PDFCSM_CJ1W-PDC_PH41U_AD04U_DS_E_4_5
...le (−270 to 1,372°C) Measured temperature: 500°C −270°C:−6.458 mV 1,372°C: 54.86 mV Full scale: 61.344 Electromotive conversion of temperature coefficient: 61.344 mV×±0.01%/°C =±6.13...

https://www.ia.omron.com/data_pdf/cat/cj1w-pts_pdc_ph41u_ad04u_ds_e_4_5_csm1632.pdf

PDFCSM_CJ2M-CPU3__-CPU1_-MD21__DS_E_12_7
...ith wires sized between 28 and 24 AWG (0.2 to 0.08 mm2). Use a wire with an outer diameter of 1.61 mm max. Compatible Terminal Blocks Name OMRON model number Socket XG4M-4030 Stain Relief XG4...

https://www.ia.omron.com/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf

PDFCSM_common_sockets_DS_E_6_10 1 Common Sockets
...-E *1 Approx. 46 g PT08 Approx. 11 g PT08QN Approx. 10.4 g PT08-0 *2 Approx. 8 g PTF11A Approx. 61 g PT11 Approx. 13 g PT11QN PT11-0 *2 Approx. 12.2 g PTF14A Approx. 77 g PTFZ-14-E *1 Approx....

https://www.ia.omron.com/data_pdf/cat/common_sockets_ds_e_6_10_csm1819.pdf

PDFCompoNet Catalog
...e immunity Conforms to IEC 61000-4-4 2 kV (applied to power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z d...

https://www.ia.omron.com/data_pdf/cat/crt1_crt1b_componet_p056-e1_17_10_csm2176.pdf

PDFCompoNet Catalog
...e immunity Conforms to IEC 61000-4-4 2 kV (applied to power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z d...

https://www.ia.omron.com/data_pdf/cat/crt1_crt1b_componet_p056-e1_17_22.pdf

PDFProgrammable Controller CS1D Duplex System
...0BASE-TX, Auto-Negotiation 5 Power supply connector 0.07 W4S1-05D Programmable Controllers CS1D 61 „Controller Link Units Controller Link Units *1.Use the following special cable for shielded...

https://www.ia.omron.com/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_23_csm1004122.pdf

PDFCSM_CS1W-CRM21_DS_E_9_5 1 CS-series CompoNet Maste...
...munity Conforms to IEC 61000-4-4 2 kV (applied to PLC power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z d...

https://www.ia.omron.com/data_pdf/cat/cs1w-crm21_ds_e_9_5_csm1636.pdf

PDF1 CSM_CS1W-EIP21_EIP21S_DS_E_7_10
...therNet/IP Unit. Network Configurator version 3.74a or higher is included with CX-One version 4.61 or higher. The Network Configurator provides the following functions for building, setting, ...

https://www.ia.omron.com/data_pdf/cat/cs1w-eip21_eip21s_ds_e_7_10_csm1782.pdf

PDFCX-One CS/CJ CPU EtherNet/IP Unit
...1W-EIP21S/CJ1W-EIP21S CS1W-EIP21S CJ1W-EIP21S Existing CS/CJ EtherNet/IP Unit CX-One (version 4.61 or higher) CIP message server Closed FTP server CS/CJ CPU EtherNet/IP Unit CS/CJ CPU EtherNe...

https://www.ia.omron.com/data_pdf/cat/cs1w-eip21s-cj1w-eip21s_r206-e1_4_1_csm1125438.pdf

PDFCSM_CS1W-PROCESS_DS_E_2_3 1 CS-series Process Anal...
...temperature:500°C From electromotive force table −270°C:−6.458 mV 1,372°C: 54.86 mV Full scale: 61.344 Electromotive conversion of temperature coefficient: 61.344 mV×±0.01%/°C =±6.13...

https://www.ia.omron.com/data_pdf/cat/cs1w-process_ds_e_2_3_csm1971.pdf