H7BX Multifunction Counter (DIN 72 × 72)/Lineup | ...
... Output type Supply voltage 1-stage 2-stage 12 VDC Contact and NPN transistor output 100 to 240 VAC H7BX-A H7BX-AW 24 VAC/12 to 24 VDC H7BX-AD1 H7BX-AWD1 Accessories (Order Separatel...

https://www.ia.omron.com/products/family/1931/lineup.html

A4EG Enabling Grip Switch/Specifications | OMRON I...
...ch. UL/CSA (UL 508, CSA C22.2 No.14), CCC (GB/T 14048.5) • 24 VDC, 0.3 A (inductive load) • 125 VAC, 1 A (resistive load) Ratings Section Enabling switch Emergency stop switch (A4EG-BE2R041 o...

https://www.ia.omron.com/products/family/1935/specification.html

H3CR-F Solid-state Timer/Lineup | OMRON Industrial...
...s Supply voltage 0.05 s to 300 h models 11-pin models 8-pin models Flicker OFF start 100 to 240 VAC/ 100 to 125 VDC H3CR-F 100-240AC/100-125DC H3CR-F8 100-240AC/100-125DC 24 to 48 ...

https://www.ia.omron.com/products/family/194/lineup.html

S8AS Smart Power Supply/Lineup | OMRON Industrial ...
... Number of output branches Commu- nications functions Parameter settings Model 240 W 100 to 240 VAC 24 V 3.8 A 10 A 6 branch outputs None Changeable S8AS-24006 None Not changeable S8AS-24006N...

https://www.ia.omron.com/products/family/1948/lineup.html

ZJ-BAS Ionizer (Digital Bar Type)/Lineup | OMRON I...
...5 m ZJ-BAS-FC15A 20 m ZJ-BAS-FC20A AC Adapter Appearance Specifications Model Input: 100 to 240 VAC Output: 24 VDC × 2 ZJ-BAS-PS01 Linking Bracket Set Appearance Contents Model Linking Bracke...

https://www.ia.omron.com/products/family/1959/lineup.html

ZJ-BAS Ionizer (Digital Bar Type)/Specifications |...
...Charge plate monitor: 150 × 150 mm, 20 pF AC Adaptor Model ZJ-BAS-PS01 Input voltage 100 to 240 VAC Input current 1.2 A max. Output voltage 24 VDC Output current 3.75 A max. Number of output ...

https://www.ia.omron.com/products/family/1959/specification.html

H3Y Solid-state Timer/Lineup | OMRON Industrial Au...
...ration/ self-resetting DPDT (for power switching) 0.04 s to 3 h 24, 100 to 120, 200 to 230, 240 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC H3Y-2 H3Y-2-0 4PDT H3Y-4 * H3Y-4-0 * Note: Sock...

https://www.ia.omron.com/products/family/196/lineup.html

H3YN Solid-state Timer/Lineup | OMRON Industrial A...
...ange model (0.1 s to 10 min) Long-time range model (0.1 min to 10 h) 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC DPDT H3YN-2 H3YN-21 4PDT H3YN-4 *1 H3YN-41 *1 24 VDC 4PDT ...

https://www.ia.omron.com/products/family/197/lineup.html

H3RN Solid-state Timer/Lineup | OMRON Industrial A...
...mit contact Short-time range model (0.1 s to 10 min) Long-time range model (0.1 min to 10 h) 24 VAC; 12, 24 VDC SPDT H3RN-1 H3RN-11 DPST-NO H3RN-2 H3RN-21 Accessories (Order Separately) Conne...

https://www.ia.omron.com/products/family/198/lineup.html

H3RN Solid-state Timer/Specifications | OMRON Indu...
...ble) 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs max. selectable) Rated supply voltage *2 24 VAC (50/60 Hz); 12, 24 VDC Pin type Plug-in Operating mode ON-delay, interval, flicker OFF-star...

https://www.ia.omron.com/products/family/198/specification.html