PDF1 CSM_E6J-A_DS_TW_3_2 超小型旋轉編碼器(外徑φ20)/絕對型E6J-A

...時) 輸出時上微分/下微分時間2μs以下(纜線長度:1m、負載電流:4mA) 最高響應頻率*2 20kHz 邏輯負邏輯(H=「0」、L=「1」) 旋轉方向CW方向(從軸心處來看為向右旋轉),輸出代碼增加啟動扭力1mN·m...

https://www.omron.com.tw/data_pdf/cat/e6j-a_ds_tw_3_2.pdf

PDF1 CSM_E6J-C_DS_TW_4_2 超小型旋轉編碼器(外徑φ20)/增量型E6J-C

...下(纜線長度:1m、負載電流:20mA) 最高響應頻率*2 100kHz(執行Z相復歸時為50kHz) 輸出相位差A相、B相的相位差90°±45° 旋轉方向CW方向(從軸心處來看向右旋轉),A相先進行啟動扭力1mN·m以下慣性力矩 ...

https://www.omron.com.tw/data_pdf/cat/e6j-c_ds_tw_4_2.pdf

PDFCSM_M22_DS_E_4_4 1 Indicator (Cylindrical 22/25-di...

...ance Color of Display Model Square (Projection) Red M22-CR Green M22-CG Yellow M22-CY White M22-CW Blue M22-CA Operating voltage 6 VAC/VDC 12 VAC/VDC 24 VAC/VDC Appearance AC/DC LED light Mod...

https://www.omron.com.tw/data_pdf/cat/m22_ds_e_4_4_csm610.pdf

PDFCSM_M22_DS_TW_3_7 1 指示燈(圓形φ22/25)M22

...關共用。 請參閱A22型。 密封性IP65 形狀操作部位的顏色型號正方形(凸出形)紅色M22-CR 綠色M22-CG 黃色M22-CY 白色M22-CW 藍色M22-CA 使用電壓AC/DC6V AC/DC12V AC/DC24V 形狀發光顏色型號型號型號 AC/ ...

https://www.omron.com.tw/data_pdf/cat/m22_ds_tw_3_7.pdf

PDFCSM_NY5__-1_NY5__-5_DS_TW_3_13

...刀具長度的刀具前端軌跡補償 M代碼輸出與重置M代碼透過輸出及重置M代碼與序列控制程式連鎖的功能主軸 CW/CCW/停止於速度控制模式中輸出/停止速度指令的功能定向組成反饋迴路使指定相位的主軸停止的功能...

https://www.omron.com.tw/data_pdf/cat/ny5__-1_ny5__-5_ds_tw_3_13-2.pdf

PDFAdvanced Functionality in a Super Compact Design

...esonance. •Compatible with 90°Phase Difference Input Command Pulses In addition to conventional CW/CCW inputs (2 pulses) and SIGN/PULS inputs (1 pulse), the SMARTSTEP 2 supports 90°phase diff...

https://www.omron.com.tw/data_pdf/cat/r88m-g_r7d-bp_i813-e1_9_15_csm2685.pdf

PDF在超小體積中凝聚優異的性能與效能 AC伺服馬達/驅動器 SMARTSTEP2

...適合的增益。 另外,透過適配濾波器,可自動抑制因共振產生的振動。 •亦支援指令脈衝輸入的90°相位差輸入除了既有的CW/CCW(2脈衝輸入方式)、SIGN/PULS (1脈衝輸入方式),亦支援90°相位差輸入。 編碼器...

https://www.omron.com.tw/data_pdf/cat/r88m-g_r7d-bp_sbce-051_tw_9_18.pdf

PDFCSM_XW2B_for_MC_DS_TW_1_2 1 運動控制模組專用端子台XW2B

...地14 7共點DC GND 24V輸入接地14 8 YSTOP YSTOP Y軸立即停止輸入7 9IN2IN2通用輸入2 9 10+24V+24V 24V輸入1 11 XCWL XCWL X軸CW極限輸入2 12 XCCWL XCCWL X軸CCW極限輸入4 13 XORG XORG X軸原點近接輸入1...

https://www.omron.com.tw/data_pdf/cat/xw2b_for_mc_ds_tw_1_2.pdf

PDF©OMRON Corporation 2002 All Rights Reserved.©OMRON...

... max. 残留電圧:0.4V以下 (シンク電流35mA時) シンク電流:35mA max. 残留電圧:0.4V以下 (シンク電流35mA時) 20kHz 負論理 CW(シャフトから見て右回転)で出力コード増加コード引き出しタイプコネク...

https://www.omron.com.tw/data_pdf/mnu/e6c3-a_inst-6903887-0h.pdf

PDFThank you for choosing this OMNUC FND-X-series pro...

