IAグローバル検索 |
...lectors Appearance Number of notches Reset method Key release position Model Rectangular (A165K-J) 2 notches Manual A165K-J2ML A165K-J2MR A165K-J2M Automatic A165K-J2AL 3 notches Manual A165K...
...and Socket. Not all combinations are possible. Ask your OMRON representative for details. M16[]-J (Rectangular) Models Solder Terminal Models Appearance Degree of protection IP40 IP66 oil-res...
...em Specification Model number CJ1W-TC00[] CJ1W-TC10[] Temperature sensor Thermocouple: R, S, K, J, T, L, B Platinum resistance thermometer: Pt100, JPt100 Number of loops 4 loops or 2 loops wi...
https://www.ia.omron.com/products/family/1438/specification.html
... and scaling can be set individually for each of 2 inputs, which are each selectable from B, E, J, K, L, N, R, S, T, U, WRe5-26, PL II, and mV. Scaling Data to be stored in the allocated word...
https://www.ia.omron.com/products/family/1644/specification.html
...lowed frequency of Z-pulses is 1 kHz Filter Selection Timing requirement (μs) A B C D E F G H I J 10 kHz <3 >50 >100 >23 >10 >100 >50 >100 >23 >10 50 kHz <3 >10 >20 >4.5 >10 >20 >10 >20 >4.5 ...
https://www.ia.omron.com/products/family/1649/specification.html
... Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE[][] Universal-input (th...
https://www.ia.omron.com/products/family/166/specification.html
...2CH 1CH Resolution: 1/6000 CP1W-MAD11 Temperature Sensor Unit 2CH -- Sensor type: Thermocouple (J or K) CP1W-TS001 4CH -- Sensor type: Thermocouple (J or K) CP1W-TS002 2CH -- Sensor ...
...2CH 1CH Resolution: 1/6000 CP1W-MAD11 Temperature Sensor Unit 2CH -- Sensor type: Thermocouple (J or K) CP1W-TS001 4CH -- Sensor type: Thermocouple (J or K) CP1W-TS002 2CH -- Sensor ...
...prox. 630 g SCCR (UL508) * 9 kA --- * Obtained through coordination with a 30 A (Class CC/Class J) fuse. Refer to Catalog for details. last update: November 6, 2023...
https://www.ia.omron.com/products/family/1924/specification.html
...0 Hz)/ 100 to 125 VDC No-voltage input 0.05 s to 300 h Eight multi-modes: A, B, B2, C, D, E, G, J H3CR-A 24 to 48 VAC (50/60 Hz)/ 12 to 48 VDC 100 to 240 VAC (50/60 Hz)/ 100 to 125 VDC Voltag...
... Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay J: One-shot A: ON-delay (power supply start) B: Flicker OFF start (power supply start) B2: Flic...
https://www.ia.omron.com/products/family/193/specification.html
...nput type Platinum resistance thermometer: Pt100 (JIS, IEC), Pt1000, or JPt100 Thermocouple: K, J, T, L, R, S, or B Current: 4 to 20 mA, or 0 to 20 mA Voltage: 1 to 5 V, 0 to 5 V, or 0 to 10 ...
https://www.ia.omron.com/products/family/1988/specification.html
...C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval (Signal or Power) G: Signal ON/OFF-delay J: One-shot (Signal or Power) A: ON-delay B2: Flicker ON start E: Interval J: One-shot...
https://www.ia.omron.com/products/family/201/specification.html
... Either use the CT Cable specified by OMRON or use 1.25-B3A crimp terminals and AWG22 wire from J.S.T. Mfg. Co., Ltd. last update: October 1, 2015...
https://www.ia.omron.com/products/family/2646/specification.html
... Either use the CT Cable specified by OMRON or use 1.25-B3A crimp terminals and AWG22 wire from J.S.T. Mfg. Co., Ltd. last update: October 1, 2015...
https://www.ia.omron.com/products/family/2714/specification.html
...A (24 VAC) Approx. 2.5 W (24 VDC) Sensor input Models with thermocouple inputs Thermocouple: K, J, T, R, or S (JIS C 1602-1995, IEC60584-1) Models with platinum resistance thermometer inputs ...
https://www.ia.omron.com/products/family/3024/specification.html
...d 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3101/specification.html
...d 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3102/specification.html
...ce thermometer if condensation is likely to result. Sheathed Thermocouples Element type K (CA), J(IC) Class JIS class 2 (0.75) Thermal contact Non-grounded type Sheath material CA: ASTM316L I...
https://www.ia.omron.com/products/family/3150/specification.html
...50°C to 250°C SUS304 E52-P6FY Low-cost thermocouple E52-CA[]ASY E52-IC[]ASY 0°C to 400°C K (CA) J (IC) Non- grounded type 2 (0.75) E52-CA1DY E52-IC1DY Grounded type E52-CA6F-N E52-CA6F-N-25 E...