Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 4731 - 4740 of 6513
E2EC-M / -Q Stainless Steel Sensing Surface Amplif...
...e current --- 0.8 mA max. Control output Load current 100 mA max. 3 to 50 mA Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m) 3 V max. (Load current: 50 mA, Cable ...

https://www.ia.omron.com/products/family/1865/specification.html

E2A Cylindrical Proximity Sensor/Specifications | ...
... NPN open collector Control output Load current *2 200 mA max. (32 VDC max.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Y...

https://www.ia.omron.com/products/family/1883/specification.html

H3CR-G Solid-state Timer/Specifications | OMRON In...
...urrent Ie AC-15: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 1.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...

https://www.ia.omron.com/products/family/1890/specification.html

H3CR-H Solid-state Timer/Specifications | OMRON In...
..., Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 0.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...

https://www.ia.omron.com/products/family/1891/specification.html

CP1L CP series CP1L CPU Unit/Lineup | OMRON Indust...
...(Length: 5.0 m) XW2Z-500S-CV Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) XW2Z-200S-V Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) XW2Z-500S-V Note: 1. For de...

https://www.ia.omron.com/products/family/1916/lineup.html

CP1L CP series CP1L CPU Unit/Specifications | OMRO...
...5%/0% at 10,000 Hz to 32,800 Hz) Analog input 2 input (Resolution: 1/1000, Input range: 0 to 10 V). Not isolated. CP1L CPU Unit (M/L Type) Type CP1L-M60 (60 points) CP1L-M40 (40 points) CP1L-...

https://www.ia.omron.com/products/family/1916/specification.html

CRT1-[]D08TA(-1) / []D16TA(-1) / []D08TAH(-1) / []...
...Internal I/O common NPN PNP NPN PNP ON voltage 15 VDC min. (between each input terminal and the V terminal) 15 VDC min. (between each input terminal and the G terminal) 10.5 VDC min. (between...

https://www.ia.omron.com/products/family/1919/specification.html

G3PF Solid State Relays with Built-in Current Tran...
...Release time 1/2 of load power source cycle + 1 ms max. Main circuit Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current 10 mA max. (at 200 VAC) 20 mA max. (at 4...

https://www.ia.omron.com/products/family/1924/specification.html

H3CR-A Solid-state Multi-functional Timers/Specifi...
... 30 VDC, Ie: 0.5 A Transistor Output: DC-13: Ue: 30 VDC, Ie: 0.1 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...

https://www.ia.omron.com/products/family/193/specification.html

H7BX Multifunction Counter (DIN 72 × 72)/Specifica...
...dance: 1 kΩ max. (Leakage current at 0 Ω: Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Open (OFF) impedance: 100 kΩ min. Input method (except key protection input) No-voltage ...

https://www.ia.omron.com/products/family/1931/specification.html

Results 4731 - 4740 of 6513