Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 701 - 710 of 13551
ZJ-SD Smart Electrostatic Sensor/Specifications | ...
... 4, 8, 16, 32, 64, 128, 256, 512, or 1,024 Linear output *2 Current output: 4 to 20 mA/FS, Max. load resistance: 300 Ω Voltage output: ±4 V (±5 V, 1 to 5 V *3), Output impedance: 100 Ω Judgme...

https://www.ia.omron.com/products/family/1736/specification.html

ZN-A Air Clean Units/Specifications | OMRON Indust...
...dby) Trouble Clogged filter (ZN-A6112P only) 30 VDC, 50 mA max. Residual voltage: 1 V max. with load current of 10 mA, 2 V max. with load current of 50 mA. Applicable Ionizer Unit (O...

https://www.ia.omron.com/products/family/1828/specification.html

G3PF Solid State Relays with Built-in Current Tran...
...Description G3PF-225B-CTB DC24 Solid State Relays with Built-in Current Transformer, Applicable load: 25 A at 100 to 240 VAC, 2 alarm output, With zero cross function, Screwless clamp termina...

https://www.ia.omron.com/products/family/1924/itemlist/

F3W-E Picking Sensor/Specifications | OMRON Indust...
...ption Emitter: 40 mA max., Receiver: 40 mA max. Control output NPN or PNP open collector output Load power supply: 30 VDC, Load current: 100 mA max. (Residual voltage: 1.8 V max.) Da...

https://www.ia.omron.com/products/family/1932/specification.html

E2V-X[] All Metals and Long-distance Types/Specifi...
...on 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) Control output Load current Open-collector output, 100 mA max. Residual voltage 2 V max. (Load curren...

https://www.ia.omron.com/products/family/1937/specification.html

E32-L11FP / L1[]FS, E3X-DA[][]TG-S Wet Process Sen...
... 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Control output Load power supply voltage: 26.4 VDC, load current: 50 mA max.; residual voltage: 1 V m...

https://www.ia.omron.com/products/family/1985/specification.html

EE-SPX613 Pipe-mounting Liquid Level Photomicrosen...
...x. Current consumption Average: 30 mA max., Peak: 80 mA max. Control output NPN open collector: Load power supply voltage: 5 to 24 VDC Load current: 100 mA max. OFF current: 0.5 mA m...

https://www.ia.omron.com/products/family/287/specification.html

A30NK Key-type Selector Switches/Specifications | ...
...ation Standards UL1059 and UL486E (Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 38...

https://www.ia.omron.com/products/family/3449/specification.html

E3S-CL Distance-settable Photoelectric Sensor with...
...voltage 10 to 30 VDC; ripple: 10% max. Current consumption 35 mA max. 50 mA max. Control output Load power supply voltage: 30 VDC max., Load current: 100 mA max. Residual voltage: NP...

https://www.ia.omron.com/products/family/415/specification.html

E3Z-LS Distance-settable Photoelectric Sensor/Spec...
...voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max. Current consumption 30 mA max. Control output Load power supply voltage: 26.4 VDC max., Load current: 100 mA max. (residual voltage ...

https://www.ia.omron.com/products/family/420/specification.html

Results 701 - 710 of 13551