Model | Number of Poles | Operating Coil Ratings | Contact Ratings | File No. |
---|---|---|---|---|
MY( ) ("New" model) |
2 | 6 to 240V AC 5 to 125V DC |
10A 30V DC 10A 250V AC |
LR31928 (CSA C22.2(No.14)) |
4 | 5A 250V AC(Same polarity) 5A 30V DC(Same polarity) |
MY( ) (excluding "New" model) |
2 | 6 to 240V AC 6 to 125V DC |
5A 28V DC(Resistive) 5A 240V AC(General Use) |
LR31928 (CSA C22.2(No.0, No.14)) |
3 | 4 | 5A 240V AC(General Use)(Same polarity) 5A 28V DC(Resistive)(Same polarity) |
LY( ) | 1 | 6 to 240V AC 6 to 125V DC |
15A 30V DC(Resistive) 10A 240V AC(General Use) TV-5 120V AC TV rating 1/2HP 120V AC power rating |
2 | 15A 120V AC(Resistive) 15A 30V AC(Resistive) 10A 240V AC(General Use) 1/2HP 120V AC power rating TV-3 120V AC TV rating |
3 | 10A 30V DC(Resistive) 10A 240V AC(General Use) 1/2HP 120V AC power rating |
4 | MK | 2 3 |
6 to 260V AC 6 to 130V DC |
Ag contacts 5A 230V AC(Resistive) 5A 28V DC(Resistive) |
LR35535 (CSA C22.2(No.0, No.14)) |
AgCdO contacts 10A 230V AC(Resistive) 10A 28V DC(Resistive) |
MK-I/-S | 2 3 |
6 to 240V AC 6 to 110V DC |
10A 250V AC(Resistive) 10A 28V DC(Resistive) 7A 250V AC(General Use) |
G7J-( )-P(Z) G7J-( )-B(Z) G7J-( )-T(Z) |
4PST-NO 3PST-NO/SPST-NC DPST-NO/DPST-NC |
24 to 240V AC 6 to 110V DC |
NO contact(Single Contact) 25A 277V AC(General Use) 25A 30V DC(Resistive) |
LR35535 (CSA C22.2(No.14, No.950)) |
NC contact(Single Contact) 8A 277V AC(General Use) |
NO contact(Twin Contacts) 1A 277V AC(General Use) |
NC contact(Twin Contacts) 1A 277V AC(General Use) |
G7T-1122S | SPST-NO | 12 to 125V DC 24 to 240V DC |
5A 30V DC(General Use) 1A 250V AC(General Use) |
LR35535 (CSA C22.2(No.14)) |
G7T-1112S | SPST-NO | 10A 250V AC(General Use) 10A 30V DC(Resistive) 1/2HP 240V AC |
Model | Number of Poles | Operating Coil Ratings | Contact Ratings | File No. |
---|---|---|---|---|
J7AN-E3 J7AN-E9 J7ARN-E9 |
― | 12, 24V DC | 1/8HP 110 to 120V AC(1ph) 3HP 200 to 240V AC(3ph) 5HP 440 to 480V AC(3ph) 5HP 550 to 600V AC(3ph) 10A 120V AC(General Use) 15A 240V AC(Resistive) |
LR35535 (CSA C22.2.(No.14)) |
Model | Output Ratings | File No. |
---|---|---|
G3PA-210B-VD | 10A 240V AC | LR35535 (CSA C22.2(No.14, No.950)) |
