Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 1441 - 1460 of 2019
PDFCat. No. W442-E1-01 SYSMAC REFERENCE MANUAL

...(006C) 1 word 14 CCW Software Limit m+25 (0019) m+53 (0035) m+81 (0051) m+109 (006D) 2 words 15 CW Software Limit m+27 (001B) m+55 (0037) m+83 (0053) m+111 (006F) 2 words 16 Initial Pulse Des...

https://www.omron.com.tw/data_pdf/mnu/w442-e1-01_fb_library.pdf

PDFCat. No. W450-TW5-01 SYSMAC CP系列

...଻ႀȃ؏໌଻ႀ้پ໌՗ଽഀȃଽ ᆠ࡙ޟۡ՝Ȅ രຝҢپ௡ڙؐএᒯюᘈޟࡾхȂџоؚۡ၎ᒯюޟ᜸࠮࢐֏ғலᒯюȃ ૕ፐᒯюܖPWMᒯюȄ ׇᐌޟ૕ፐᒯюђ૖ (ܚԤᐠ࠮) ᒵᐅCW/CCW૕ፐᒯюܖ૕ፐёПөᒯюհ࣏૕ፐᒯю џоᒵᐅᎌ࿋ޟ૕ፐᒯюپ଩ӫ଻ႀ៮ଢ଼Ꮲޟ૕ፐᒯΣೣਿȄ ٺҢՌଢ଼Пө೩ۡȂо๘ᄇ৴኿فಛ໌՗ᙏܾۡ՝ ӵ๘ᄇ৴኿فಛޟհཾϛ(һ։࿋নᘈϐင࡚...

https://www.omron.com.tw/data_pdf/mnu/w450-tw5-01_cp1h.pdf

PDFUSER’S MANUAL Cat. No. W480-E1-09

...fine origin operation Do not use. Do not use. When power is turned ON Use. 1-1 Search Direction CW CW At start of operation CCW 1-2 Detection Method Method 0 Method 0 At start of ope...

https://www.omron.com.tw/data_pdf/mnu/w480-e1-09_cp1e.pdf

PDFEtherCAT Remote I/O Terminal GX-series

...ollowing types for the encoder directions of an Encoder Input Slave Unit. •Forward direction at CW (clockwise rotation seen from the shaft of the connected encoder) •Forward direction at CCW ...

https://www.omron.com.tw/data_pdf/mnu/w488-e1-11_gx_xwt-id_od.pdf

PDFSysmac Library User’s Manual for MC Command Table ...

...xecutes circular interpolation (border point/relative movement). Circular interpolation (Center/CW/ABS) 16#0310 Executes circular interpolation (center/CW direction/absolute travel)....

https://www.omron.com.tw/data_pdf/mnu/w545-e1-05_sysmac-xr002.pdf

PDFIndustrial PC Platform NY-series

...ions 9-56 NY-series Industrial Panel PC / Industrial Box PC Motion Control User's Manual (W559) CW CCW CW : Clockwise rotation CCW : Counterclockwise rotation Y coordinate X coordina...

https://www.omron.com.tw/data_pdf/mnu/w559-e1-07_ny532_ny512.pdf

PDFSysmac Library User’s Manual for Packaging Machine...

...es •The motor rotation direction when viewing the shaft from the load side is called clockwise (CW) or counterclockwise (CCW). For details, refer to the AC Servomotors/Servo Drivers 1S-series...

https://www.omron.com.tw/data_pdf/mnu/w572-e1-04_sysmac-xr012.pdf

PDFMachine Automation Controller NX-series

...l (Cat. No. W508). 6-6-3 Circular Interpolation 6-6-4 Axes Group Cyclic Synchronous Positioning CW CCW CW : Clockwise rotation CCW : Counterclockwise rotation Y coordinate X coordina...

https://www.omron.com.tw/data_pdf/mnu/w579-e1-06_nx1p2.pdf

PDFUSER’S MANUAL Cat. No. W614-E1-03

...fine origin operation Do not use. Do not use. When power is turned ON Use. 1-1 Search Direction CW CW At start of operation CCW 1-2 Detection Method Method 0 Method 0 At start of ope...

https://www.omron.com.tw/data_pdf/mnu/w614-e1-03_cp2e.pdf

PDFH8PS Cam Positioner OPERATION MANUAL

....2 16-/32-output Models (H8PS-16…/-32…) ORIGIN CHECK CAM STEP CLEAR ANGLE ADV WRITE DO NOT USE. CW CCW PLS/R ANG DSPL CAM STEP 1. CHECK key 2. CAM keys 3. STEP keys 4. ON/OFF key 5. WRITE key...

