MY Miniature Power Relays/Specifications | OMRON I...
... MY4ZN-CR Item Rated current (mA) Coil resistance (Ω) Coil inductance (H) Must operate voltage (V) Must release voltage (V) Maximum voltage (V) Power consumption (VA, W) Rat...

https://www.ia.omron.com/products/family/948/specification.html

LY Bi-power Relays/Specifications | OMRON Industri...
...Models Item Rated current (mA) Coil resist- ance (Ω) Coil inductance (H) Must- operate voltage (V) Must- release voltage (V) Maximum voltage (V) Power con- sumption (VA, W) ...

https://www.ia.omron.com/products/family/949/specification.html

Further Information of Solid-state Relays | OMRON ...
...220 A. The value of the protective resistance R is obtained from the following formula: R > 220 V x √2/200 A = 1.4 Ω Considering the circuit current and ON time, insert the protective resista...

https://www.ia.omron.com/support/guide/18/further_information.html

Further Information of Level Switches | OMRON Indu...
...ly there should be no difference. For example, if the potential difference was measured to be 3 V, when the common line is connected to ground, this voltage will drop down to as low as 0...

https://www.ia.omron.com/support/guide/33/further_information.html

PDFSensors Switches Safety Components Relays Control ...
... to zero-phase. The zero cross function turns ON the SSR when the AC load voltage is close to 0 V, thereby suppressing the noise generated by the load current when the load current rises quic...

https://www.ia.omron.com/data_pdf/guide/18/ssr_tg_e_9_12.pdf

PDFSensors Switches Safety Components Relays Control ...
...ak value) Time * H5AN series 100 to 240 VAC 264 VAC 23 A 1 ms 100 VDC 110 VDC 8 A 2 ms 12 to 24 V DC 26.4 VDC 15 A 6.5 ms H5CN series 100 to 240 VAC 264 VAC 800 mA 1 ms 12 to 48 VDC 52.8 VDC ...

https://www.ia.omron.com/data_pdf/guide/19/timer_timeswitch_tg_e_7_5.pdf

PDFSensors Switches Safety Components Relays Control ...
...according to the available input voltage. Output Capacity Output capacity (W) = Output voltage (V)×Load current (I) Select the Power Supply so that the maximum load capacity will be lower tha...

https://www.ia.omron.com/data_pdf/guide/22/powersupply_tg_e_8_4.pdf

PDFSensors Switches Safety Components Relays Control ...
... operating condition (Z Switch) Force relation (Z Switch) Double-throw (Z Switch) Double-throw (V Switch) Double-break (WL Switch) Free position Operating position Total travel position Fixed...

https://www.ia.omron.com/data_pdf/guide/29/microswitch_tg_e_3_4.pdf

PDFSensors Switches Safety Components Relays Control ...
...es Relay No current flows. 8 VAC Relay Contacts To contactor b c a E1 X E3 61F-11N Relay Unit 8 V U 200 V 0 V 24 V No current flows. Relay Contacts To contactor b c...

https://www.ia.omron.com/data_pdf/guide/33/levelapparatus_tg_e_8_2.pdf

PDFSensors Switches Safety Components Relays Control ...
...but less than 0.1 10 0.1 or higher but less than 1 100 1 or higher 1,000 Contact resistance = I V (Ω) V A (DC or AC) :Ammeter :Voltmeter :Variable resistor Power supply Terminal...

https://www.ia.omron.com/data_pdf/guide/36/generalrelay_tg_e_10_7.pdf

Results 5751 - 5760 of 6485