G3PA-220B-VD | 20A 240V AC | G3PA-240B-VD | 40A 240V AC | G3PA-260B-VD | 60A 240V AC | G3PA-420B-VD | 20A 400V AC | G3PA-430B-VD | 30A 400V AC | G32A-A10-VD | 10A 240V AC | G32A-A20-VD | 20A 240V AC | G32A-A40-VD | 40A 240V AC | G32A-A60-VD | 60A 240V AC | G3PA-420B-VD(-2) | 20A 400V AC | LR35535 (CSA C22.2(No.14)) |
G3PA-430B-VD(-2) | 30A 400V AC | G32A-A420-VD(-2) | 20A 400V AC | G32A-A430-VD | 30A 400V AC | G3PA-420B-VD-2 | 20A 480V AC | G3PA-430B-VD-2 | 30A 480V AC | G3PA-450B-VD-2 | 50A 480V AC | G32A-A420-VD-2 | 20A 480V AC | G32A-A430-VD-2 | 30A 480V AC | G32A-A450-VD-2 | 50A 480V AC | G3NE-205T(L)(-2)-US | 5A 240V AC | G3NE-210T(L)(-2)-US | 10A 240V AC | G3NE-220T(L)(-2)-US | 20A 240V AC | G9H-205S-US | 5A 250V AC | G9H-210S-US | 10A 250V AC | G3CN-202P(L)(1)-US | 2A 264V AC | G3CN-203P(L)(1)-US | 3A 264V AC | G3CN-DX02P(1)-US | 2A 52.8V DC | G3CN-DX03P(1)-US | 3A 52.8V DC | G3MB-102PL(-UTU) | 2A 120V AC | LR35535 (CSA C22.2(No.14, No.950)) |
G3MB-202P(L)(-UTU) | 2A 240V AC | G3DZ-2R6PL | 0.6A 240V AC 0.6A 125V DC |
LR35535 (CSA C22.2(No.14)) |
G3M-202P(L)-US(-4) G3M-202P(L)-UTU(-1)(-4) |
2A 250V AC | LR35535 (CSA C22.2(No.14, No.950)) |
G3M-102PL-US(-4) G3M-102P(L)-UTU(-4) |
2A 125V AC | G3M-203P(L)(-4) G3M-203P(L)-UTU-1(-4) |
3A 250V AC | G3M-205P(L)-VD-1(-4) | 5A 250V AC | G3S-201P(L)- (PD)-US | 1A 250V AC | LR35535 (CSA C22.2(No.14)) |
G3SD-Z01P-(PD)-US | 1A 24V DC | G3TA-IAZR02S-US | 25mA 32V DC | G3TA-IDZR02S(M)-US | 25mA 32V DC | G3TA-OA202SZ-US | 2A 250V AC | G3TA-OA202SL-US | 2A 250V AC | G3TA-ODX02S-US | 2A 60V DC | G3TB-IAZR02P-US | 25mA 24V DC | G3TB-IDZR02P-US | 25mA 24V DC | G3TB-OA203PZ(M)-US | 3A 240V AC | G3TB-OA203PL-US | 3A 240V AC | G3TB-ODX03P(M)-US | 3A 48V DC | G3TB-OD201P-US | 1.5A 200V DC | G3NA-205B(-UTU) | 5A 240V AC | LR35535 (CSA C22.2(No.14, No.950)) |
G3NA-210B(-UTU) | 10A 240V AC | G3NA-220B(-UTU) | 20A 240V AC | G3NA-240B(-UTU) | 40A 240V AC | G3NA-410B | 10A 480V AC | G3NA-420B | 20A 480V AC | G3NA-440B | 40A 480V AC | G3NA-D210B(-UTU) | 10A 200V DC | G3NA-275B-UTU | 75A 240V AC | G3NA-290B-UTU | 90A 240V AC | G3NA-475B-UTU | 75A 480V AC | G3NA-490B-UTU | 90A 480V AC | G3R-IAZR1SN-UTU | 100mA 32V DC | LR35535 (CSA C22.2(No.0, No.14)) |
G3R-IDZR1SN-UTU | 100mA 32V DC | G3R-IDZR1SN-1-UTU | 100mA 32V DC | G3R-OA202SZN-UTU | 2A 264V AC | G3R-OA202SLN-UTU | 2A 264V AC | G3R-ODX02SN-UTU | 2A 60V DC | G3R-OD201SN-UTU | 1.5A 200V DC | G3R-102P(L)N-US | 2A 125V AC | G3R-202P(L)N-US | 2A 250V AC | G3RD-101PN-US | 1.5A 125V DC | G3RD-X02PN-US | 2A 50V DC | G3B-205S-VD | 5A 250V AC | LR35535 (CSA C22.2(No.14)) |
