Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 761 - 7801593
PDF[Z415-E1-08] MX-Z2000H-V1 series Fiber Laser Marke...

...the laser power ON/OFF based on the 15 Safety relay signal from the interlock connector. Model: G7SA-2A2B DC24 *1 Do not use the USB interface for anything other than specified. Fiber Laser M...

https://www.fa.omron.co.jp/data_pdf/mnu/z415-e1-08_mx-z2000h-v1.pdf

PDFCSM_DST1 Series_DS_C_6_1 1 400-820-4535 www.fa.omr...

....1mA以下输出类型源流输出(PNP对应) 额定输出电流0.7A以下/输出 ON残留电压1.2V以下漏电流0.1mA以下适用的继电器G7SA-2A2B、EN50205类别A 故障率P级* (参考值) DC5V,1mA 额定负载(电阻的)AC240V时2A...

https://www.fa.omron.com.cn/data_pdf/cat/DST1 Series_DS_C_6_1.pdf

PDFCSM_DST1 Series_DS_E_7_4 1 Safety I/O Terminals

... 0.7 A max./output ON residual voltage 1.2 V max. Leakage current 0.1 mA max. Applicable relays G7SA-2A2B, EN50205 Class A Failure rate P level * (Reference value) 5 VDC, 1 mA Rated load (res...

https://www.fa.omron.com.cn/data_pdf/cat/dst1_series_ds_e_7_4_csm1275.pdf

PDF1 F3SG-SR/PG F3SG-SR-K Common to

...switch S2: Lockout/interlock reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor Beam state: Unblocked Blocked Test switch (S1) Reset switc...

https://www.fa.omron.com.cn/data_pdf/cat/f3sg-sr_pg_f117-e1_1_8_csm1120108.pdf

PDF安全光幕/多光束安全传感器 F3SG-SR/PG 轻松掌握状态

...受光器投光器 KM1 KM2 S2 S1 KM1 KM2 S1:测试开关 S2:锁定/联锁复位按钮 KM1、KM2:带强制引导接点的安全继电器(G7SA)或电磁接触器 M:电机入光遮光测试按钮(S1) 复位按钮(S2) 控制输出 *3 智能连...

https://www.fa.omron.com.cn/data_pdf/cat/f3sg-sr_pg_sgfm-cn5-086_1_12.pdf

PDFEASY type simple and affordable hand protection

...e Emitter and Receiver. Test rod (Sold separately) Type Appearance Specifications Model Remarks G7SA Relays with Forcibly Guided Contacts •Nodes: 4 •Contact type: 2A2B •Rated switch load: 250...

https://www.fa.omron.com.cn/data_pdf/cat/f3sj_f074-e1_27_11_csm1816.pdf

PDF»安装工时减半,可降低引入成本的简易型 »适用于手指检测和特殊用途的高功能型

...度中相同的4个数字代替。 *2.同时使用投光器和受光器时,请订购两套F39-PB□□□□。 测试棒(另售) 种类形状规格型号备注 G7SA 安全继电器 •极数:4极 •接点构成:2A2B •额定开关负载: AC250V 6A、DC30V 6A ...

https://www.fa.omron.com.cn/data_pdf/cat/f3sj_schg-cn5-015_26_8.pdf

PDFᯧѢՓ⫼ ᔎࢆ 䭓䎱⾏Ẕ⌟ ৃ䴴 3ϾⳈ㾖ˈՓ⫼ㅔऩⱘᣛ⼎♃ ᅝܼܝᐩ

...m F39-JD3B 5m F39-JD5B 7m F39-JD7B 10m F39-JD10B 15m F39-JD15B 20m F39-JD20B 类型外观规格型号备注带强制导向接点的 G7SA继电器 •极数:4 •接点类型:2NO+2NC •额定负载: 6A时AC250V,6A时DC30V...

https://www.fa.omron.com.cn/data_pdf/cat/f3sr-b_ca_c_10_1.pdf

PDFEase of Use Robust Long Distance Detection

...-JD7B 10 m F39-JD10B 15 m F39-JD15B 20 m F39-JD20B Type Appearance Specifications Model Remarks G7SA Relays with Forcibly Guided Contacts •Number of poles: 4 •Contact type: 2NO+2NC •Rated loa...

https://www.fa.omron.com.cn/data_pdf/cat/f3sr-b_f089-e1_10_1_csm2138.pdf

PDFCSM_G7S-_-E_DS_E_7_3 1 Relays with Forcibly Guided...

