S8VS Switch Mode Power Supply (15/30/60/90/120/180...
...less terminal block) 15 W 100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *3) 5 V 2.0 A Yes S8VS-01505 *1 --- 12 V 1.2 A Yes S8VS-01512 24 V 0.65 A Yes S8VS-...

https://www.ia.omron.com/products/family/807/lineup.html

R87F / R87T AC Axial Fans/Lineup | OMRON Industria...
...age fluctuation range (%): 85% to 110% rated voltage Frequency (Hz): 50/60 Model Rated voltage (V) Rated current (A) * Rated input (W) * Rated rotational speed (r/min) * Maximum flow rate (m ...

https://www.ia.omron.com/products/family/809/lineup.html

R87B Box Fan/Lineup | OMRON Industrial Automation
...d Ordering Information for set model Airflow Direction: In Item Num- ber of fans Rated voltage (V) Permitted voltage fluctuation range (%) Fre- quen- cy (Hz) Rated rotational speed (r/min) * ...

https://www.ia.omron.com/products/family/810/lineup.html

K2CM Motor Protective Relay/Lineup | OMRON Industr...
...former Model Voltage specification Secondary power consumption SE-PT400 Primary side 380 to 480 V (wide power supply range) 7VA Secondary side 190 to 240 V (wide power supply range) ...

https://www.ia.omron.com/products/family/841/lineup.html

K2CM Motor Protective Relay/Specifications | OMRON...
...etween contact poles) Permissible impulse voltage Current reverse-phase detection models: 6,000 V (between current-carrying terminals and mounting panel) 4,500 V (between current-car...

https://www.ia.omron.com/products/family/841/specification.html

SE Motor Protective Relay/Lineup | OMRON Industria...
...ected. Model Voltage specification Secondary power consumption SE-PT400 Primary side 380 to 480 V (wide power supply range) 7 VA Secondary side 190 to 240 V (wide power supply range)...

https://www.ia.omron.com/products/family/842/lineup.html

SE Motor Protective Relay/Specifications | OMRON I...
...f same pole Withstand voltage Refer to the table below. Lighting impulse withstand voltage 6000 V max. between the entire circuits and the mounting panel 4500 V max. between contact ...

https://www.ia.omron.com/products/family/842/specification.html

SAO Current Sensor/Specifications | OMRON Industri...
...uits 1,000 VAC for 1 min between contacts of same pole Lighting impulse withstand voltage 6,000 V max. between electric circuits and the mounting panel 4,500 V max. between contact c...

https://www.ia.omron.com/products/family/843/specification.html

SDV Voltage Sensor/Lineup | OMRON Industrial Autom...
...l power supply voltage Input DC DC or AC (selectable) Input voltage range 4 to 240 mV 0.2 to 12 V 10 to 300 V 24 VDC SDV-FL2 SDV-FM2 SDV-FH2 48 VDC SDV-FL3 SDV-FM3 SDV-FH3 100/110 VD...

https://www.ia.omron.com/products/family/847/lineup.html

SDV Voltage Sensor/Specifications | OMRON Industri...
...25, 200/220 VDC *; 100/110, 200/220/240 VAC (50/60 Hz) SDV-FM[] DC or AC (selectable) 0.2 to 12 V (0.2 to 0.6 V, 0.5 to 1.5 V, 1 to 3 V, 2 to 6 V, 4 to 12 ...

https://www.ia.omron.com/products/family/847/specification.html