Page top

Primary Contents

General-purpose Relays

Model Number of Poles Operating Coil Ratings Contact Ratings File No.
MY( )
("New" model)
2 6 to 240V AC
5 to 125V DC
10A 30V DC
10A 250V AC
LR31928
(CSA C22.2(No.14))
4 5A 250V AC(Same polarity)
5A 30V DC(Same polarity)
MY( )
(excluding "New" model)
2 6 to 240V AC
6 to 125V DC
5A 28V DC(Resistive)
5A 240V AC(General Use)
LR31928
(CSA C22.2(No.0, No.14))
3
4 5A 240V AC(General Use)(Same polarity)
5A 28V DC(Resistive)(Same polarity)
LY( ) 1 6 to 240V AC
6 to 125V DC
15A 30V DC(Resistive)
10A 240V AC(General Use)
TV-5 120V AC TV rating
1/2HP 120V AC power rating
2 15A 120V AC(Resistive)
15A 30V AC(Resistive)
10A 240V AC(General Use)
1/2HP 120V AC power rating
TV-3 120V AC TV rating
3 10A 30V DC(Resistive)
10A 240V AC(General Use)
1/2HP 120V AC power rating
4
MK 2
3
6 to 260V AC
6 to 130V DC
Ag contacts
5A 230V AC(Resistive)
5A 28V DC(Resistive)
LR35535
(CSA C22.2(No.0, No.14))
AgCdO contacts
10A 230V AC(Resistive)
10A 28V DC(Resistive)
MK-I/-S 2
3
6 to 240V AC
6 to 110V DC
10A 250V AC(Resistive)
10A 28V DC(Resistive)
7A 250V AC(General Use)
G7J-( )-P(Z)
G7J-( )-B(Z)
G7J-( )-T(Z)
4PST-NO
3PST-NO/SPST-NC
DPST-NO/DPST-NC
24 to 240V AC
6 to 110V DC
NO contact(Single Contact)
25A 277V AC(General Use)
25A 30V DC(Resistive)
LR35535
(CSA C22.2(No.14, No.950))
NC contact(Single Contact)
8A 277V AC(General Use)
NO contact(Twin Contacts)
1A 277V AC(General Use)
NC contact(Twin Contacts)
1A 277V AC(General Use)
G7T-1122S SPST-NO 12 to 125V DC
24 to 240V DC
5A 30V DC(General Use)
1A 250V AC(General Use)
LR35535
(CSA C22.2(No.14))
G7T-1112S SPST-NO 10A 250V AC(General Use)
10A 30V DC(Resistive)
1/2HP 240V AC

Contactors

Model Number of Poles Operating Coil Ratings Contact Ratings File No.
J7AN-E3
J7AN-E9
J7ARN-E9
12, 24V DC 1/8HP 110 to 120V AC(1ph)
3HP 200 to 240V AC(3ph)
5HP 440 to 480V AC(3ph)
5HP 550 to 600V AC(3ph)
10A 120V AC(General Use)
15A 240V AC(Resistive)
LR35535
(CSA C22.2.(No.14))

