Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 801 - 8201593
PDFF3SJ-B P25-02TS Series Safety Light Curtain

... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) 24 V (Brown) External device m...

https://www.fa.omron.com.cn/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf

PDFḋᴀ㓪োSCHG-C-718B ᅝܼܝᐩ ᅝܼܝᐩF3SJ-AغغغغPغغ㋏߫(Ver.2)᪡԰᠟...

...ߎ1˄㓓㡆˅ ᅝܼ䕧ߎ2˄ⱑ㡆˅ 0V˄㪱㡆˅ ሣ㬑 -᠟ࡼ໡ԡ῵ᓣ S1 :໪䚼⌟䆩ᓔ݇ S2 :㘨䫕/䫕ᅮ໡ԡᓔ݇ KM1, KM2 :ᏺᔎࠊᇐ৥ᴎᵘ᥹⚍ⱘᅝܼ 㒻⬉఼(G7SA)៪⺕᥹㾺఼ KM3 :䋳䕑៪PLC˄⫼Ѣⲥ᥻˅ KM4 :೎ᗕ䖲᥹఼(G3J) M :3Ⳍ偀䖒 E1 :24VDC⬉⑤(S82K) PLC :ৃ㓪⿟᥻ࠊ...

https://www.fa.omron.com.cn/data_pdf/mnu/schg-c-718b_f3sj.pdf

PDF安全光幕F3SG-□SR□系列 手册编号SGFM-CN5-726A

...(黄) 辅助输出(红) 控制输出1 (黑) 控制输出2 (白) KM1 KM2 M S1:锁定复位开关 KM1、KM2:带强制导向接点安全继电器(G7SA)或电磁接触器 M:电机 *4 *1.设定NPN时请反转电源极性进行接线。 *2.检测距离使用...

https://www.fa.omron.com.cn/data_pdf/mnu/sgfm-cn5-726a_f3sg-_sr_.pdf

PDFUser's Manual Safety Laser Scanner

...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power Functional Earth (Green) 24VDC...

https://www.fa.omron.com.cn/data_pdf/mnu/z296-e1-15_os32c.pdf

PDFF3SG-□RA/□RE Series Safety Light Curtain

...㻺㻣㻻㻺㻠㻻㻺 Unblocked Blocked Beam state OSSD KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor OSSD1: Black OSSD2: White +24 VDC: Brown Not used: ...

https://www.fa.omron.com.cn/data_pdf/mnu/z352-e1-11_f3sg-_r_.pdf

PDFF3SG-4RA□□□□-25-01TS Series Safety Light Curtain

...e to 0 V if this switch is not required.) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...

https://www.fa.omron.com.cn/data_pdf/mnu/z380-e1-04_f3sg-4ra____-25-01ts.pdf

PDFF3SG-□RR Series Safety Light Curtain

...etting) Unblocked Blocked Beam state OSSD KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: Motor +24 VDC (Brown) Not used (Yellow) *4 TEST (Black) *2 Not used (White) *4 Not use...

https://www.fa.omron.com.cn/data_pdf/mnu/z383-e1-04_f3sg-_rr.pdf

PDFF3SG-4RA□□□□-25-02TS Series Safety Light Curtain

...etting) Unblocked Blocked Beam state OSSD KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: Motor +24 VDC (Brown) Not used (Yellow) *3 TEST (Black) *1 Not used (White) *3 Not use...

https://www.fa.omron.com.cn/data_pdf/mnu/z391-e1-03_f3sg-4ar____-25-02ts.pdf

PDFSafety Light Curtain F3SG-□SR□Series

...KM2 S1 KM1 KM2 M S1: Lockout reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor Receiver Emitter OSSD 1 (Black) OSSD 2 (White) 24V/0V (Bro...

https://www.fa.omron.com.cn/data_pdf/mnu/z405-e1-07_f3sg-sr_pg.pdf

PDFSafety I/O Terminals DST1 Series CSM_DST1 Series_D...

