Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 541 - 560687
PDFeCobra 600 and 800 Robot with EtherCAT

...x.), 28 μsec typical (typical) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V 45) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short ...

https://www.omron.com.vn/data_pdf/mnu/i653-e-03_ecobra__00.pdf

PDFViper 650/850 Robot with EtherCAT

... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...

https://www.omron.com.vn/data_pdf/mnu/i654-e-02_viper_650_850.pdf

PDFiX3 Robot with EtherCAT User's Manual

... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...

https://www.omron.com.vn/data_pdf/mnu/i655-e-01_ix3.pdf

PDFiX4 650 H/HS and 800 H/HS Robot

... Output voltage at inductive (+V - 65) ≤ Vdemag ≤ (+V - 45) load turnoff (Iout = 0.5A, Load = 1 mH) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short circuit current Iovpk ≤ 4 A N...

https://www.omron.com.vn/data_pdf/mnu/i656-e-02_ix4.pdf

PDFi4L Robots User's Manual i4-350L

...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH Belt Encoder Specifications Specifications for the XBELTIO connections are provided below. I...

https://www.omron.com.vn/data_pdf/mnu/i658-e-08_i4-350l_450l_550l.pdf

PDFi4L Robots with EtherCAT User's Manual

...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH Belt Encoder Specifications Specifications for the XBELTIO connections are provided below. I...

https://www.omron.com.vn/data_pdf/mnu/i659-e-01_i4-350l_450l_550l.pdf

PDFi4H Robots User's Manual i4-650H

...age at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 0.5 A and load ≥ 1 mH TIO Specifications Specifications for the TIO circuits are provided below. Type Input circui...

https://www.omron.com.vn/data_pdf/mnu/i660-e-04_i4-650h_750h_850h.pdf

PDFi4H Robots with EtherCAT User's Manual

...e at inductive load (turn OFF) (+V - 52) ≤ Vdemag ≤ (+V - 41) where Iout = 2 0.5 A and load ≥ 1 mH TIO Specifications Specifications for the TIO circuits are provided below. Type Input circui...

https://www.omron.com.vn/data_pdf/mnu/i661-e-06_i4h.pdf

PDFInverter RX2 Series EtherCAT® Communication Unit

...Not possible 403B 81 3B0A Async. Motor constant L, 1st-motor Hb114 RW 1 to 1000000000 0.000001 (mH) Not possible 403B 83 3B0C Async. Motor constant Io, 1st-motor Hb116 RW 1 to 1000000 0.01 (A...

https://www.omron.com.vn/data_pdf/mnu/i663-e1-02_3g3ax-rx2-ect.pdf

PDFCat. No. W418-E1-08 SYSMAC CXONE-AL@@D-V4

... type LL (Low/low alarm) L (Low alarm) H (High alarm) HH (High/high alarm) DV (Deviation alarm) MH (High MV limit) ML (Low MV limit) Tag ITEM LL (ITEM 016) L (ITEM 015) H (ITEM 014) HH (ITEM ...

https://www.omron.com.vn/data_pdf/mnu/w418-e1-08_cxone-al___-v4.pdf

PDFCat. No. W428-E1-03 SYSMAC WS02-LCMC1-EV2

...ed AUTO or remote (CAS) Manual Manual Pointer No Manual Pointer Output limit (ML) Output limit (MH) Make Manual Pointer and MV open direction settings when registering the Control Screen. Ref...

https://www.omron.com.vn/data_pdf/mnu/w428-e1-03_ws02-lcmc1-ev2.pdf

PDFEQUO Series Portable Power Monitor

...teries (when using battery power supply) 2 Alkaline dry cells or nickel-metal hydride cells (Ni-MH) Important Manganese battery cells cannot be used. Use two batteries of the same type. Do no...

https://www.omron.com.vn/data_pdf/mnu/z410-e1-04_zn-ctx21_kmx21.pdf

PDF[-] R88M-UE, R88D-UE データシート

...0.3 0.6 0.4 0.3 巻線抵抗 Ω 6.99 1.34 1.23 0.45 1.22 0.706 0.435 巻線インダクタンス mH 13.2 7.2 7.9 5.7 2.0 4.0 2.3 電気的時定数 ms 1.9 5.4 6.4 13 1.6 5.7 5.3 質量 kg 約0.5 約1.1 約1.7 約3.4 ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/r88m-ue_r88d-ue.pdf

PDF[-] SYSDRIVEオプション(JE, JV, MV, RV, EVシリーズ用) データシート

...ンバータ 直流リアクトル 最大適用電圧クラス モータ容量 (kW) 定格電圧 定格電流 インダクタンス (V) (A) (mH) 形式形3G3HVPUZDAB□ ( ) 定格電圧 定格電流 インダクタンス (V) (A) (...

https://www.fa.omron.co.jp/data_pdf/closed/cat/saoo-211f-web1_sysdrive_option_je_jv_mv_rv_ev.pdf

PDF[I564-E1-01] 3G3AX-PG Encorder Feedback Board User...

...acity. × Ω H022 Motor parameter L 0.01 to 99.99 100.0 to 655.3 Depends on the motor capacity. × mH H023 Motor parameter Io 0.01 to 99.99 100.0 to 655.3 Depends on the motor capacity. × A H024...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i564-e1-01_3g3ax-pg.pdf

PDF[I653-E-03] eCobra 600 and 800 Robot with EtherCAT...

...x.), 28 μsec typical (typical) Output voltage at inductive load turnoff (Iout = 0.5 A, Load = 1 mH) (+V - 65) ≤ Vdemag ≤ (+V 45) DC short circuit current limit 0.7A ≤ ILIM ≤ 2.5 A Peak short ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i653-e-03_ecobra__00.pdf

PDF[SBCC-834L] CS1W-LCB01/LCB05, CS1D-CPU□□P, CJ1G-CP...

...切替ブロック(形式 168)は、基本 PID(形式 011)、高度 PID(形式 012)、 またはブレンド PID(形式 013)と組み合わせて使用します。 P、I、D、MH、ML、ローカル SP を各々最大 8 セット(バンク No.1...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbcc-834l_cs1w-lcb_cs1d-cpu_cs1g-cpu.pdf

PDF[SBCE-489B] eCobra 600/800 スカラロボット EtherCATタイプ ユーザ...

...間 60 µsec (最大)、28 µsec (定格) 出力電圧(誘導負荷ターンオ (+V - 65) ≤ Vdemag ≤ (+V フ)(Iout = 0.5 A、負荷 = - 45) 1 mH) DC短絡回路電流制限 0.7A ≤ ILIM ≤ 2.5 A ピーク短絡電流 Iovpk ≤ 4 A...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbce-489b_ecobra__00.pdf

PDF[SGFE-706A] K2MR マルチモータリレー 通信マニュアル

...0001 0000 ~ 0004 B-01 定格電流設定 80 64 C1 0000 電流センサ種別による SET-ML:0014 ~ 01F4 SET-MM:002D ~ 015E SET-MH:001F ~ 00B4 CT1A:0064 ~ 0640 CT5A:0064 ~ 0640 ※ 1 単位注意 2-2 B-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sgfe-706a_k2mr.pdf

PDF[W406-E1-10] CS1W-LCB0[], CS1D-CPU[][][]P, CJ1G-CP...

... (Block Model 013). Up to 8 sets (bank numbers 1 to 8) can be recorded for each of the P, I, D, MH, ML, and local SP values. The bank numbers can be switched and the recorded bank data can be...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w406-e1-10_cs1w-lcb_cs1d-cpu_cs1g-cpu.pdf

結果 541 - 560687

国/地域選択

Related Contents