Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 81 - 100681
PDFCat. No. W348-E1-08 DRT1-COM GT1 Series

...ON: ON current of the Transistor Input Unit ION can be determined as follows: ION = (VCC – VR – VF) / RIN VF: The Transistor Input Unit’s internal residual voltage (1.5 V with a MULT...

https://www.omron.co.id/data_pdf/mnu/w348-e1-08_drt1-com_gt1.pdf

PDFCat. No. W348-E1-08 DRT1-COM GT1 Series

...ON: ON current of the Transistor Input Unit ION can be determined as follows: ION = (VCC – VR – VF) / RIN VF: The Transistor Input Unit’s internal residual voltage (1.5 V with a MULT...

https://www.omron.com.au/data_pdf/mnu/w348-e1-08_drt1-com_gt1.pdf

PDFOPERATION MANUAL Cat. No. W348-E1-08

...t) ION: ON current of the Transistor Input Unit ION can be determined as follows: ION = (VCC–VR–VF) / RIN VF: The Transistor Input Unit’s internal residual voltage (1.5 V with a MULT...

https://www.omron.com.tw/data_pdf/mnu/w348-e1-08_drt1-com_gt1.pdf

PDFCat. No. W348-E1-08 DRT1-COM GT1 Series

...ON: ON current of the Transistor Input Unit ION can be determined as follows: ION = (VCC – VR – VF) / RIN VF: The Transistor Input Unit’s internal residual voltage (1.5 V with a MULT...

https://www.omron.com.vn/data_pdf/mnu/w348-e1-08_drt1-com_gt1.pdf

K3FM 超小型プラグインタイプ信号変換器/形式/種類 | オムロン制御機器

...新 : 2024/10/01 横幅を最大化 分類 商品名称 形式 アイソレータ 直流入力変換器 形K3FM-VS 直流入力変換器(超高速) 形K3FM-VF 電源なしアイソレータ(1CH) 形K3FM-SN1 電源なしアイソレータ(2CH) 形K...

https://www.fa.omron.co.jp/products/family/1722/lineup.html

S8VK-T スイッチング・パワーサプライ(120/240/480/960Wタイプ)/ご使用の前に ...

...用可能です。 ・ダイオードの種類、耐圧、電流の目安は次の通りです。 ・製品の出力電圧は、ダイオードD1、D2の順方向電圧(VF)の降下分だけ高く設定してください。また、ダイオードは製品の出力電流(lOU...

https://www.fa.omron.co.jp/products/family/3369/preuse.html

S8JX-P 开关电源(300/600W型)/注意事项 | OMRON Industrial Aut...

...份操作。(需要安装二极管) 电源A、B,请使用相同型号的电源。 • 电源A、B的输出电压,设定时请高出二极管D1、D2正向电压(VF)的下降量。 此外,二极管会导致电源输出电流(IOUT) ×二极管正向电压...

https://www.fa.omron.com.cn/products/family/1989/preuse.html

S8VK-T 开关电源 (120/240/480/960W型)/注意事项 | OMRON Indus...

...下信息作为二极管类型、耐电压以及电流的参考。 • 请增大电源A、B的输出电压设定,使增加量等于二极管D1、D2正向电压(VF)的下降量。  此外,二极管会导致等量于电源输出电流(IOUT)×二极管正向电压(...

https://www.fa.omron.com.cn/products/family/3369/preuse.html

S8VK-WA 开关电源(240/480/960/2000W型)/注意事项 | OMRON Indu...

...,请勿进行并联运行。 • 二极管的种类、耐电压、电流的大致标准如下。 • 设定S8VK-W的输出电压时,请高出二极管D1、D2正向电压(VF)的下降量。此外,二极管会导致产品输出电流(IOUT)×二极管正向...

https://www.fa.omron.com.cn/products/family/3753/preuse.html

S8VK-WB 开关电源 (240/480/960W型)/注意事项 | OMRON Industri...

...,请勿进行并联运行。 • 二极管的种类、耐电压、电流的大致标准如下。 • 设定S8VK-W的输出电压时,请高出二极管D1、D2正向电压(VF)的下降量。此外,二极管会导致产品输出电流(IOUT)×二极管正向...

https://www.fa.omron.com.cn/products/family/3821/preuse.html

S8VS 开关电源(15/30/60/90/120/180/240/480W)/注意事项 | OMR...

