...safety requirement only when combined with PLd-compliant equipment. EDM (feedback) input 3G3MX2 KM1 Safety output Safety Unit * Certified under the applicable safety standards IEC61508, ISO13...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/i570-e1-02_mx2_series.pdf
...97 98 X1 X2 GRD IC H1 H3H2 H4 IC T1 T2 T3 L3 L2 L1 1 5 3 2 6 4 L3 L2 L1 T1 T2 T3 -M -KM1 -KM2 -E1 A1 (+) 1 A2 (-) 97 98 -KM1 -KM2 -SA -KM1 -KM1 -KM2 -KM2 12 3 切断...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/j156-cn5-01_g3Ja-d.pdf
...97 98 X1 X2 GRD IC H1 H3H2 H4 IC T1 T2 T3 L3 L2 L1 1 5 3 2 6 4 L3 L2 L1 T1 T2 T3 -M -KM1 -KM2 -E1 A1 (+) 1 A2 (-) 97 98 -KM1 -KM2 -SA -KM1 -KM1 -KM2 -KM2 12 3 切断...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/j156-cn5-01_g3ja-c.pdf
...it on the host computer or other means. Communication Reference p.6-7 Main module (N, E module) KM1 KM2 M 24V DC 24V DC Relay output module (R, R1, R2 module) K1 K2 Fuse KM1,KM2 : Ma...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/schg-705h-web1_eng_f3sx.pdf
... (2) Emergency stop switch 80 Recommended Enabling Circuits Appendix D Circuit Diagram A22K A4E KM1 M KM1 KM2 Ry Manual reset D4NS KM2 Advantages •Reset mode can be selected individu...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/v090-e1-11_nsh5-sq_10b-v2.pdf
...14 S24 T21 T22 S44 T31 S54 T32 X1 T33 X2 T41 G9SX-NSA222-T03-@ Control circuit L1 AND OFF Y1 NC KM1 KM2 S3 Feedback Loop NC NC 24 VDC PLC etc. T42 +24 V A2 T12 Guard S2 Non-contact Door Switc...
https://www.omron.com.tw/data_pdf/closed/cat/d40z_c145-e1_8_4_csm2647.pdf
...停止類別復歸方法相當於PLe/4 非接觸式門開關D40Z型非接觸式門開關控制器G9SX-NSA222-T03-@型(DC24V) 1手動操作 - DC24V - - KM1 KM2 11 21 22 12 DC24V GND S3 KM1 -NC KM2 -NC 白黑 S2 G9S...
https://www.omron.com.tw/data_pdf/closed/cat/d40z_sgfm-054_tw_7_9.pdf
...d) S2: Override Cancel Switch S3: Lockout Reset Switch or Override Switch S4, S5: Muting sensor KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor S1 S...
https://www.omron.com.tw/data_pdf/closed/cat/f3sg-r_f094-e1_12_7_csm1040037.pdf
...器外部繼電器監控有效手動復歸 PNP(原廠設定) 投光器外部測試:24V動作(原廠設定) 2ON2ON 3ON3ON 4ON4ON 7ON7ON 4ON S2 S1 KM1 KM2 KM1 KM2 ɮ24V 0V KM1 KM2 M ѓ௦ӵ S1ȈขၑᜱȞसϛሰ्ᜱ...
https://www.omron.com.tw/data_pdf/closed/cat/f3sg-r_sgfm-069_tw_6_7.pdf
...You cannot connect only Function Slaves together. KE1 Unit Combination Table Note: Refer to the KM1 Product Catalog (Cat. No. N170) for details on the KM1. Model Number Structure Mod...
https://www.omron.com.tw/data_pdf/closed/cat/ke1_n173-e1_6_3_csm1004014.pdf
...,加上1台通訊子機,共可增設5台子機。 只有複數台功能子機的連結將無法完成系統配置。 KE1元件組合一覽表註.關於KM1型的詳細說明請參閱KM1型單機型錄(KANC-005)。 型號構成型號基準 A基本型號 ...
https://www.omron.com.tw/data_pdf/closed/cat/ke1_sgte-626_tw_6_2.pdf
...KM1 智慧電量監控器多迴路型 NEW 能源的源的此環保標籤代表產品符合本公司獨家訂定之環保基準。 可掌握可診斷的可視化全新發現的省電一次滿足各種電量量測需求 KWKWKW在電力不足問題日趨嚴重的情形下,僅靠...
https://www.omron.com.tw/data_pdf/closed/cat/km1_kanc-006_tw_8_4.pdf
...KM1 N E W Your Energy Usage Multi-circuit Smart Power Monitor Visualize, Monitor, and Analyze Authorized Distributor: In the interest of product improvement, specifications are subject to cha...
https://www.omron.com.tw/data_pdf/closed/cat/km1_n170-e1_8_2_csm1004013.pdf
...ng (DIP Switch 1: OFF) •Auxiliary output without delay mode (DIP Switch 2: ON) S1: Reset switch KM1, KM2: Magnetic contactor M: Motor KM1 KM2 L1 L2 L3 M KM1 KM2 S1 SGE Blue ...
https://www.omron.com.tw/data_pdf/closed/cat/sge_scc_f088-e1_9_3_csm2126.pdf
...op category Reset PLd/3 equivalent Safety Mat UMA series Mat Controller MC3 0 Manual 24 VDC MC3 KM1 KM2 M UMA UMA Blue White Black Brown Blue White Black Brown Power supply Control Circuit 13...
https://www.omron.com.tw/data_pdf/closed/cat/uma_a250-e1_2_2_csm1057753.pdf
...類別使用機器型號停止類別復歸方法相當於PLd/3 安全踏墊UMA系列安全踏墊控制器MC3型 0使用手冊 DC24V MC3 KM1 KM2 M UMA UMA ᙣҪ ༄ ᙣҪ ༄ Power supply Control Circuit 13 23 14 KM1 KM2 24 Y...
https://www.omron.com.tw/data_pdf/closed/cat/uma_sgfm-073_tw_2_3.pdf
...External Test: 0 V Inactive S1: External test switch(connect to 0V if a switch is not required) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC pow...
...g Connector (F39-CN5). Keep the F3SG-R from cutting oils when using these cables and connector. KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor +24 VDC (Brown) No...
...E B: Pink MUTE A: Gray RESET: Yellow *2 F39-JGA-L F39-JGA-D S1 Power Supply +24 VDC 0 VDC KM2 KM1 S4 S5 S2 S3 *3 IN PLC *4 S1: Test Switch (Connect the line to 0 V if this switch is not req...
...sabled, Manual Reset Mode, External Test in 24 V Active (used), Muting disabled and PNP Outputs KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor +24 VDC (Brown) No...