Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 731 - 740 of 6516
CK3W-MD71[]0 Digital I/O Unit/Specifications | OMR...
...Maximum inrush current 4.0 A/point, 10 ms max. Leakage current 0.1 mA max. Residual voltage 1.0 V max. ON/OFF response time 0.1 ms max./0.8 ms max. Isolation method Isolation by Photocoupler ...

https://www.ia.omron.com/products/family/3772/specification.html

CK3W-AD[]100 Analog Input Unit/Lineup | OMRON Indu...
... Analog Input Units Product name Input range Number of inputs Model Analog Input Unit -10 to 10 V 4 CK3W-AD2100 8 CK3W-AD3100 Wiring Applicable Wires The wires that you can connect to the ter...

https://www.ia.omron.com/products/family/3773/lineup.html

CK3W-AD[]100 Analog Input Unit/Specifications | OM...
...fications Analog input Input method Differential or single-ended input *1 Input range -10 to 10 V Absolute maximum rating ±12 V (GND reference) Input impedance 1 MΩ min. Resolution 1...

https://www.ia.omron.com/products/family/3773/specification.html

CK3W-EX / CK5W-EX Expansion Master Unit and Expans...
... Unit, be sure to use the following cable. CK3W-CAX003A (0.3 m) Power consumption CK3W-EXM01: 5 V 0.4 W max. CK5W-EXS01: 5 V 0.2 W max. CK3W-EXS02: 5 V 0.2 W max. Dimensions...

https://www.ia.omron.com/products/family/3774/specification.html

J7TC Series Thermal overload relay/Specifications ...
...s than 2 hours) *1 Auxiliary circuit rating Ratings based on IEC 60947-5-1 Rated voltage range (V) 24 100-120 200-240 380-440 500-600 Rated operational current (A) AC-15 (Coil load) NC contac...

https://www.ia.omron.com/products/family/3782/specification.html

i4L SCARA Robot/Lineup | OMRON Industrial Automati...
...lacement Bellows 350 mm quill length. 22862-000F Encoder Backup Battery Pack Includes three 3.6 V batteries. 20269-000F*1 *1 Equipment supplied with all robots. last update: September 8, 2022...

https://www.ia.omron.com/products/family/3812/lineup.html

i4H SCARA Robots/Lineup | OMRON Industrial Automat...
...ws Replacement Kit 410 mm quill length. 19464-104F Encoder Backup Battery Pack Includes two 3.6 V batteries. 19238-000F*1 *1 Equipment supplied with all robots. *2 Additional equipment suppli...

https://www.ia.omron.com/products/family/3822/lineup.html

CK3W-GC[][]00 Laser Interface Unit/Specifications ...
... TCR output) Rated voltage 5 VDC Maximum output current 20 mA Output voltage (for H output) 3.8 V min. Output voltage (for L output) 0.55 V max. Response time 100 ns max. Maximum tra...

https://www.ia.omron.com/products/family/3835/specification.html

VT-S1080 PCB Inspection System/Specifications | OM...
...D) x 1500(H)mm (excluding tower lamp and monitor) Weight Approx. 1240Kg Power supply 200 to 240 V AC (Single phase); Voltage fluctuation range ±10% 50/60Hz Rated power 2.0 kVA (Maximum curren...

https://www.ia.omron.com/products/family/3839/specification.html

V440-F 5-Megapixel C-Mount Code Reader/Specificati...
...0° Skew Angle (β) *3 ±30° Tilt Angle (γ) *3 ±180° Image Resolution, Pixel Size 2464 (H) x 2056 (V) - 3.45 μm Pixel Size Color / Monochrome Monochrome CMOS Shutter Global Shutter Frames per Se...

https://www.ia.omron.com/products/family/3847/specification.html

Results 731 - 740 of 6516