Site Search | Product Search | IA Global Search |
...Index Features Lineup Specifications Dimensions Catalog last update: July 5, 2021 Ratings Power input Model G9SX-AD322-[]/ADA222-[] G9SX-BC202-[] G9SX-EX-[] Rated supply voltage 24 VDC Operat...
https://www.ia.omron.com/products/family/1524/specification.html
...es Ambient storage temperature -25°C to 65°C Mounting method M4 screw mounting Weight 50 g max. Input Specifications 32-point Inputs Terminals with Connectors Model DRT2-ID32B DRT2-ID32BV DRT...
https://www.ia.omron.com/products/family/1526/specification.html
...ommon Operating Memory Area Words allocated in CPU Bus Unit Area: 25 words (15 output words, 10 input words) Axis Operating Memory Area Allocated in one of the following areas (user-specified...
https://www.ia.omron.com/products/family/1528/specification.html
.../DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input No-voltage contact, voltage pulse, open collector External power supply 12 VDC 10%, 80 mA...
https://www.ia.omron.com/products/family/1539/specification.html
... Internal circuit power supply 24 VDC, 230 mA 24 VDC, 280 mA I/O power supply *2 24 VDC, 40 mA (Input) 120 mA (Output) 24 VDC, 80 mA (Input) 150 mA (Output) Overvoltage category II N...
https://www.ia.omron.com/products/family/1625/specification.html
...CPU Unit CJ1M-CPU13 *1 1 0.580 A --- I/O Control Unit CJ1W-IC101 1 0.020 A --- Basic I/O Units (Input Units) CJ1W-ID211 2 0.080 A --- CJ1W-ID231 2 0.090 A --- Basic I/O Units (Output Units) C...
https://www.ia.omron.com/products/family/1639/specification.html
...cifications Dimensions Catalog last update: April 1, 2014 CJ1W-PTS15 Isolated-type Thermocouple Input Unit Item Specifications Model CJ1W-PTS15 Applicable Controller CJ Series Unit classifica...
https://www.ia.omron.com/products/family/1644/specification.html
... OMRON representative for further details and applicable conditions for these standards. Analog Input Units Unit type: CJ1 Special I/O Units Signal range selection: Set separately for ea...
...Automation Features Lineup Specifications Dimensions Catalog last update: March 11, 2019 Analog Input Units CJ1W-AD041-V1/AD081-V1/AD042 Item CJ1W-AD041-V1 CJ1W-AD081-V1 CJ1W-AD042 Unit type ...
https://www.ia.omron.com/products/family/1645/specification.html
...data exchange with CPU Unit Special I/O Unit Area (Operation Data) 10 words/Unit Direct Current Input Unit to CPU Unit: All process values, process value alarms (LL, L, H, HH), rate-of-change...
https://www.ia.omron.com/products/family/1646/specification.html
...DIP switch at the front of the Unit. By default the Counters are set to Simple Counter. Maximum Input Frequency 500 kHz Maximum Response Time 0.5 ms Signals per Counter Phase A, B and Z Digit...
https://www.ia.omron.com/products/family/1649/specification.html
...sters 4 Reads multiple words from the CIO, Work, Holding, or Auxiliary Area of I/O memory. Read Input Registers 5 Writes a bit in I/O memory. Write Single Coil 6 Writes a word in the DM or EM...
https://www.ia.omron.com/products/family/1651/specification.html
...U-W Voltage (for driving SSR) E5CS-Q1KJDU-W --- Case Color: Light Gray, Thermistor or Universal-input, Power Supply Voltage: 100 to 240 VAC Size Type Control modes Alarms Outputs Model with t...
...of rated supply voltage Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE[...
https://www.ia.omron.com/products/family/166/specification.html
...959): 20 words per Unit Special I/O Unit Area in DM Area (D20000 to D29599): 200 words per Unit Input specifications Number of analog inputs 4 8 16 Input signal range *5 1 to 5 V 0 t...
https://www.ia.omron.com/products/family/1666/specification.html
...Analog Output Unit: Analog output values for each output Analog Output Unit to CPU Unit: Answer input values for each output, output disconnection DM Area words allocated to Special I/O Units...
https://www.ia.omron.com/products/family/1669/specification.html
...I/O Unit Analog output Peak value hold Conversion Enable Bit Analog I/O Unit to CPU Unit Analog input Input disconnection detection Alarm flags Internal Special I/O Unit DM Area (D20...
https://www.ia.omron.com/products/family/1670/specification.html
...sation) Current consumption Name Model Current consumption (power) 5 V 26 V Isolated-type Pulse Input Unit CS1W-PPS01 0.20 A (1.00 W) 0.16 A (4.2 W) (Reference) Maximum current and total powe...
https://www.ia.omron.com/products/family/1671/specification.html
...ailure. Ethernet (LAN) ports One port (10/100Base-TX, RJ45 Modular Connector) UPS power failure input None (UPS connected to COMM port.) Settings and operation Unit number switch (UNIT) Rotar...
https://www.ia.omron.com/products/family/1732/specification.html
...ts: 1 MHz, 2 axes 100 kHz, 2 axes DC power supply Transistor output (sinking) 12 + line- driver input, 2 axes 8 + line- driver output, 2 axes CP1H-Y20DT-D Note: 1. CP1H PLCs are supported by ...