Primary Contents

Site Search Results

Site Search Product Search
Results 551 - 560 of 1179
Further Information of General Purpose Relays | OM...
...two contacts are not always going to turn ON/OFF at the same time (there may be a slight delay) so one contact will bear the full load momentarily. What are twin-contact relay models suitable...

https://www.ia.omron.com/support/guide/36/further_information.html

explanation_of_terms.html
...teristics of fuses and the operating characteristics of breakers, and select fuses and breakers so that external fuses will not burn out and breakers will not be activated by the inrush curre...

https://www.ia.omron.com/support/guide/22/explanation_of_terms.html

troubleshooting.html
... Adjuster Do not apply unnecessarily strong force on the Output Voltage Adjuster (V.ADJ). Doing so may damage the V.ADJ. Make sure that the end of the screwdriver used to adjust the setting d...

https://www.ia.omron.com/support/guide/22/troubleshooting.html

explanation_of_terms.html
...cation range from standard to high-capacity loads. The fixed rivet contact is usually processed so that it has a groove to eliminate compounds that may be generated as a result of switching. ...

https://www.ia.omron.com/support/guide/29/explanation_of_terms.html

Overview of Limit Switches Technical Guide for Lim...
...-ring or a rubber diaphragm is used for sealing. The rubber seal is not externally exposed, and so resistance is provided against cutting debris from machine tools, but sand and fine shavings...

https://www.ia.omron.com/support/guide/30/overview.html

explanation_of_terms.html
...ater; however, at water treatment plants it may refer to water at a stage before it is purified so it has a broader meaning than purified water. Sewage (Sewer) Better described as a wastewate...

https://www.ia.omron.com/support/guide/33/explanation_of_terms.html

troubleshooting.html
...ty. Tighten terminal screws. 3. If there are lime deposits or grease, it will not conduct well, so remove it and clean. 4. If the electrodes are too far apart, the inter-electrode resistance ...

https://www.ia.omron.com/support/guide/33/troubleshooting.html

troubleshooting.html
...rbon, or other foreign matter 2. Is the contact surface corroded? ・ Contact sulphurization from SO 2 and H 2 S 3. Is there a mechanical cause? ・ Terminal displacement, contact displacement,...

https://www.ia.omron.com/support/guide/36/troubleshooting.html

Further Information of Photoelectric Sensors | OMR...
...objects with high gloss or objects covered with glossy film. If this occurs, install the Sensor so that it is at an angle off perpendicular to the sensing object. Retro-reflective Sensors wit...

https://www.ia.omron.com/support/guide/43/further_information.html

explanation_of_terms.html
...n with an electromagnetic brake. However, there is no holding torque when the motor is stopped, so a mechanical brake must be applied to hold the motor. Dynamic brake is used for mechanical p...

https://www.ia.omron.com/support/guide/14/explanation_of_terms.html

Results 551 - 560 of 1179