...额定输出电压以上  • 正向电流(IF):电源额定输出电流的2倍以上 • 电源A、B 的输出电压,设定时请高出二极管D1、D2 正向电压(VF)的下降量。 此外,二极管会导致电源输出电流(IOUT) × 二极管正向电压...

https://www.fa.omron.com.cn/products/family/807/preuse.html

PDF[SBCC-838C] PLC計装エンジニアリングガイド

...170 凡例 Q: 体積流量(Nm3/h) A: すきま断面積 Af:フロート 断面積 α: 流量係数 ρ: 流体密度 ρf:フロート 密度 Vf:フロート 体積 温度圧力補正(面積式流量計) 171 恒温槽の平均温度制御(入出力にバイアスが...

https://www.fa.omron.co.jp/data_pdf/mnu/sbcc-838c_cs.pdf

PDF[W468-E1-01] PLC-based Process Control Engineering...

... flow rate of the variable area flowmeter is represented by the following formula: Q=A*α [2/p]*[Vf(ρf -ρ)/Af] In this formula, α, Vf, Af, and Pf are constants: “A” represents flow ra...

https://www.fa.omron.co.jp/data_pdf/mnu/w468-e1-01_plc-based_process.pdf

PDFCat. No. W468-E1-01 PLC-based Process Control Engi...

...e flow rate of the variable area flowmeter is represented by the following formula: Q=A*α[2/p]*[Vf(ρf -ρ)/Af] In this formula,α, Vf, Af, and Pf are constants:“A”represents flow rate ...

https://www.fa.omron.com.cn/data_pdf/mnu/w468-e1-01_plc-based_process.pdf

G5NB パワーリレー/ご使用の前に | オムロン制御機器

...確認を必ず実施してください。 駆動回路例 当社検証条件 ・印加電圧:定格電圧 ・Duty:50%以上 ・周波数:10kHz以上 ・ダイオードVf:0.4 V以下 情報更新 : 2021/04/01 ページ先頭へ戻る...

https://www.fa.omron.co.jp/products/family/2818/preuse.html

G5Q パワーリレー/ご使用の前に | オムロン制御機器

...確認を必ず実施してください。 駆動回路例 当社検証条件 ・印加電圧:定格電圧 ・Duty:50%以上 ・周波数:10kHz以上 ・ダイオードVf:0.4 V以下 ラッチングリレーの基本動作について ・セットコイルの入力...

https://www.fa.omron.co.jp/products/family/3925/preuse.html

PDFMOS FETリレー G3VMシリーズ 生産終了のお知らせ

...力 IO 側 連続負荷電流 入出力間耐電圧 電気的性能 記号 単位 最小 標準 最大 最小 標準 最大 VF V 1 1.15 1.3 1.1 1.27 1.4 IFT mA - 1.6 3 0.6 - 3 復帰LED順電流 IFC mA 0.1 - - 0.1 - - 最大出力オン...

https://www.fa.omron.co.jp/data_pdf/closed/2023005c_on.pdf

PDFAutomation Software Sysmac Studio

...ters Motor related parameters Status related parameters Motor Settings related parameters Motor Vf Curve related parameters Motor Autotuning related parameters Dc Braking related parameters P...

https://www.fa.omron.co.jp/data_pdf/mnu/i589-e1-13_sysmac-se2___.pdf

PDFオートメーションソフトウェア Sysmac Studio ドライブ機能 オペレーションマニュアル

...タス ステータス関連パラメータを表示します。 モータ設定 モータ設定関連パラメータを表示します。 モータ Vf 曲線 モータ Vf 曲線関連パラメータを表示します。 モータオートチューニング モー...

https://www.fa.omron.co.jp/data_pdf/mnu/sbce-401n_sysmac-se2___.pdf

生産終了品一覧 - 生産終了品/推奨代替品 | オムロン制御機器

...リーズ V8 VC-DL100 VC-HR VC-IAL-TDO VC-QG VC1000 VC3000 V2 / 3500 V2 VC4500 / PC VC7700 VCM VCR800 VF VICC VL VOC-3S VT-PRO-Sシリーズ VT-RNS シリーズ VT-RNS-ptH VT-RNS-ptS VT-RNSII VT-RNSII p...

https://www.fa.omron.co.jp/product/closed/allitem

結果 81 - 100681

国/地域選択

Related Contents