PDFMachine Automation Controller NX Series

...I' 'G' 'G' 'E' 'R' (Normal processing: measurement data 369 171 -1,LOT123456 DATE05/2012,123456<CR>) Receive Message 33 36 39 20 31 37 31 20 2D 31 2C 4C ‘3’‘6’‘9’‘’‘1’‘7’‘1’‘’‘-’‘1’‘,’‘L’...

https://www.fa.omron.com.cn/data_pdf/mnu/z443-e-01_f430-f.pdf

PDFVision Sensor F440-F/430-F/F420-F Series

...a communication between the IO controller and IO devi- ces at determined cycles. Set by IO data CR. Acyclic Parameter Data / Device Identification Used for parameter settings, IO device confi...

https://www.fa.omron.com.cn/data_pdf/mnu/z444-e-05_f4_0-f.pdf

PDFVision Sensor FH Series Vision System

...) -20: Error (other errors) Count C No. of models detected If none detected, 0 Mean correlation CR Mean correlation Surface correlation CRN Surface correlation Contour correlation CRG Contour...

https://www.fa.omron.com.cn/data_pdf/mnu/z445-e1-03_fh-505__smda-gs050b.pdf

PDFVision Sensor FH Series Vision System

...re shown in right. Output : Serial (Ethernet) Delimiter string:\20 (Space) Terminate string:\r (CR) 3 Open the“Output data”tab to confirm the settings are as figure shown in right. SY.RBVAR_R...

https://www.fa.omron.com.cn/data_pdf/mnu/z446-e1-06_fh.pdf

PDFZ452-E-05 (84-9000440-02 Rev E)

...communications.

Read strings
PDFZ453-CN5-01 V440-F C卡口读码器 通信手册

...令 < 3C 20 > 3E 字符表示十六进制表示读取结果 1 31 2 32 3 33 读取周期中 4 34 5 35 CR...

https://www.fa.omron.com.cn/data_pdf/mnu/z453-cn5-01.pdf

PDFV440-F C-Mount Code Reader Communication Manual

...imal value as a parameter, add lowercase h immediately after the K command. For example, to set CR (hexadecimal value: 0D) to the footer (postamble), you can enter it as follows. 3 Controllin...

https://www.fa.omron.com.cn/data_pdf/mnu/z453-e-03_v440-f.pdf

PDF1 STC-FDR-SW01 Factory Drive Recorder

...nd external input, following command is send to this application. Command Description trigger n(CR) n:Camera No.(1~8) “0" is a recording from all cameras (CR): Carriage return code...

https://www.fa.omron.com.cn/data_pdf/mnu/z457-e1-02_stc-fdr-sw01.pdf

PDFZ461-E-04 (84-9000460-02-D) User Manual

...rd Character Usage: Example: With Wild Card Character defined as the default asterisk, defining CR*34 as the master symbol will result in matches for CR134 and CR234, but not CR2345. Entering...

https://www.fa.omron.com.cn/data_pdf/mnu/z461-e-04 (84-9000460-02)_v460-h.pdf

PDFV460-H Industrial Handheld DPM Reader

...imal value as a parameter, add lowercase h immediately after the K command. For example, to set CR (hexadecimal value: 0D) to the footer (postamble), you can enter it as follows. ...

https://www.fa.omron.com.cn/data_pdf/mnu/z462-e1-01_v460-h.pdf

PDFZ465-E1-01 Machine Automation Controller NX-series

...one (default) Baud rate 115,200 bps 115,200 bps (default) Header --- None (default) Footer --- <CR...

https://www.fa.omron.com.cn/data_pdf/mnu/z465-e1-01_v320-f_v420-f_v430-f.pdf

PDFUser Manual Z476-E-03 (84-9000470-02-C)

...t with an ! followed by the command name. All commands must be fol- lowed by a carriage return (CR). Example: !TRIGGER<CR...

https://www.fa.omron.com.cn/data_pdf/mnu/z476-e-03_vhv5-f.pdf

PDFAutofocus Multicode Reader VHV5-F Series

...tring: 12345, Format Output: Space, Preamble: None, Postamble: \r\n Transmit: S Response: 12345<CR> 3 Controlling Operation and Data Output with Ethernet 3-15 Autofocus Multicode Reader V...

https://www.fa.omron.com.cn/data_pdf/mnu/z477-e-01_vhv5-f.pdf

PDFZ481-E1-01 Machine Automation Controller NJ-series

... the right varies depending on your environment. Response Format 1 2 3 4 5 6 7 8 9 0 A 02 C D E CR LF Read data Footer 8. Initializing the System 24 8. Initializing the System This document a...

https://www.fa.omron.com.cn/data_pdf/mnu/z481-e1-01_v460-h.pdf

PDFZ483-E1-01 Machine Automation Controller NX-series

... the right varies depending on your environment. Response Format 1 2 3 4 5 6 7 8 9 0 A 02 C D E CR LF Footer Read data 8. Initializing the System 26 8. Initializing the System This document a...

https://www.fa.omron.com.cn/data_pdf/mnu/z483-e1-01_v460-h.pdf

PDFZP-series EtherNet/IP™ Communication Unit

... and actuators, and outputs control signals based on a pro- gram. It manages the entire system. CR + LF --- CR (Carriage Return) and LF (Line Feed) are control characters that in- di...

https://www.fa.omron.com.cn/data_pdf/mnu/z496-e1-02_zp-eip.pdf

PDFCIDRW SYSTEM V640 SERIES AMPLIFIER UNITS ETHERNET ...

...A-3. A test is preformed for the Amplifier Unit using the data 12345678. Command code Test data CR Data 1 Data 2 Data 3 Data 4 1 0 1 2 3 4 5 6 7 8 0Dh If the response test data matches the co...

https://www.fa.omron.com.cn/data_pdf/mnu/z497-e1-02.pdf

PDFCIDRW SYSTEM V640 SERIES AMPLIFIER UNITS ETHERNET ...

...A-3. A test is preformed for the Amplifier Unit using the data 12345678. Command code Test data CR Data 1 Data 2 Data 3 Data 4 1 0 1 2 3 4 5 6 7 8 0Dh If the response test data matches the co...

https://www.fa.omron.com.cn/data_pdf/mnu/z497-e1-02_v640-ham11(-l)-etn-v.pdf

PDFZP-series RS-232C Communication Unit

... and actuators, and outputs control signals based on a pro- gram. It manages the entire system. CR + LF --- CR (Carriage Return) and LF (Line Feed) are control characters that in- di...

https://www.fa.omron.com.cn/data_pdf/mnu/z499-e1-01_zp-rsa.pdf

PDFHOST CONNECTION MANUAL Cat. No. Z924-E1-02

...r RS-485. Regular/RS232C Transmission control procedure Choose format 1/format 4. Form1(without CR,LF) Time out judge time Set the time-out period. 30(300msec) 2 - 2 RS-232C Serial Communicat...

https://www.fa.omron.com.cn/data_pdf/mnu/z924-e1-02_g9sp.pdf