Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 521 - 540695
PDF1 High-function General-purpose Inverters

...ication selection Max. applicable motor capacity [kW] Rated input current [A] Model Inductance [mH] Heat generation [W] Operating ambient temperature /humidity Location 200-V class 0.4 3G3RX2...

https://www.omron.com.tw/data_pdf/cat/rx2_i921-e1_2_8_csm1070916.pdf

PDFOMRON ROBOTICS AND SAFETY TECHNOLOGIES

...RIVATE LIMITED THE QUBE 5th Floor, Unit No. 501 - 504, M V Road, Marol, Andheri (EAST), Mumbai -MH-400059, India Tel: (91) 22-7128-8400/Fax: (91) 22-7128-8401 OMRON TAIWAN ELECTRONICS INC. 6F...

https://www.omron.com.tw/data_pdf/cat/tm_s_i892-e_2_1_csm1126729.pdf

PDFomRon 形D4NS-SK30 0686729-9B セーフティドアスイッチスライドキーユニット

...=a(Ibrnユ11f)ssll皿illj5tTadoS) 12~14Nm ・(㎞te幽asT㎞ Itmraarnbimtedefumbiamiento'])4NS-SK30-10℃a55℃丘mh泌 il・lasadeD4NS-SK3028㎏ap輌{iamente Giakv〔∬in白麹A9)messungen醐dt:〕㎜■Dhmensi(ns...

https://www.omron.com.tw/data_pdf/mnu/d4ns-sk30_inst-0686729-9b.pdf

PDFThank you for choosing this OMNUC FND-X-series pro...

...rs AC Reactor Model Rated current Inductance Loss Weight FND-X06L-j 3G3IV-PUZBAB5A2.1MH 5 A 2.1 mH 15 W 2.5 kg FND-X12L-j g FND-X06H-j 3G3IV-PUZBAB2.5A4.2MH 2.5 A 4.2 mH 15 W 2.5 kg ...

https://www.omron.com.tw/data_pdf/mnu/i524-04_fnd-x__x_-srt.pdf

PDFCat. No. I561-E1-08 USER’S MANUAL

...ive to be used. Specifications Reactor type Specifications Model Rated current (A) Inductance (mH) Weight (kg) Single-phase Reactors 3G3AX-DL2002 1.6 A 21.4 mH 0.8 kg 3G3AX-DL2004 3...

https://www.omron.com.tw/data_pdf/mnu/i561-e1-08_r88m-g_r7d-bp.pdf

PDFCat. No. I571-E1-08 USER’S MANUAL

...er phases Model Rated current Inductance Weight R88D-KTA5L Single-phase 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg R88D-KT01L 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg R88D-KT02L 3G3A...

https://www.omron.com.tw/data_pdf/mnu/i571-e1-08_r88m-k_r88d-kt.pdf

PDFCat. No. I572-E1-04 USER’S MANUAL

...ases Model Rated current Inductance Weight R88D-KNA5L-ML2 Single- phase 3G3AX-DL2002 1.6 A 21.4 mH Approx. 0.8 kg R88D-KN01L-ML2 3G3AX-DL2004 3.2 A 10.7 mH Approx. 1.0 kg R88D-KN02L-...

https://www.omron.com.tw/data_pdf/mnu/i572-e1-04_r88m-k__r88d-kn_-ml2.pdf

PDFInverter MX2/RX Series EtherCAT®Communication Unit

....001 [] Possible (TxPDO) 3015 hex 45 hex 151A hex Motor 1 Parameter L H022 RW 1 to 65530 0.01 [mH] Possible (TxPDO) 3015 hex 47 hex 151C hex Motor 1 Parameter Io H023 RW 1 to 65530 0.01 [A] ...

https://www.omron.com.tw/data_pdf/mnu/i574-e1-06_3g3ax-mx2-ect_rx-ect.pdf

PDFI596-E-08 Hornet 565 Robot User’s Guide

...ion Parameter Value ware only) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65)≤ Vdemag≤(+V - 45) DC short circuit current limit 0.7 A≤ILIM≤2.5 A Peak short circ...