... of enclosed construction. Therefore, do not wash the G7S with water or detergent. Mounting The G7SA can be installed in any direction. Indicates a potentially hazardous situation which, if n...

https://www.fa.omron.com.cn/data_pdf/cat/g7s-_-e_ds_e_7_3_csm1272.pdf

PDF1 Relays with Forcibly Guided Contacts G7SA

...1 Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards •Additional Push-In Plus terminal sockets are used to save wiring work in comparison with tradition...

https://www.fa.omron.com.cn/data_pdf/cat/g7sa_j120-e1_12_11_csm1269.pdf

PDF新产品信息 1 安全继电器 G7SA 符合EN标准的小型纤薄型安全继电器

...新产品信息 1 安全继电器 G7SA 符合EN标准的小型纤薄型安全继电器 •新增Push-In Plus端子台插座系列,与以往的螺钉端子相比,更节省配线工时 (与以往的螺钉端子相比,可缩短配线工时约60%*) •带强制导向...

https://www.fa.omron.com.cn/data_pdf/cat/g7sa_sgfr-cn5-207_12_8.pdf

PDFNX㌱ࡍᆿޞ᧝࡬ಞ CIP Safety㌱㔕 G9SP系列 安全控制器

...下启动输入。 最大可能达到PL/ 类别使用设备型号停机类别复位方法相当于PLd/3 安全激光扫描器OS32C 安全继电器G7SA 0手动 OS32C的设定 ·外部继电器监控功能有效 ·启动/重启联锁 DC24V(白色) DC0V(褐色) 待...

https://www.fa.omron.com.cn/data_pdf/cat/os32c_schg-cn5-030_14_7.pdf

PDF» Compliant with PLd/Category 3

...egory Model Stop category Reset PLd/3 equivalent Safety Laser Scanner OS32C Forced Guided Relay G7SA 0Manual OS32C Configuration - External Device Monitoring Enabled - Start/Restart Interlock...

https://www.fa.omron.com.cn/data_pdf/cat/os32c_z298-e1_14_6_csm2602.pdf

PDF发生瞬间低压和停电时,为控制柜内的 DC24V设备提供后备 S8BA

...继电器 K8DT 按钮开关 A22N-P/A30N-P/M22N-P 紧急停止开关 A22NE-P 为控制柜带来全新价值的产品群安全继电器插座 (G7SA用) P7SA-PU 温控器(数字调节仪) E5CC-B/E5EC-B 温控器(数字调节仪) E5CD-B/E5E...

https://www.fa.omron.com.cn/data_pdf/cat/s8ba_ppdc-cn5-002_1_2.pdf

PDF让控制柜更小巧 开关电源 S8VK-S •小巧的机身和紧贴安装,让设计更自由

...断电源(UPS) S8BA 测量和监测继电器 K8DT 按钮开关 A22N-P/A30N-P/M22N-P 紧急停止按钮开关 A22NE-P 安全继电器插座 (G7SA用) P7SA-PU 温控器 (数字调节仪) E5CC-B/E5EC-B 温控器 (数字调节仪) E5C...

https://www.fa.omron.com.cn/data_pdf/cat/s8vk-s_sgtc-cn5-063_1_8.pdf

PDF制御機器 直接開路動作機構を備え、IEC/EN 60947-5-1に適合した規

...力(PNP対応) 定格出力電流0.5A以下/点 ON残電圧1.2V以下各出力端子とV間漏れ電流0.1mA以下項目仕様使用リレーG7SA-2A2B,IEC61810-3 Class A 故障率P水準(参考値*) DC5V 1mA 定格負荷(抵抗負荷) AC240...

https://www.fa.omron.com.cn/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf

PDF本产品是用于机械安全的Component商品,不同的使用方法有时可能无法满足要求的安全性。请遵

...对应) 额定输出电流 0.5A以下/点 ON残电压1.2V以下各输入端子和V间漏电流 0.1mA以下项目规格使用继电器 G7SA-2A2B,EN50205 Class A 故障率P水准(参考值*) DC5V 1mA 额定负载(电阻负载) AC240V 2A DC30...

https://www.fa.omron.com.cn/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-2141729-1c.pdf

PDFSafety Light Curtain F3SG-4RA□□□□-25-01TS Series

...onnect to 0V if a switch is not required) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...

https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-4ra____-25-01tsseries(quickinstallationmanual)_inst-5132821-8d.pdf

PDFSafety Light Curtain F3SG-4RA□□□□-25-02TS

...ls when using these cables and connector. KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor +24 VDC (Brown) Not used (Yellow) *3 TEST (Black) *1 Not used (White) *3...

https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-4ra____-25-02ts(quickinstallationmanual)_inst-9309529-9e.pdf

結果 761 - 7801593

国/地域選択

Related Contents