IAグローバル検索 |
...G70D Relay Terminal and not the G6D Relay itself. Coil Ratings (per G6D Relay) Rated voltage 24 V DC Rated current 10.5 mA Coil resistance 2,880 Ω Must-operate voltage 70% max. of rated volta...
https://www.ia.omron.com/products/family/863/specification.html
... 4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A). 5. The values in parentheses are for the G6B-4FB1ND and G6B-...
https://www.ia.omron.com/products/family/901/specification.html
...ut impedance Rated current G3S4-A, G3S4-A1 G3S4-D, G3S4-D1 G3S4-A, G3S4-A1 G3S4-D, G3S4-D1 DC 5 V 4 to 6 VDC 4 VDC max. 1 VDC min. 440 Ω ±20% 550 Ω ±20% 19.2 mA±20% 15.8 mA±20% 12 V ...
https://www.ia.omron.com/products/family/902/specification.html
...ent (mA) Resistance (Ω) Must operate Must release Max. voltage Power consumption Rated voltage (V) 50 Hz 60 Hz % of rated voltage Initial Rated AC 12 614 531 2.24 80 % max. 10 % min. 110 % ma...
https://www.ia.omron.com/products/family/965/specification.html
...rminals, except the alarm output terminals and power output terminals Dielectric strength 1,500 V, 50/60 Hz for 1 min between the power supply, control, output, and R and other terminals 1,50...
https://www.ia.omron.com/products/family/967/specification.html
... max. (when 24 VDC applied) Two G3PAs 14 mA max. (when 24 VDC applied) Must operate voltage 9.6 V ±10% Must release voltage 5 V min. Output voltage 12 VDC ±15% Characteristics Item S...
https://www.ia.omron.com/products/family/989/specification.html
...x. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 2 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) Insulation resistanc...
https://www.ia.omron.com/products/family/994/specification.html
...rating voltage Coil resistance Must operate voltage Must release voltage Power consumption DC 5 V 4 to 6 VDC 104 Ω 4 VDC max. 0.5 VDC min. Approx. 240 mW 12 V 9.6 to 14.4 VDC 600 Ω 9...
https://www.ia.omron.com/products/family/998/specification.html
... from the initials of the format name. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 Those with the initials E for Control Components is a product of less than 34. E...
https://www.ia.omron.com/products/index/control-components/E.html
... from the initials of the format name. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 Those with the initials H for Control Components is a product of less than 32. H...
https://www.ia.omron.com/products/index/control-components/H.html
... from the initials of the format name. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 Those with the initials K for Control Components is a product of less than 11. K...
https://www.ia.omron.com/products/index/control-components/K.html
...用1鍵1功能,輕鬆即可上手 使用高等級的超強功率,即使是低反射檢測體或大型檢測體也能安定檢出 (搭載GIGARAY)* *E3X-NA[][]V型系列除外。 更新日期 2015年8月8日 感測器 光纖感測器 光纖放大器 E3NX-CA ...
...XW2K-COM XW2R (PLC連接型) XW2R(泛用連接型) XW2D XW2B (伺服用中繼模組) XW2B (運動控制模組) XW2Z XW2Z-L XW2Z-[][][]P-V / S-V / S-CV / T Top of page...
...XW2K-COM XW2R (PLC連接型) XW2R(泛用連接型) XW2D XW2B (伺服用中繼模組) XW2B (運動控制模組) XW2Z XW2Z-L XW2Z-[][][]P-V / S-V / S-CV / T Top of page...
...XW2K-COM XW2R (PLC連接型) XW2R(泛用連接型) XW2D XW2B (伺服用中繼模組) XW2B (運動控制模組) XW2Z XW2Z-L XW2Z-[][][]P-V / S-V / S-CV / T Top of page...
...XW2K-COM XW2R (PLC連接型) XW2R(泛用連接型) XW2D XW2B (伺服用中繼模組) XW2B (運動控制模組) XW2Z XW2Z-L XW2Z-[][][]P-V / S-V / S-CV / T Top of page...
...Sensor Communications Unit Current consumption Normal mode: 80 mA max. (Power supply voltage 24 V) Eco ON: 70 mA max. (Power supply voltage 24 V) Eco LO: 75 mA max. (Power supply vol...
...t-in output Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Operation indicator (red) Opera...
...0.8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3 V max. (Load current 100 mA with cable length of 2 m) Indicator Operation indicator (red), Oper...
...mption 30 mA max. Control output NPN open collector 30 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...