Page top

Primary Contents

Level Switches

Model Ratings File No.
61F-GN 100/200, 110/220, 120/240V AC LR95291
61F-G1N
61F-G2N
61F-G3N
61F-G4N
61F-IN
61F-GPN-V50 24, 100, 110, 120, 200, 220, 230, 240V AC
61F-GP-N8 100, 110, 120, 200, 220, 240V AC
K7L-AT50(D) 12 to 24V DC

Basic Switches

Model Ratings Standard No. File No.
Z-01H 0.1A 30V DC(Resistive)
0.1A 125V AC(General Use)
CSA C22.2
No.55
LR21642
Z-10F 0.6A 125V, 0.3A 250V DC(Resistive)
6A 125V, 6A 480V AC(General Use)
1/10HP 125V, 1/6HP 250V AC(power rating)
Parallel Circuit Connection
Z-10G 0.5A, 125V DC, 0.25A 250V DC(Resistive)
10A 250V AC(General Use)
Z-15 0.5A 125V, 0.25A 250V DC(Resistive)
15A 125V, 15A 250V, 15A 480V AC(General Use)
1/8HP 125V, 1/4HP 250V AC(power rating)
A-20G 0.5A 125V, 0.25A 250V DC(Resistive)
20A 125V, 20A 250V, 20A 480V AC(General Use)
1HP 125V, 2HP 250V AC(power rating)
10A 125V AC(Lamp load)
X-10G 10A 125V, 3A 250V DC(Resistive)
DZ-10G 0.5A 125V, 0.25A 250V DC(Resistive)
10A 125V, 10A 250V, 2A 480V AC(General Use)
1/8HP 125V, 1/4HP 250V AC(power rating)
Note 1: Certification is obtained with representative models. Ask your OMRON representative for details on the standards.
Note 2. The model with a rating of 100,000 operations is different from the standard model. Specify the desired model when ordering.
Note 3. The applicable standard number is given in the Standard No. column. The certification report number is given in the File No. column.

Limit Switches

Model Ratings Standard No. File No.
WL A600(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
480V AC: Make: 15A, Break: 1.5A
600V AC: Make: 12A, Break: 1.2A
Max. VA: Make: 7,200VA, Break: 720VA
CSA C22.2
No.14
LR45746
WL-LE A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
Max. VA: Make: 7,200VA, Break: 720VA
WL-LD 10A 115V AC, 0.8A 115V DC
WL01 0.1A 125V AC, 0.1A 30V DC
WL01-LE 0.1A 125V AC
WL01-LD 0.1A 115V AC, 0.1A 30V DC
D4A-01
(SPDT, double-break, without indicator)
A600(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
480V AC: Make: 15A, Break: 1.2A
600V AC: Make: 12A, Break: 1.2A
Max. VA: Make: 7,200VA, Break: 720VA
D4A-03
(SPDT, double-break, with neon lamp)
A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
Max. VA: Make: 7,200VA, Break: 720VA
D4A-05
(DPDT, double-break, simultaneous operation)
D4A-07
(DPDT, double-break, sequential operation)
D4A-09
(DPDT, double-break, center neutral operation)
B600(Carry current: 5A):
120V AC: Make: 30A, Break: 3.0A
240V AC: Make: 15A, Break: 1.5A
480V AC: Make: 7.5A, Break: 0.75A
600V AC: Make: 6.0A, Break: 0.60A
Max. VA: Make: 3,600VA, Break: 360VA
D4C
(without indicator)
B300(Carry current: 5A):
120V AC: Make: 30A, Break: 3.0A
240V AC: Make: 15A, Break: 1.5A
Max. VA: Make: 3,600V A, Break: 360V A
D4C
(with indicator)
5A 125V AC (General Use)
3A 250V AC (General Use)
3A 30V AC (Resistive)
D4CC-1, -2 D150(Carry current: 1A):
120V AC: Make: 3.6A, Break: 0.6A
Max. VA: Make: 432VA, Break: 72VA
D4CC-3, -4 1A 30V DC
SHL-[]55 A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
Max. VA: Make: 7,200VA, Break: 720VA
E76675
(C-UL listing based on Canadian safety standards)
D4MC
ZC
A300(Carry current: 10A):1/2A 125V
1/4A 250V DC Resistive
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
Max. VA: Make: 7,200VA, Break: 720VA
CSA C22.2
No.14
LR45258
ZC-01
D4MC-C
0.1A, 125V AC(resistive load)
0.1A, 30V DC
ZE/ZV/ZV2 1/2A, 125V, 1/4A 125V DC
15A 125V, 15A 250V, 15A 480V AC
1/8HP 125V, 1/4HP 250V AC
CSA C22.2
No.14
LR45746
D4E-N A300(Carry current: 10A)
Note: Certification is sometimes obtained with representative models. Ask your OMRON representative for details on the standards.
The certification report number is given for the applicable standard number and file number used for certification.