G3BD-103S-VD | 3A 125V DC | G3H-203S(L)(N)-VD | 3A 240V AC | LR35535 (CSA C22.2(No.14)) |
G3HD-X03S(N)-VD | 3A 48V DC | G3F-202SN-VD | 3A 240V AC | LR35535 (CSA C22.2(No.14)) |
G3F-203S(L)(N)-VD | 3A 48V DC | G3FD-X03S(N)-VD | 3A 48V DC | G3FD-102S(N)-VD | 2A 110V DC | G3J-T205BL(-C) | 0.75kW(4.8A) 240V AC | LR35535 (CSA C22.2(No.14)) |
G3J-T211BL(-C) | 2.2kW(11.1A) 240V AC | G3J-T217BL(-C) | 3.7kW(17.4A) 240V AC | G3J-T403BL | 0.75kW(2.4A) 400V AC | G3J-T405BL | 2.2kW(5.5A) 400V AC | G3J-S205BL | 0.75kW(4.8A) 240V AC | G3J-S211BL | 2.2kW(11.1A) 240V AC | G3J-S403BL | 0.75kW(2.4A) 400V AC | G3J-S405BL | 2.2kW(5.5A) 400V AC | G3J-205BL(-2) | 0.75kW(4.8A) 240V AC | G3J-211BL(-2) | 2.2kW(11.1A) 240V AC | G3PE-215B(L) | 15A 240V AC | LR35535 (CSA C22.2(No.14)) |
G3PE-225B(L) | 25A 240V AC | G3PE-235B(L) | 35A 240V AC | G3PE-245B(L) | 45A 240V AC | G3PE-515B(L) | 15A 480V AC | G3PE-525B(L) | 25A 480V AC | G3PE-535B(L) | 35A 480V AC | G3PE-545B(L) | 45A 480V AC | G3PE-215B-3(N)(H) | 15A 240V AC | G3PE-215B-2(N)(H) | G3PE-225B-3(N)(H) | 25A 240V AC | G3PE-225B-2(N)(H) | G3PE-235B-3(N)(H) | 35A 240V AC | G3PE-235B-2(N)(H) | G3PE-245B-3(N)(H) | 45A 240V AC | G3PE-245B-2(N)(H) | G3PE-515B-3(N)(H) | 15A 480V AC | G3PE-515B-2(N)(H) | G3PE-525B-3(N)(H) | 25A 480V AC | G3PE-525B-2(N)(H) | G3PE-535B-3(N)(H) | 35A 480V AC | G3PE-535B-2(N)(H) | G3PE-545B-3(N)(H) | 45A 480V AC | G3PE-545B-2(N)(H) | G3PC-220B-VD | 20A 240V AC | LR35535 (CSA C22.2(No.14)) |
G3PX-220EUN | 20A 200V AC | LR35535 (CSA C22.2(No.14)) |
G3PX-240EUN | 40A 200V AC | G3PX-260EUN | 60A 200V AC | G3PX-220EH(N) | 20A 200V AC | G3PX-240EH(N) | 40A 200V AC | G3PX-260EH(N) | 60A 200V AC | G3PX-220EC | 20A 200V AC | G3PX-240EC | 40A 200V AC | G3PX-260EC | 60A 200V AC | G32A-EA-US | 15mA 12V DC | LR35535 (CSA C22.2(No.14)) |
G3MC-101P(L)(-VD) | 1A 120V AC | LR35535 (CSA C22.2(No.14, No.950)) |
G3MC-201P(L)(-VD)(-1) | 1A 240V AC | G3MC-202P(L)(-VD)(-1) | 2A 240V AC |
Note 1. Applicable standard numbers are given in parentheses in the File No. column. |
||||||||||||||
Note 2. CSA certification for the G3JA was obtained from C-UL-US (CSA 22.2 No.14). |
||||||||||||||
|
||||||||||||||