Solid-state Relays

Model Output Ratings File No.
G3PA-210B-VD 10A 240V AC LR35535
(CSA C22.2(No.14, No.950))
G3PA-220B-VD 20A 240V AC
G3PA-240B-VD 40A 240V AC
G3PA-260B-VD 60A 240V AC
G3PA-420B-VD 20A 400V AC
G3PA-430B-VD 30A 400V AC
G32A-A10-VD 10A 240V AC
G32A-A20-VD 20A 240V AC
G32A-A40-VD 40A 240V AC
G32A-A60-VD 60A 240V AC
G3PA-420B-VD(-2) 20A 400V AC LR35535
(CSA C22.2(No.14))
G3PA-430B-VD(-2) 30A 400V AC
G32A-A420-VD(-2) 20A 400V AC
G32A-A430-VD 30A 400V AC
G3PA-420B-VD-2 20A 480V AC
G3PA-430B-VD-2 30A 480V AC
G3PA-450B-VD-2 50A 480V AC
G32A-A420-VD-2 20A 480V AC
G32A-A430-VD-2 30A 480V AC
G32A-A450-VD-2 50A 480V AC
G3NE-205T(L)(-2)-US 5A 240V AC
G3NE-210T(L)(-2)-US 10A 240V AC
G3NE-220T(L)(-2)-US 20A 240V AC
G9H-205S-US 5A 250V AC
G9H-210S-US 10A 250V AC
G3CN-202P(L)(1)-US 2A 264V AC
G3CN-203P(L)(1)-US 3A 264V AC
G3CN-DX02P(1)-US 2A 52.8V DC
G3CN-DX03P(1)-US 3A 52.8V DC
G3MB-102PL(-UTU) 2A 120V AC LR35535
(CSA C22.2(No.14, No.950))
G3MB-202P(L)(-UTU) 2A 240V AC
G3DZ-2R6PL 0.6A 240V AC
0.6A 125V DC
LR35535
(CSA C22.2(No.14))
G3M-202P(L)-US(-4)
G3M-202P(L)-UTU(-1)(-4)
2A 250V AC LR35535
(CSA C22.2(No.14, No.950))
G3M-102PL-US(-4)
G3M-102P(L)-UTU(-4)
2A 125V AC
G3M-203P(L)(-4)
G3M-203P(L)-UTU-1(-4)
3A 250V AC
G3M-205P(L)-VD-1(-4) 5A 250V AC
G3S-201P(L)- (PD)-US 1A 250V AC LR35535
(CSA C22.2(No.14))
G3SD-Z01P-(PD)-US 1A 24V DC
G3TA-IAZR02S-US 25mA 32V DC
G3TA-IDZR02S(M)-US 25mA 32V DC
G3TA-OA202SZ-US 2A 250V AC
G3TA-OA202SL-US 2A 250V AC
G3TA-ODX02S-US 2A 60V DC
G3TB-IAZR02P-US 25mA 24V DC
G3TB-IDZR02P-US 25mA 24V DC
G3TB-OA203PZ(M)-US 3A 240V AC
G3TB-OA203PL-US 3A 240V AC
G3TB-ODX03P(M)-US 3A 48V DC
G3TB-OD201P-US 1.5A 200V DC
G3NA-205B(-UTU) 5A 240V AC LR35535
(CSA C22.2(No.14, No.950))
G3NA-210B(-UTU) 10A 240V AC
G3NA-220B(-UTU) 20A 240V AC
G3NA-240B(-UTU) 40A 240V AC
G3NA-410B 10A 480V AC
G3NA-420B 20A 480V AC
G3NA-440B 40A 480V AC
G3NA-D210B(-UTU) 10A 200V DC
G3NA-275B-UTU 75A 240V AC
G3NA-290B-UTU 90A 240V AC
G3NA-475B-UTU 75A 480V AC
G3NA-490B-UTU 90A 480V AC
G3R-IAZR1SN-UTU 100mA 32V DC LR35535
(CSA C22.2(No.0, No.14))
G3R-IDZR1SN-UTU 100mA 32V DC
G3R-IDZR1SN-1-UTU 100mA 32V DC
G3R-OA202SZN-UTU 2A 264V AC
G3R-OA202SLN-UTU 2A 264V AC
G3R-ODX02SN-UTU 2A 60V DC
G3R-OD201SN-UTU 1.5A 200V DC