...ARCH 9 20 22 READY 24 ORGSTP 19 OGND 21 25 T.COM 23 S.COM 6 RESET 5START 26 RUNON 28 ALM 27 INP CW limit in- put RUN command Alarm reset Origin proximity Start CCW limit input Origin search R...

https://www.omron.com.tw/data_pdf/mnu/i524-04_fnd-x__x_-srt.pdf

PDFUSER’S MANUAL Model R88A-NCW152-DRT

...wed from the motor output shaft. (Standard setting) 1 Forward rotation is defined as clockwise (CW) rotation as viewed from the motor output shaft. (Reverse Rotation Mode) Position data from ...

https://www.omron.com.tw/data_pdf/mnu/i538-e1-01_r88a_ncw152_drt.pdf

PDFCat. No. I561-E1-08 USER’S MANUAL

...nance. Compatible with Command Pulse of 90Phase Difference Inputs In addition to conventional CW/CCW inputs (2 pulse inputs) and SIGN/PULS inputs (1 pulse input), the SMARTSTEP 2 supports 9...

https://www.omron.com.tw/data_pdf/mnu/i561-e1-08_r88m-g_r7d-bp.pdf

PDFCat. No. I571-E1-08 USER’S MANUAL

...ire input pins that are not being used. 2 kΩ 120Ω 20 kΩ 2kΩ 220Ω 5 2 6 Operation command 44 45 +CWCW +CCW −CCW +CWLD −CWLD Reverse pulse Forward pulse BKIR Brake interlock Alarm ou...

https://www.omron.com.tw/data_pdf/mnu/i571-e1-08_r88m-k_r88d-kt.pdf

PDFCat. No. I572-E1-04 USER’S MANUAL

...irection and the motor rotation direction. 0: A forward direction command sets the direction to CW as viewed from the shaft end. 1: A forward direction command sets the direction to CCW as vi...

https://www.omron.com.tw/data_pdf/mnu/i572-e1-04_r88m-k__r88d-kn_-ml2.pdf

PDFLD-60/90 Platform User's Manual

... operation. 75% 100% 25% 50% Left Side Light Disc Right Side Light Disc State of Charge 0 to 90 cw 0 to 270 ccw 25% 0 to 180 cw 0 to 180 ccw 50% 0 to 270 cw 0 to 90 ccw 75% ...

https://www.omron.com.tw/data_pdf/mnu/i611-e-08_ld_platform.pdf

PDFI612-E-03 LD Cart Transporter User’s Guide

...n blinks green (red if E-Stopped). 75% 100% 25% 50% Left Side Right Side State of Charge 0 to90 cw 0 to270 ccw 25% 0 to180 cw 0 to180 ccw 50% 0 to270 cw 0 to90 ccw 75% full ...

https://www.omron.com.tw/data_pdf/mnu/i612-e-03_ld_cart_transporter.pdf

PDFLD-250 Platform User's Manual LD-250

... operation. 75% 100% 25% 50% Left Side Light Disc Right Side Light Disc State of Charge 0 to 90 cw 0 to 270 ccw 25% 0 to 180 cw 0 to 180 ccw 50% 0 to 270 cw 0 to 90 ccw 75% ...

https://www.omron.com.tw/data_pdf/mnu/i642-e-07_ld-250.pdf

PDFHD-1500 Platform User's Manual I645-E-04

...latform User's Manual (I645) Left Side Light Disc Right Side Light Disc State of Charge 0 to 90 cw 0 to 270 ccw 25% 0 to 180 cw 0 to 180 ccw 50% 0 to 270 cw 0 to 90 ccw 75% ...

https://www.omron.com.tw/data_pdf/mnu/i645-e-04_hd-1500.pdf

PDFAMR (Autonomous Mobile Robot) MD-series Platform

...latform User's Manual (I681) Left Side Light Disc Right Side Light Disc State of Charge 0 to 90 cw 0 to 270 ccw 25% 0 to 180 cw 0 to 180 ccw 50% 0 to 270 cw 0 to 90 ccw 75% ...

https://www.omron.com.tw/data_pdf/mnu/i681-e-02_md-650.pdf

PDFAC Servomotor/Servo Drives Replace Guide

...osition control. SS2 series G5 series Terminal No. Symbol Name Terminal No. Symbol Name CN1 22 +CW/PULS/FA Reverse Pulses Input, Feed Pulses Input, or 90°Phase Difference Pulses (Phase A) CN1...

https://www.omron.com.tw/data_pdf/mnu/i879-e1-01_smartstep2series_to_g5series.pdf