.omron-ap.co.nz/products/family/1916/lineup.html

CP1L CP series CP1L CPU Unit/Specifications | OMRO...

...cyclic tasks and 256 interrupt tasks) Scheduled interrupt tasks 1 (interrupt task No. 2, fixed) Input interrupt tasks 6 (interrupt task No. 140 to 145, fixed) (High-speed counter interrupts a...

https://www.omron-ap.co.nz/products/family/1916/specification.html

ZX-GT Smart Sensor Wide Laser Beam Measurement Sen...

...er alarm indicator (red) Indicators (receiver) Optical axis setting indicator (green) Laser OFF input/sync input ON: Short-circuited with 0 V or 1.5 V max. OFF: Open (leakage current...

https://www.omron-ap.co.nz/products/family/1918/specification.html

CRT1-[]D08TA(-1) / []D16TA(-1) / []D08TAH(-1) / []...

...n for the CRT1-VAD04S. *2 Applicable only to Slaves to which screw terminal blocks are mounted. Input Section Specifications Eight-point Input Units (3-tier Terminal Block) Item Spec...

https://www.omron-ap.co.nz/products/family/1919/specification.html

XWT-[]D08(-1) / []D16(-1) Expansion Units/Specific...

...on for the CRT1-VAD04S. *2 Applicable only to Slaves to which screw terminal blocks are mounted Input Section Specifications Item Specification Model XWT-ID08 XWT-ID08-1 XWT-ID16 XWT-ID16-1 I...

https://www.omron-ap.co.nz/products/family/1920/specification.html

G3PF Solid State Relays with Built-in Current Tran...

...eup Specifications Dimensions Catalog / Manual / CAD / Software last update: September 24, 2012 Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicabl...

https://www.omron-ap.co.nz/products/family/1924/lineup.html

G3PF Solid State Relays with Built-in Current Tran...

...tput form NPN open collector (ON when error is detected.) Minimum load current 0.1 mA Operation Input Input method Voltage input Rated input voltage 12 to 24 VDC Op...

https://www.omron-ap.co.nz/products/family/1924/specification.html

H3CR-A Solid-state Multi-functional Timers/Lineup ...

...atalog / Manual / CAD / Software last update: April 1, 2020 11-pin Models Output Supply voltage Input type Time range Operating mode *2 Model *1 Contact 100 to 240 VAC (50/60 Hz)/ 100 to 125 ...

https://www.omron-ap.co.nz/products/family/193/lineup.html

H3CR-A Solid-state Multi-functional Timers/Specifi...

... start) E: Interval (power supply start) J: One-shot (power supply start) Pin type 11-pin 8-pin Input type No-voltage input Voltage input --- Time-limit output type H3CR-A/-...

https://www.omron-ap.co.nz/products/family/193/specification.html

H7BX Multifunction Counter (DIN 72 × 72)/Specifica...

...ls Degree of protection Compliant with IEC IP54 for panel surface only, Certified for UL Type 1 Input signals CP1, CP2, reset 1, reset 2, key protection Counter Max. counting speed 30 Hz or 5...

https://www.omron-ap.co.nz/products/family/1931/specification.html

F3W-E Picking Sensor/Specifications | OMRON Indust...

.... (Residual voltage: 1.8 V max.) Dark-ON or Light-ON (selectable) Picking instruction indicator input Relay or open collector input NPN input Indicator ON: Input vo...

https://www.omron-ap.co.nz/products/family/1932/specification.html