IAグローバル検索 |
...r phases Model Rated current Inductance Weight R88D-GTA5L Single- phase 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg R88D-GT01L 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg R88D-GT02L 3G3A...
https://www.fa.omron.com.cn/data_pdf/mnu/i562-e1-09_r88m-g__r88d-gt_.pdf
...ed current Inductance Weight Reactor type R88D-GNA5L-ML2 R88D-GN01H-ML2 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg Single- phase R88D-GN01L-ML2 R88D-GN02H-ML2 3G3AX-DL2004 3.2 A 10.7 ...
https://www.fa.omron.com.cn/data_pdf/mnu/i566-e1-07_r88m-g_r88d-gn_-ml2.pdf
...er phases Model Rated current Inductance Weight R88D-KTA5L Single-phase 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg R88D-KT01L 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg R88D-KT02L 3G3A...
https://www.fa.omron.com.cn/data_pdf/mnu/i571-e1-08_r88m-k_r88d-kt.pdf
...ases Model Rated current Inductance Weight R88D-KNA5L-ML2 Single- phase 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg R88D-KN01L-ML2 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg R88D-KN02L-...
https://www.fa.omron.com.cn/data_pdf/mnu/i572-e1-04_r88m-k__r88d-kn_-ml2.pdf
...rent Inductance Weight Reactor type R88D-KP01H (For single-phase input) 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg DC reactor R88D-KP02H (For single-phase input) 3G3AX-DL2004 3.2 A 10.7 ...
https://www.fa.omron.com.cn/data_pdf/mnu/i584-e1-02_r88d-ke__r88m-kp_.pdf
...止 H221第二电机参数R2 视容量而定禁止禁止 H022第一电机参数L 0.01~99.99 100.0~655.3 视容量而定禁止禁止 mH H222第二电机参数L 视容量而定禁止禁止 H023第一电机参数Io 0.01~99.99 100.0~655.3 视容...
...28µsec typical (hardware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤Vdemag≤(+V - 45) DC short circuit current limit 0.7 A≤ILIM≤2.5 A Peak short circ...
https://www.fa.omron.com.cn/data_pdf/mnu/i591-e-05_cobra_350.pdf
...ion Parameter Value ware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65)≤ Vdemag≤(+V - 45) DC short circuit current limit 0.7 A≤ILIM≤2.5 A Peak short circ...
https://www.fa.omron.com.cn/data_pdf/mnu/i596-e-08_hornet565.pdf
...Model Model Rated current Inductance (0% to 20%) 200 VAC R88D-1SN01H-ECT R88A-PD2002 1.6 A 21.4 mH R88D-1SN02H-ECT R88D-1SN04H-ECT R88A-PD2004 3.2 A 10.7 mH R88D-1SN08H-ECT R88A-PD20...
https://www.fa.omron.com.cn/data_pdf/mnu/i619-e1-01_1s series.pdf
...),80μsec(典型值) (仅限硬件) 关闭响应时间60μsec(最大值),28μsec(典型值) (仅限硬件) 电感负载关闭时的输出电压 (Iout = 0.5 A,负载= 1 mH) (+V - 65)≤Vdemag≤(+V - 45) DC短路电流限...
...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 Belt Encoder Specifications Specifications for the XBELTIO connections are provided be...
https://www.fa.omron.com.cn/data_pdf/mnu/i658-e-08_i4-350l_450l_550l.pdf
...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 Belt Encoder Specifications Specifications for the XBELTIO connections are provided be...
https://www.fa.omron.com.cn/data_pdf/mnu/i659-e-01_i4-350l_450l_550l.pdf
...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 TIO Specifications Specifications for the TIO circuits are provided below. Type Item S...
https://www.fa.omron.com.cn/data_pdf/mnu/i660-e-04_i4-650h_750h_850h.pdf
...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 TIO Specifications Specifications for the TIO circuits are provided below. Type Item S...
...t pos- sible 403B 81 3B0A Async. Motor constant L, 1st-motor Hb114 RW 1 to 1000000000 0.000001 (mH) Not pos- sible 403B 83 3B0C Async. Motor constant Io, 1st-motor Hb116 RW 1 to 1000000 0.01 ...
https://www.fa.omron.com.cn/data_pdf/mnu/i663-e1-02_3g3ax-rx2-ect.pdf
...型值) (仅限硬件) 关闭响应时间60µsec(最大值),28µsec(典型值) (仅限硬件) 电感负载关闭时的输出电压 (Iout = 0.5 A,负载= 1 mH) (+V - 65)≤Vdemag≤(+V - 45) DC短路电流限制0.7 A≤ILIM≤2...
https://www.fa.omron.com.cn/data_pdf/mnu/ix4 650 h_hs&800 h_hs_I656-cn5-01-220211.pdf
...ot Model Condition Vertical moment MV (Nm) Force in vertical direction FV (N) Horizontal moment MH (Nm) Force in horizontal direction FH (N) TM25S Series During stillness 890 1020 0 0 During ...
https://www.fa.omron.com.cn/data_pdf/mnu/m104-e-03_tm25s.pdf
... 10 msec A8 fault Phase short to IPM OFF < 3µsec AC fault Current loop response time < 1 msec 1 mH 3-Ph brushless Motor Y-winding Dynamic brake relay response time ...
https://www.fa.omron.com.cn/data_pdf/mnu/o050-e1-05_ck3a-g___l.pdf
...略,因力逆位位くY在先符号十六遺制数値違算吋有作用。 5-20-2二遊制減法指金-SBB{51) 操作数数据区域梯形符号 Mh被減数字(二遊制) IR,SR,AR,DM,HR,TC,LR,# Su滅数字(二遺制) IR,SR,AR,DM,HR,TC,LR,# R:拮...
https://www.fa.omron.com.cn/data_pdf/mnu/oez-zcp97201a_c200hx_c200hg_c200he.pdf
...机器人造成损坏。 图12:TM机器人的力矩和方向说明型号状态垂直力矩 MV(Nm) 垂直方向上的力 FV(N) 水平力矩 MH(Nm) 水平方向上的力 FH(N) TM25S系列静止状态下890 1020 0 0 加速或减速期间1680 143...
https://www.fa.omron.com.cn/data_pdf/mnu/tm25s_m104-cn5-02.pdf