Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 4971 - 4980 of 6521
E2E2 Long-barrel Inductive Proximity Sensor/Specif...
...x. Leakage current 0.8 mA max. Control output Switching capacity 3 to 100 mA Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red...

https://www.ia.omron.com/products/family/451/specification.html

TL-W Flat Inductive Proximity Sensor/Specification...
...% max. Leakage current 0.8 mA max. Control output Load current 3 to 100 mA Residual voltage 3.3 V max. (under load current of 100 mA with cable length of 2 m) Indicators D1 Models: Operation ...

https://www.ia.omron.com/products/family/460/specification.html

TL-N / -Q Rectangular Standard Proximity Sensor/Sp...
...% max. Leakage current 0.8 mA max. Control output Load current 3 to 100 mA Residual voltage 3.3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red...

https://www.ia.omron.com/products/family/462/specification.html

E2C / E2C-H Separate Amplifier Proximity Sensor wi...
...puts Solid- state NPN Load resistance: 4.7 kΩ, 100 mA max. (30 VDC max.) (Residual voltage: 1.5 V max.) PNP Load resistance: 4.7 kΩ, 100 mA max. (30 VDC max.) (Residual voltage: 1.5 ...

https://www.ia.omron.com/products/family/464/specification.html

E6A2-C Incremental 25-mm-dia. Rotary Encoder/Speci...
...: February 18, 2013 Model E6A2-CWZ3E E6A2-CWZ3C E6A2-CWZ5C Power supply voltage 5 VDC -5% to 12 V +10%, ripple (p-p): 5% max. 12 VDC -10% to 24 VDC +15%, ripple (p-p): 5% max. Current consump...

https://www.ia.omron.com/products/family/486/specification.html

E6F-A Absolute 60-mm-dia. Rotary Encoder/Specifica...
...put Output capacity Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage: 0.4 V max. (at sink current of 35 mA) Source current: 35 mA max. Residual voltage: 0.4 V m...

https://www.ia.omron.com/products/family/496/specification.html

S3D2 Sensor Controller/Specifications | OMRON Indu...
...ransistor output (with sinking current of 18 mA min.) or contact output Input signals ON 0 to 4 V (5 mA min.) OFF 8 to 12 V (2 mA max.) Short-circuit current 11 mA TYP (18 mA max.) M...

https://www.ia.omron.com/products/family/571/specification.html

K3MA-L Temperature Meter/Specifications | OMRON In...
... and case. Insulation provided between inputs, outputs, and power supply. Noise immunity ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise wi...

https://www.ia.omron.com/products/family/589/specification.html

S8VS Switch Mode Power Supply (15/30/60/90/120/180...
...less terminal block) 15 W 100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *3) 5 V 2.0 A Yes S8VS-01505 *1 --- 12 V 1.2 A Yes S8VS-01512 24 V 0.65 A Yes S8VS-...

https://www.ia.omron.com/products/family/807/lineup.html

R87F / R87T AC Axial Fans/Lineup | OMRON Industria...
...age fluctuation range (%): 85% to 110% rated voltage Frequency (Hz): 50/60 Model Rated voltage (V) Rated current (A) * Rated input (W) * Rated rotational speed (r/min) * Maximum flow rate (m ...

https://www.ia.omron.com/products/family/809/lineup.html

Results 4971 - 4980 of 6521