G3R-102P(L)N-US 2A 125V AC
G3R-202P(L)N-US 2A 250V AC
G3RD-101PN-US 1.5A 125V DC
G3RD-X02PN-US 2A 50V DC
G3B-205S-VD 5A 250V AC LR35535
(CSA C22.2(No.14))
G3BD-103S-VD 3A 125V DC
G3H-203S(L)(N)-VD 3A 240V AC LR35535
(CSA C22.2(No.14))
G3HD-X03S(N)-VD 3A 48V DC
G3F-202SN-VD 3A 240V AC LR35535
(CSA C22.2(No.14))
G3F-203S(L)(N)-VD 3A 48V DC
G3FD-X03S(N)-VD 3A 48V DC
G3FD-102S(N)-VD 2A 110V DC
G3J-T205BL(-C) 0.75kW(4.8A) 240V AC LR35535
(CSA C22.2(No.14))
G3J-T211BL(-C) 2.2kW(11.1A) 240V AC
G3J-T217BL(-C) 3.7kW(17.4A) 240V AC
G3J-T403BL 0.75kW(2.4A) 400V AC
G3J-T405BL 2.2kW(5.5A) 400V AC
G3J-S205BL 0.75kW(4.8A) 240V AC
G3J-S211BL 2.2kW(11.1A) 240V AC
G3J-S403BL 0.75kW(2.4A) 400V AC
G3J-S405BL 2.2kW(5.5A) 400V AC
G3J-205BL(-2) 0.75kW(4.8A) 240V AC
G3J-211BL(-2) 2.2kW(11.1A) 240V AC
G3PE-215B(L) 15A 240V AC LR35535
(CSA C22.2(No.14))
G3PE-225B(L) 25A 240V AC
G3PE-235B(L) 35A 240V AC
G3PE-245B(L) 45A 240V AC
G3PE-515B(L) 15A 480V AC
G3PE-525B(L) 25A 480V AC
G3PE-535B(L) 35A 480V AC
G3PE-545B(L) 45A 480V AC
G3PE-215B-3(N)(H) 15A 240V AC
G3PE-215B-2(N)(H)
G3PE-225B-3(N)(H) 25A 240V AC
G3PE-225B-2(N)(H)
G3PE-235B-3(N)(H) 35A 240V AC
G3PE-235B-2(N)(H)
G3PE-245B-3(N)(H) 45A 240V AC
G3PE-245B-2(N)(H)
G3PE-515B-3(N)(H) 15A 480V AC
G3PE-515B-2(N)(H)
G3PE-525B-3(N)(H) 25A 480V AC
G3PE-525B-2(N)(H)
G3PE-535B-3(N)(H) 35A 480V AC
G3PE-535B-2(N)(H)
G3PE-545B-3(N)(H) 45A 480V AC
G3PE-545B-2(N)(H)
G3PC-220B-VD 20A 240V AC LR35535
(CSA C22.2(No.14))
G3PX-220EUN 20A 200V AC LR35535
(CSA C22.2(No.14))
G3PX-240EUN 40A 200V AC
G3PX-260EUN 60A 200V AC
G3PX-220EH(N) 20A 200V AC
G3PX-240EH(N) 40A 200V AC
G3PX-260EH(N) 60A 200V AC
G3PX-220EC 20A 200V AC
G3PX-240EC 40A 200V AC
G3PX-260EC 60A 200V AC
G32A-EA-US 15mA 12V DC LR35535
(CSA C22.2(No.14))
G3MC-101P(L)(-VD) 1A 120V AC LR35535
(CSA C22.2(No.14, No.950))
G3MC-201P(L)(-VD)(-1) 1A 240V AC
G3MC-202P(L)(-VD)(-1) 2A 240V AC
Note 1. Applicable standard numbers are given in parentheses in the File No. column.
Note 2. CSA certification for the G3JA was obtained from C-UL-US (CSA 22.2 No.14).
Model Input Ratings File No.
G3ZA-4H203-FLK-UTU AC100 to 240V 1514593
(CSA C22.2 No.0-M91, No.14)
G3ZA-4H403-FLK-UTU AC400 to 480V
G3ZA-8A203-FLK-UTU AC100 to 240V
G3ZA-8A403-FLK-UTU AC400 to 480V