Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 5731 - 5740 of 6516
R88M-K, R88D-KN[]-ML2 G5-series AC Servomotors/Ser...
...ity 0.4 KVA 0.4 KVA 0.5 KVA 0.9 KVA Power supply voltage Single-phase 100 to 120 VAC (85 to 132 V), 50/60 Hz Rated current 1.7 A 2.6 A 4.3 A 7.6 A Heat value *1 11 W 16.6 W 21 W 25 W Control ...

https://www.ia.omron.com/products/family/2627/specification.html

R88M-K, R88D-KN[]-ECT G5 Series AC Servomotor/Serv...
...ncoder Straight shaft with key and tap Voltage Rated output Without oil seals Without brake 100 V 50 W R88M-K05030H-S2 100 W R88M-K10030L-S2 200 W R88M-K20030L-S2 400 W R88M-K40030L-S2 2...

https://www.ia.omron.com/products/family/2644/lineup.html

R88M-K, R88D-KN[]-ECT G5 Series AC Servomotor/Serv...
...ity 0.4 KVA 0.4 KVA 0.5 KVA 0.9 KVA Power supply voltage Single-phase 100 to 120 VAC (85 to 132 V) 50/60 Hz Rated current 1.7 A 2.6 A 4.3 A 7.6 A Heat value *1 11 W 16.6 W 21 W 25 W Control c...

https://www.ia.omron.com/products/family/2644/specification.html

E3X-SD / NA Simple Fiber Amplifier Unit/Specificat...
...ls High-speed detection models Water-resistant models Model E3X-SD[] E3X-NA[] E3X-NA[]F E3X-NA[]V Light source (wavelength) Red, 4-element LED (625 nm) Red, 4-element LED (624 nm) Red, 4-elem...

https://www.ia.omron.com/products/family/2647/specification.html

CJ2M-CPU3[] / CPU1[] / MD21[] CJ-series CJ2M CPU U...
...VDC +10%/-15% RS-422A or RS-422 line driver (conforming to AM26LS31), Power supply voltage of 5 V ±5% Input impedance 3.6 kΩ 4.0 kΩ --- Number of circuits 1 common,1 circuit ON voltage/curren...

https://www.ia.omron.com/products/family/2712/specification.html

NJ501-[][][][] NJ-Series NJ501 CPU Units/Specifica...
...ondition expression for variable is met. System Service Tasks (NJ501-R[][][]) Maximum number of V+ Tasks 64 Setup System Service Monitoring Settings The execution interval and the percentage ...

https://www.ia.omron.com/products/family/3075/specification.html

Sysmac Studio Ver.1.[][] Automation Software Sysma...
... Windows 11 (64-bit) Windows 10 version 1607 or higher (64-bit)/ Windows 11 (64-bit) CPU *2 DOS/V (IBM AT compatible machines) personal computers equipped with Intel® Core™ i5 M520 (2.4 GHz) ...

https://www.ia.omron.com/products/family/3077/specification.html

E3X-HD Smart Fiber Sensor/Specifications | OMRON I...
...s of 4 to 16 Amplifier Units: 20mA max. Residual voltage: At load current of less than 10 mA: 1 V max., At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max. - Protectio...

https://www.ia.omron.com/products/family/3103/specification.html

E3NX-FA Smart Fiber Amplifier Units/Specifications...
...of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. External in...

https://www.ia.omron.com/products/family/3161/specification.html

NX-ID / IA / OD / OC / MD NX-series Digital I/O Un...
...Maximum inrush current 4.0 A/point, 10 ms max. Leakage current 0.1 mA max. Residual voltage 1.5 V max. ON/OFF response time 300 ns max./300 ns max. Dimensions 12 (W) x 100 (H) x 71 (D) Isolat...

https://www.ia.omron.com/products/family/3185/specification.html

Results 5731 - 5740 of 6516