https://www.omron.com.tw/data_pdf/mnu/z199-e1-02_h8ps.pdf

PDFRFID System V680 Series Hand-held Reader Writer

... CONTROL MD ST S/L OVERWRITE COUNT CONTROL MD S CALCULATION WRITE --- --- --- CALCULATION WRITE CW A/S ID CODE READ ID ST H ID CODE READ ID H READ WITH ERROR CORRECTION QR ST A/H --- --- --- ...

https://www.omron.com.tw/data_pdf/mnu/z272-e1-09_v680-chud_ch1d.pdf

PDFPushbutton Switch (Cylindrical 22/25-dia.)

...-NO Illumination color --- A22L-C@-24A-11M A22L-C@-24A-11A A22L-C@-24A-20M A22L-C@-24A-20A A22L-CW-T1-10M A22L-C@-T2-10M --A22L-C@-T2-01M A22L-C@-T1-11M A22L-C@-T2-11M A22L-C@-T1-20M A22L-CG-...

https://www.omron.com.vn/data_pdf/cat/a22_ds_e_8_12_csm607.pdf

PDFCJ series Position Control Units

... personal computer hard disk or floppy disk. Inputs Prepare the following inputs for each axis: CW and CCW limit input signals, origin proximity input signal, origin input signal, emergency s...

https://www.omron.com.vn/data_pdf/cat/cj1w-nc__3_ds_e_8_9_csm1849.pdf

PDFCJ-series CJ2M CPU Units, Pulse I/O Modules

... Module model.) 12 max. (6 per Pulse I/O Module) 4 max. (2 per Pulse I/O Module) Output method: CW/CCW or pulse + direction (The method is determined by the I/O wiring and the instructions us...

https://www.omron.com.vn/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf

PDFCP series CP1H CPU Unit CP1H-X@@D@-@/CP1H-Y@@D@-@

... outputs) Line-driver inputs: Two axes for phases A, B, and Z Line-driver outputs: Two axes for CW and CCW CP1H Type Item Models CP1H-X CPU Units CP1H-XA@@@-@ CP1H-X@@@-@ CP1H-Y CPU Units CP1...

https://www.omron.com.vn/data_pdf/cat/cp1h_p080-e1_11_13_csm1004100.pdf

PDFCP series CP1L CPU Unit CP1L-EM@@D@-D/CP1L-EL@@D@-...

...r S-curve acceleration and deceleration (Duty ratio: 50% fixed) 2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction) Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%) ...

https://www.omron.com.vn/data_pdf/cat/cp1l_p081-e1_10_12_csm1004101.pdf

PDFGeneral-purpose Limit Switch D4A-@N CSM_D4A-_N_DS_...

...lay window. Roller Lever Switch The head of the side rotary type can be converted in seconds to CW, CCW, or both-way operation. Follow the procedures on the right hand side for conversion (no...

https://www.omron.com.vn/data_pdf/cat/d4a-_n_ds_e_4_6_csm584.pdf

PDFSafety Limit Switch D4B-@N CSM_D4B-_N_DS_E_10_12

... the lever can be easily changed without using any tools. It can be set to clockwise operation (CW) or counterclockwise (CCW) operation. Use the procedure given at the right to change the ope...

https://www.omron.com.vn/data_pdf/cat/d4b-_n_ds_e_10_12_csm1251.pdf

PDFDirect Discrimination Unit E63-WF CSM_E63-WF_DS_E_...

.... Relation between Inputs (phase A and phase B) and Outputs (COUNTS, UP/DOWN) Encoder direction CW CCW CW CCW CW CCW CW CCW CW ON Phase A OFF IN ON Phase B...

https://www.omron.com.vn/data_pdf/cat/e63-wf_ds_e_4_4_csm489.pdf

PDFIncremental 25-mm-dia. Rotary Encoder

...N and the OFFs mean that the output transistor is OFF. Output transistor Direction of rotation: CW (as viewed from end of shaft) T(360˚) Brown Vcc E6A2-C@@3C: +5 to 12 V E6A2-C@@5C: +12 to 24...

https://www.omron.com.vn/data_pdf/cat/e6a2-c_ds_e_8_2_csm490.pdf

Results 1441 - 1460 of 2019

Select Country in