Site Search | Product Search | IA Global Search |
... now be connected with a short bar in the G70D-SOC08. • No tools are required to remove Relays, so Relay replacement is easier than ever. • The attached terminal cover prevents shocks. • Equi...
https://www.fa.omron.co.jp/data_pdf/cat/g70d-soc08_ds_e_5_1_csm1046356.pdf
...atches on the expansion terminal block into the mounting holes in the terminal block, and slide so that the block will not come off. • Tighten the mounting screw to fasten. (2) Attachment Ter...
https://www.fa.omron.co.jp/data_pdf/cat/g70d-vsoc16_-vfom16_ds_e_3_1_csm1046358.pdf
...e Transportation • Do not transport the I/O Relay Terminal under the following locations. Doing so may occasionally result in damage, malfunction, or deterioration of performance characterist...
https://www.fa.omron.co.jp/data_pdf/cat/g70v_j215-e1_2_19_csm1050154.pdf
...ts of 6 A or more when using this product in combination with the P7S-14F/14P/14A Socket. Doing so may result in fire. Use this product in combination with the P7S-14F-END/14P-E. Precautions ...
https://www.fa.omron.co.jp/data_pdf/cat/g7s-_-e_ds_e_7_3_csm1272.pdf
... • Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. • Do not insert more than one wire into each terminal inse...
https://www.fa.omron.co.jp/data_pdf/cat/g7sa_j120-e1_12_12_csm1269.pdf
...for power supply. Connect the power source to the A1 and A2 terminals. DC inputs have polarity, so A1 should be connected to the positive side and A2 to the negative side. Power supply input ...
https://www.fa.omron.co.jp/data_pdf/cat/g9sa-p_f106-e1_6_2_csm1070131.pdf
...for power supply. Connect the power source to the A1 and A2 terminals. DC inputs have polarity, so A1 should be connected to the positive side and A2 to the negative side. Safety input 1 T11,...
https://www.fa.omron.co.jp/data_pdf/cat/g9sa_ds_e_11_15_csm1281.pdf
...for power supply. Connect the power source to the A1 and A2 terminals. DC inputs have polarity, so A1 should be connected to the positive side and A2 to the negative side. Safety input 1 *1 T...
https://www.fa.omron.co.jp/data_pdf/cat/g9sb_ds_e_6_7_csm1282.pdf
...1 PLC etc. Motor controller 13 23 37 47 Note: The lock release enable signal must be configured so that it should turn ON after dangerous movement is stopped and safety is ensured for the doo...
https://www.fa.omron.co.jp/data_pdf/cat/g9se_j198-e1_4_7_csm1040781.pdf
...ures are added to your set-up. Three different models are available, with a range of I/O lines, so you can choose the most suitable for your system. Each one is compatible with the Omron conf...
https://www.fa.omron.co.jp/data_pdf/cat/g9sp_f090-e1_12_9_csm2603.pdf
... is connected to two or more Timers, the input terminals of those Timers must be wired properly so that they will not be different in phase or the terminals will be short-circuited to one ano...
https://www.fa.omron.co.jp/data_pdf/cat/h3ds_ds_e_5_4_csm88.pdf
...n terminals 21 and 23. 4 H3FA Operation Timing Charts and External Connections Wire the inputs so that the time range selector (terminals 2 and 3), reset input (terminal 4), and start input ...
https://www.fa.omron.co.jp/data_pdf/cat/h3fa_ds_e_8_3_csm89.pdf
...rmed whichever terminal is connected. Terminals 7 and 10 are not connected internally, however, so do not use them for cross-over wiring. Internal circuit 5 6 Unused 4 0V 3 2 8 1 11 (+) Gate ...
https://www.fa.omron.co.jp/data_pdf/cat/h5cc_l220-e1_3_2_csm1124436.pdf
...sier to understand, and the present value display can be switched between red, green and orange so that output status can be seen from a distance. *1. New Models (H5CX-@-N) with 100 to 240-VA...
https://www.fa.omron.co.jp/data_pdf/cat/h5cx-_-n_l111-e1_5_7_csm2122.pdf
...ing Environment !CAUTION Do not touch any of the terminals while power is being supplied. Doing so may result in electric shock. Be sure to mount the terminal cover after wiring. Do not use t...
https://www.fa.omron.co.jp/data_pdf/cat/h5f_ds_e_3_5_csm101.pdf
...ways maintain the load current within specifications. 20.Use a switch, relay, or other contacts so that the rated power supply voltage will be reached within 0.1 s. If the power supply voltag...
https://www.fa.omron.co.jp/data_pdf/cat/h5s_ds_e_9_4_csm103.pdf
...on for Use in Environments Subject to Water or Oil The panel surface has a protective structure so that the internal circuits will not be adversely affected if drops of water penetrate the ga...
https://www.fa.omron.co.jp/data_pdf/cat/h7bx_ds_e_5_2_csm1338.pdf
...or H7EC-NFV-@. If the counting speed setting is changed, the present value will not be held and so press the Reset Key on the front panel. The Reset Key is not operable while the key-protect ...
https://www.fa.omron.co.jp/data_pdf/cat/h7e_-n_ds_e_9_6_csm119.pdf
...low (according to DIN 43700). The mounting panel thickness must be 1 to 5 mm. Mount the Counter so that the ambient temperature will not exceed 55°C. 78 min. 68+0.7 0 68+0.7 0 13.7 78 min. 75...
https://www.fa.omron.co.jp/data_pdf/cat/h8bm-r_ds_e_5_6_csm749.pdf
...64 bit) CPU Intel® Xeon® Processor E3-1515M v5 (2.8 GHz/3.7 GHz, 4 cores/8 threads) Main memory SO-DIMM 32 GB max. (ECC supported), DDR4 SDRAM Storage RAID0/1 configuration using Intel® RST (...
https://www.fa.omron.co.jp/data_pdf/cat/industrial_pc_platform_ny_series_p133-e1-01.pdf