https://www.omron.com.tw/data_pdf/mnu/i596-e-08_hornet565.pdf

PDFI614-E-01 Mobile Robot Software Suite

...el lights, LCDor touch screen). 3. Plug the joystick into the robot’s JOYSTICK connection port (MH-LDshown below): Figure3-11:Connecting the joystick to the robot CAUTION: Driving the robot w...

https://www.omron.com.tw/data_pdf/mnu/i614-e-01_mobile_robot_software_suite.pdf

PDFi4L Robots User's Manual i4-350L

...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 Belt Encoder Specifications Specifications for the XBELTIO connections are provided be...

https://www.omron.com.tw/data_pdf/mnu/i658-e-08_i4-350l_450l_550l.pdf

PDFi4L Robots with EtherCAT User's Manual

...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 Belt Encoder Specifications Specifications for the XBELTIO connections are provided be...

https://www.omron.com.tw/data_pdf/mnu/i659-e-02_i4-350l_450l_550l.pdf

PDFi4H Robots User's Manual i4-650H

...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 TIO Specifications Specifications for the TIO circuits are provided below. Type Item S...

https://www.omron.com.tw/data_pdf/mnu/i660-e-04_i4-650h_750h_850h.pdf

PDFi4H Robots with EtherCAT User's Manual

...t voltage at inductive load (turn OFF) (+V - 52)≤Vdemag≤(+V - 41) where Iout = 0.5 A and load≥1 mH 2-3-3 TIO Specifications Specifications for the TIO circuits are provided below. Type Item S...

https://www.omron.com.tw/data_pdf/mnu/i661-e-06_i4h.pdf

PDFInverter RX2 Series EtherCAT®Communication Unit

...t pos- sible 403B 81 3B0A Async. Motor constant L, 1st-motor Hb114 RW 1 to 1000000000 0.000001 (mH) Not pos- sible 403B 83 3B0C Async. Motor constant Io, 1st-motor Hb116 RW 1 to 1000000 0.01 ...

https://www.omron.com.tw/data_pdf/mnu/i663-e1-02_3g3ax-rx2-ect.pdf

PDFCK3A-series Direct PWM Amplifier

... 10 msec A8 fault Phase short to IPM OFF < 3µsec AC fault Current loop response time < 1 msec 1 mH 3-Ph brushless Motor Y-winding Dynamic brake relay response time ...

https://www.omron.com.tw/data_pdf/mnu/o050-e1-05_ck3a-g___l.pdf

PDFOPERATION MANUAL Cat. No. W418-E1-08

...High alarm) H (ITEM 014) HH (High/high alarm) HH (ITEM 013) DV (Deviation alarm) DVA (ITEM 042) MH (High MV limit) MHA (ITEM 078) ML (Low MV limit) MLA (ITEM 079) 31 Basic PID (Block Model 01...

https://www.omron.com.tw/data_pdf/mnu/w418-e1-08_cxone-al___-v4.pdf

PDFCK3A-series Direct PWM Amplifier

...c Notes A8 fault Phase short to IPM OFF < 3 µsec AC fault Current loop response time < 1 msec 1 mH 3-Ph brushless Motor Y-winding Dynamic brake relay response time ...

https://www.omron.com.vn/data_pdf/cat/ck3a_ds_e_2_1_csm1118896.pdf

PDFMulti-function Compact Inverter

...20.2 Normal load *1 2.2 22.0 Light load 3.0 24.0 Model 3G3AX-DL2002 Heat Inductance generation [mH] [W] Operating ambient temperature/ humidity Location 21.4 8 3G3AX-DL2004 10.7 3G3AX-DL2007 ...

https://www.omron.com.vn/data_pdf/cat/mx2-v2_ds_e_4_1_csm1126864.pdf

PDFAC Servomotors/ Servo Drives SMARTSTEP2

...ions Reactor type Single-phase Reactors Three-phase Reactor Model Rated current (A) Inductance (mH) Weight (kg) 3G3AX-DL2002 1.6 A 21.4 mH 0.8 kg 3G3AX-DL2004 3.2 A 10.7 mH ...

https://www.omron.com.vn/data_pdf/cat/r88m-g_r7d-bp_i813-e1_9_15_csm2685.pdf

結果 521 - 540695

国/地域選択

Related Contents