Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 5741 - 5760 of 41756
faq01119

...he open collector operates depending on whether standard voltage is high or low compared to the input voltage. The effect of noise will cause the open collector signal to turn ON or OFF. Nois...

https://www.ia.omron.com/support/faq/answer/26/faq01119/

faq01132

.... EXCLUSIVE OR Instruction (XORW) Specifications 1.An EXCLUSIVE OR of the corresponding bits in input 1 and input 2 are taken and the results are output to the result word, R. 2.As c...

https://www.ia.omron.com/support/faq/answer/26/faq01132/

faq01468

...y Contents Question How do I write a program to delay turning ON a work bit for 1 scan after an input A turns ON and keep the work bit ON for only 1 scan when using a CS/CJ-series Programmabl...

https://www.ia.omron.com/support/faq/answer/26/faq01468/

faq01470

...y Contents Question How do I write a program to delay turning ON a work bit for 1 scan after an input A turns ON and keep the work bit ON for only 1 scan? Answer  As shown in Figure 1, the p...

https://www.ia.omron.com/support/faq/answer/26/faq01470/

faq01475

...o I program ON/OFF delays? Answer  Operation Specifications and Data Trace Results CIO 000000: Input A (CIO 0.00) CIO 000200: Output B (CIO 2.00) *Output B (CIO 2.00) turns ON 3.0 s aft...

https://www.ia.omron.com/support/faq/answer/26/faq01475/

faq01477

...If the ON and OFF time is 0.5 s or 0.1 s, a Clock Pulse Bit (P_ls and P_0_2s) can be used as an input. The following method can be used to create a flicker program that outputs a pulse-train ...

https://www.ia.omron.com/support/faq/answer/26/faq01477/

faq01479

...tion How do I program a one-shot output? Answer  In a one-shot program, as long as the trigger input stays ON for longer than a certain time (see note), the output bit will be turned ON for ...

https://www.ia.omron.com/support/faq/answer/26/faq01479/

faq01621

...program an ON delay? Answer  Operation Specifications and Data Trace Results CIO 000000: Start input bit (CIO 0.00) CIO 000001: Reset input bit (CIO 0.01) W00000: Work bit to store ...

https://www.ia.omron.com/support/faq/answer/26/faq01621/

faq01823

...en in Table 1. Instruction Application and characteristics --|↑|-- Can be used only with LD/AND input instructions. DIFU A work bit is required to process the differentiated status. UP A work...

https://www.ia.omron.com/support/faq/answer/26/faq01823/

faq02069

...in the ladder program in Figure 1, both BINARY ADD instructions and BCD ADD instructions can be input and displayed in decimal form. The data conversion function of CX-Programmer makes this p...

https://www.ia.omron.com/support/faq/answer/26/faq02069/

faq02260

... specifications. *When one of the pushbutton switches from 1 to 32 is pressed, the two words of input data (4-digit BCD data) will be stored in D100 to D131 as shown in the following example....

https://www.ia.omron.com/support/faq/answer/26/faq02260/

faq02755

...he KEEP instruction. Figure 1 Basic Functions of the KEEP Instruction In Figure 1, when the set input bit (CIO 0.00) is input as a pulse signal as shown in Figure 2, the output bit (...

https://www.ia.omron.com/support/faq/answer/26/faq02755/

faq02853

...nd CVM1/CV-series Programmable Controllers CPU Units can accept the differentiation option with input commands. With other models, use DIFU/DIFD, as shown in diagram 2. CJ2 Introducing the Fl...

https://www.ia.omron.com/support/faq/answer/26/faq02853/

faq02892

...uestion When monitoring a ladder diagram, sometimes the output does not turn ON even though the input condition is ON, or the output turns ON even though the input condition is OFF. ...

https://www.ia.omron.com/support/faq/answer/26/faq02892/

FAQ02057 for Basic Switches | OMRON Industrial Aut...

... Environment/Application The load does not turn ON when the Switch is pressed. Why is this? The input is not entered into the Programmable Controller when the switch is pressed. Why is this? ...

https://www.ia.omron.com/support/faq/answer/29/faq02057/

FAQ02082 for Basic Switches | OMRON Industrial Aut...

... Environment/Application The load does not turn ON when the Switch is pressed. Why is this? The input is not entered into the Programmable Controller when the switch is pressed. Why is this? ...

https://www.ia.omron.com/support/faq/answer/29/faq02082/

FAQ02094 for Basic Switches | OMRON Industrial Aut...

... Environment/Application The load does not turn ON when the Switch is pressed. Why is this? The input is not entered into the Programmable Controller when the switch is pressed. Why is this? ...

https://www.ia.omron.com/support/faq/answer/29/faq02094/

faq02112

... Environment/Application The load does not turn ON when the Switch is pressed. Why is this? The input is not entered into the Programmable Controller when the switch is pressed. Why is this? ...

https://www.ia.omron.com/support/faq/answer/29/faq02112/

FAQ02145 for Basic Switches | OMRON Industrial Aut...

... Environment/Application The load does not turn ON when the Switch is pressed. Why is this? The input is not entered into the Programmable Controller when the switch is pressed. Why is this? ...

https://www.ia.omron.com/support/faq/answer/29/faq02145/

FAQ02182 for Basic Switches | OMRON Industrial Aut...

... Environment/Application The load does not turn ON when the Switch is pressed. Why is this? The input is not entered into the Programmable Controller when the switch is pressed. Why is this? ...

https://www.ia.omron.com/support/faq/answer/29/faq02182/

Results 5741 - 5760 of 41756

Select Country in