Primary Contents

Site Search Results

Site Search Product Search
Results 1241 - 1250 of 1956
S8VK-WA Switch Mode Power Supply (240/480/960/2000...
...x.) Vibration resistance *11 10 to 55 Hz, maximum 5 G, 0.42 mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance *11 294 m/s 2 , 3 times each in ±X, ±Y, ±Z dir...

https://www.ia.omron.com/products/family/3753/specification.html

R89F-M AC Free Input Axial Fans/Lineup | OMRON Ind...
...Finger Guard Hexagonal nuts Screws size Qty Model size Qty size Qty R87F-A[]A83 R87F-SET8025 80 x 80 1 R87F-FG80 M4 4 M4 x L38 4 R87T-A[]A83 R87F-A[]A85 R87F-SET8038 80 x 80...

https://www.ia.omron.com/products/family/3759/lineup.html

R89F-D DC Axial Fans/Lineup | OMRON Industrial Aut...
...Finger Guard Hexagonal nuts Screws size Qty Model size Qty size Qty R87F-A[]A83 R87F-SET8025 80 x 80 1 R87F-FG80 M4 4 M4 x L38 4 R87T-A[]A83 R87F-A[]A85 R87F-SET8038 80 x 80...

https://www.ia.omron.com/products/family/3760/lineup.html

K6PM-TH Thermal condition monitoring device/Specif...
...and all Ethernet ports Vibration resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude in X, Y, and Z directions (10 sweeps of 5 min each) Shock resistance 150 m/s 2 , 3 times each...

https://www.ia.omron.com/products/family/3769/specification.html

E2EW Welding Proximity Sensor/Specifications | OMR...
...ase Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s 2 10 times each in X, ...

https://www.ia.omron.com/products/family/3770/specification.html

CP2E CP series CP2E CPU Unit/Specifications | OMRO...
...-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s 2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Shock resistance Conforms to ...

https://www.ia.omron.com/products/family/3777/specification.html

MX-Z2000H-V1 Series Fiber Laser Marker/Lineup | OM...
...th machine instructions (2006/42/EC) EN60204-1. Description Model Button operation part (white) x 2, light-shielding tape, control stop button cover MX-9190 Protective Goggles Use protective ...

https://www.ia.omron.com/products/family/3778/lineup.html

E3AS-HL / F / L Series Distance-settable Photoelec...
...z for 1 min Vibration resistance 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance 500 m/s 2 for 3 times each in X, Y, and Z dire...

https://www.ia.omron.com/products/family/3779/specification.html

S8V-CP DC Electronic Circuit Protector (24 VDC 4 O...
...Power consumption (at input voltage 24 VDC) *3 When all outputs are connected 8 W typ. (at 10 A x 4 CH) 4 W typ. (at 3.8 A x 4 CH) 15 W typ. (at 10 A x 7 CH) When all output...

https://www.ia.omron.com/products/family/3780/specification.html

J7MC Series Manual Motor Starter (Motor Protection...
... start, trips in 4 to 10 seconds at 720% Ie on cold start Instantaneous trip characteristics 13 x Ie max. Power loss (3-phase reference value) Rated current 0.16 to 2.5 A: 6 W Rated current 4...

https://www.ia.omron.com/products/family/3783/specification.html

Results 1241 - 1250 of 1956