...11 VDC min. OFF voltage 5 VDC max. OFF current Input current (DST1-MRD08SL-1) Applicable relays G7SA-2A2B, EN50205 Class A 1 mA max. Failure rate P level * (Reference value) 5 VDC, 1 mA 6 mA ...

https://www.omron-ap.co.in/data_pdf/cat/dst1_series_ds_e_7_4_csm1275.pdf

PDFSafety Light Curtain/Safety Multi-Light Beam

...switch S2: Lockout/interlock reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor *1. Reverse the polarity of the power supply when using in...

https://www.omron-ap.co.in/data_pdf/cat/f3sg-sr_pg_f117-e1_1_8_csm1120108.pdf

PDFSafety Light Curtain F3SJ Series

...utput F3SJ-E Accessories (Sold separately) Relays with Forcibly Guided Contacts Type Appearance G7SA Relays with Forcibly Guided Contacts G7S-@-E Relays with Forcibly Guided Contacts Specific...

https://www.omron-ap.co.in/data_pdf/cat/f3sj_f074-e1_27_11_csm1816.pdf

PDFRelays with Forcibly Guided Contacts

... of enclosed construction. Therefore, do not wash the G7S with water or detergent. Mounting The G7SA can be installed in any direction. 5 Terms and Conditions Agreement Read and understand th...

https://www.omron-ap.co.in/data_pdf/cat/g7s-_-e_ds_e_7_3_csm1272.pdf

PDFRelays with Forcibly Guided Contacts

...Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards • Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditiona...

https://www.omron-ap.co.in/data_pdf/cat/g7sa_j120-e1_12_11_csm1269.pdf

PDFSafety Laser Scanner OS32C Compliant with PLd/Cate...

.../3 equivalent Model Stop category Reset 0 Manual Safety Laser Scanner OS32C Forced Guided Relay G7SA Note: The above PL is only the evaluation result of the example. The PL must be evaluated ...

https://www.omron-ap.co.in/data_pdf/cat/os32c_z298-e1_14_6_csm2602.pdf

PDF安全上の要点 DST1-MRD08SL-1 2.各部の名称と外形寸法 DC-DCコンバータ

...注意ください。 項目出力タイプ定格出力電流 ON残電圧 ● 安全出力部仕様 (リレー出力) 項目仕様使用リレー G7SA-2A2B,IEC61810-3 Class A 故障率 P水準(参考値 * ) DC5V 1mA 定格負荷(抵抗負荷) AC24...

https://www.omron-ap.co.in/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf

PDFSafety Light Curtain F3SG-4RA□□□□-25-01TS Series h...

...onnect to 0V if a switch is not required) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...

https://www.omron-ap.co.in/data_pdf/mnu/f3sg-4ra____-25-01tsseries(quickinstallationmanual)_inst-5132821-8d.pdf

PDFSafety Light Curtain F3SG-4RA□□□□-25-02TS http://w...

...M1 KM2 +24 VDC Power Supply KM2 0 VDC KM1 KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor KM2 M *1. Connect the line to 24 V via a test switch (N.O. contact) if E...

https://www.omron-ap.co.in/data_pdf/mnu/f3sg-4ra____-25-02ts(quickinstallationmanual)_inst-9309529-9e.pdf

PDFSafety Light Curtain F3SJ-B□□□□□25 Series

...equired) S2 : Interlock/lockout reset switch KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1 Use a switch for micro l...

https://www.omron-ap.co.in/data_pdf/mnu/f3sj-b_____25_-e_____25series(quickinstallationmanual)_inst-3126345-4b.pdf

PDFSafety Light Curtain F3SJ-B□□□□N25-01T Series

... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1 Use a switch for micro load...

https://www.omron-ap.co.in/data_pdf/mnu/f3sj-b____n25-01tseries(quickinstallationmanual)_inst-3125963-5b.pdf

結果 801 - 8201593

国/地域選択

Related Contents