| IAグローバル検索 |
...re proper heat dissipation to increase the long-term reliability of the S8M. 3. Install the S8M so that the air flow circulates around it, because the S8M is designed to radiate heat by means...
https://www.fa.omron.co.jp/data_pdf/cat/s8m_t232-e1_3_4_csm2006.pdf
...02 Power Supply To Be Connected The power consumption of the S8T-DCBU-02 is approximately 10 W, so make sure that the output capacity of the connected Power Supply is sufficient. If the S8T-D...
https://www.fa.omron.co.jp/data_pdf/cat/s8t-dcbu-02_t234-e1_10_3_csm138.pdf
...mA max. Note: 1. Alarm signal output is not equipped with an internal current limiting circuit, so be sure that the current flowing to the alarm signal output terminals does not exceed 50 mA....
https://www.fa.omron.co.jp/data_pdf/cat/s8v-cp_t226-e1_5_1_csm1074611.pdf
...oducts with safety outputs of which voltage, current, and power are limited to a certain level, so that not to cause an electric shock or fire,” and is evaluated by UL1310. For the UL Class 2...
https://www.fa.omron.co.jp/data_pdf/cat/s8v-cp_t227-e1_2_1_csm1074606.pdf
...rotection (B) Face-up mounting Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in ...
https://www.fa.omron.co.jp/data_pdf/cat/s8vk-g_t056-e1_7_1_csm1012199.pdf
...d by installing it properly and sufficiently considering heat dissipation. • Install the S8VK-R so that the air flow circulates around it, because the S8VK-R is designed to radiate heat by me...
https://www.fa.omron.co.jp/data_pdf/cat/s8vk-r_t059-e1_4_8_csm1013796.pdf
...ning. If the input is connected to a UPS, do not connect a UPS with a square-wave output. Doing so will cause the internal temperature of the product to increase, possibly causing smoking or ...
https://www.fa.omron.co.jp/data_pdf/cat/s8vk-s_t205-e1_2_1_csm1050136.pdf
...ning. If the input is connected to a UPS, do not connect a UPS with a square-wave output. Doing so will cause the internal temperature of the product to increase, possibly causing smoking or ...
https://www.fa.omron.co.jp/data_pdf/cat/s8vk-t_t061-e1_11_1_csm1021435.pdf
...ning. If the input is connected to a UPS, do not connect a UPS with a square-wave output. Doing so will cause the internal temperature of the product to increase, possibly causing smoking or ...
https://www.fa.omron.co.jp/data_pdf/cat/s8vk-x_t210-e1_2_2_csm1060688.pdf
... Protection Output voltage (V) Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in ...
https://www.fa.omron.co.jp/data_pdf/cat/s8vs_t026-e1_8_1_csm2022.pdf
...ay occur. Motor M Note: To prevent the buzzer sounding when power is turned ON, install a timer so that the buzzer sounds only when the timer’s contacts are closed. 5 SAO Operation Settings ...
https://www.fa.omron.co.jp/data_pdf/cat/sao_ds_e_5_4_csm390.pdf
...ed. The calculation method is as follows: The PICK UP index scale value is between 1.0 and 3.0, so calculate the voltage multiplying factor for both 1.0 and 3.0. 15 V (Operating value)/1 (PIC...
https://www.fa.omron.co.jp/data_pdf/cat/sdv_ds_e_6_6_csm392.pdf
...M_SensingBand_CN_E_1_2 !WARNING Do not touch the terminals while power is being supplied. Doing so may possibly result in electric shock. Do not attempt to disassemble, repair, or modify the ...
https://www.fa.omron.co.jp/data_pdf/cat/sensingband_cn_e_1_2_csm524.pdf
...more efficient heat dissipation. The OMRON SENTECH camera has a special heat dissipation design so that it can operate stably even with natural cooling using the heat dissipation of the indiv...
https://www.fa.omron.co.jp/data_pdf/cat/stc-lbs_poe-swir_q347-e1-01.pdf
..._Compare2 Converts from the line measurement data to the 2D shape data. Correction is performed so that the target data has the same slope, height and position as the master 2D shape data. Me...
https://www.fa.omron.co.jp/data_pdf/cat/sysmac-xr014_p113-e1_2_4_csm1056203.pdf
...onfocal Fiber Type Displacement Sensor of ZW-8000/7000/5000 series. Z930 NX-SL@@@@ NX-SI@@@@ NX-SO@@@@ NX-series Safety Control Unit User's Manual Learning how to use the NXseries Safety Cont...
https://www.fa.omron.co.jp/data_pdf/cat/sysmac-xr____p102-e1_8_8_csm1047496.pdf
...いとき。 ZW-8000/7000/5000シリーズのセンサコントローラの設定方法について説明します。 SGFM-710 形NX-SL□□□□ 形NX-SI□□□□ 形NX-SO□□□□ NXシリーズ セーフティコントロールユニット ユーザーズマニュア...
https://www.fa.omron.co.jp/data_pdf/cat/sysmac-xr____sbcz-049_8_9.pdf
... allow you to group and nest the names of functions, function block definitions, and data types so that you can manage them. This reduces the chance of duplicated names and makes the entities...
https://www.fa.omron.co.jp/data_pdf/cat/sysmac_studio_ds_e_18_36_csm1000603.pdf
...いて知りたいとき NXユニットのハードウェアや設定方法、機能について説明します。 形NX-SL□□□□ SGFM-710 形NX-SI□□□□ 形NX-SO□□□□ NXシリーズセーフティコントロールユニットユーザーズマニュアル NXシリ...
https://www.fa.omron.co.jp/data_pdf/cat/sysmac_studio_ds_j_18_39.pdf
... tool changer to attach on the tool side. (All OnRobot grippers have this component integrated, so this is only necessary when user is developing their own tool.) Quick OnRobot Changer Kit 4....
https://www.fa.omron.co.jp/data_pdf/cat/tm_hw3_2_plug_and_play_m100-e_1_1_csm1127672.pdf