IAグローバル検索 |
... or Override Switch S4, S5: Muting sensor KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor PLC: Programmable controller (Used for monitoring only. NO...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_raseries(quickinstallationmanual)_inst-7999687-9h.pdf
...e (used), Muting disabled and PNP Outputs KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor +24 VDC (Brown) Not used (Yellow) *5 TEST (Black) *2 Not used (White) *5...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sg-_rr_seies(quickinstallationmanual)_inst-9308038-0d.pdf
...tch is not required) : Interlock/lockout reset switch : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) K1 KM1 KM2 0 V Emitter Receive...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
...ストスイッチ S2:インターロック/ロックアウトリセットスイッチ KM1, KM2:強制ガイド接点付きセーフティリレー(形G7SA)やマグネットコンタクタ KM3:ソリッドステート・コンタクタ(形G3J) M:3相モータ ...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sn-b_scee-717.pdf
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power Zone Select 1 (Orange/White) W...
https://www.fa.omron.com.cn/data_pdf/mnu/os32c_inst-99863-0020l.pdf
...ストスイッチ S2:インターロック/ロックアウトリセットスイッチ KM1, KM2:強制ガイド接点付きセーフティリレー(形G7SA)やマグネットコンタクタ KM3:ソリッドステート・コンタクタ(形G3J) M:3相モータ ...
https://www.fa.omron.com.cn/data_pdf/mnu/scee-713_f3sn-a.pdf
...䕧ߎ1˄㓓㡆˅ ࠊ䕧ߎ2˄ⱑ㡆˅ 0V˄㪱㡆˅ ሣ㬑 -ࡼԡᓣ S1 :䚼⌟䆩ᓔ݇ S2 :Ѧ䫕/䫕ᅮԡᓔ݇ KM1, KM2 :ᏺᔎࠊᇐᴎᵘ⚍ⱘᅝܼ 㒻⬉఼(G7SA)⺕㾺఼ KM4 :ᗕ㾺఼(G3J) M :3Ⳍ偀䖒 E1 :24VDC⬉⑤(S82K) PLC :ৃ㓪ࠊ఼ ˄⫼ѢⲥˈϢᅝܼಲ䏃᮴݇˅ -...
https://www.fa.omron.com.cn/data_pdf/mnu/sche-c-710a_f3sj.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
... switch S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
...cuit to 24V if the switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...onnect to 24V if a switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...is not required) S2 Interlock reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor M :3-phase motor E1 :24VDC power supply (S82K) Unblocked Blocked Ex...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-727f-1_eng_f3sr-430b.pdf
...(connect to 0 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 1.0 m...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1 *1. Use a switch for small loads (input specifications: 24 V, 3 ...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) 24 V (Brown) External device m...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) Shield Not Used (Red) 0 V (Blu...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf