IAグローバル検索 |
...In: 2 / Analog Out: 2 Tool Conn. Digital In: 3 / Digital Out: 3 I/O Power Supply Control Box 24 V 2.0 A Tool 24 V 1.5 A Ingress Protection IP54 for Robot Arm, AC control Box, Robot S...
https://www.ia.omron.com/products/family/3911/specification.html
... Field (red), and long-range Torch lighting (white) Imager Field of View Angles 34.6° H x 26.3° V nominal Environmental Operating Temperature -32° F to 104° F / 0°C to 40°C Storage Temperatur...
https://www.ia.omron.com/products/family/3913/specification.html
...ni- cations cable Communi- cations functions Units per CPU Unit No. of unit numbers allocated 5 V sys- tem 24 V sys- tem CJ1 CPU Bus Unit EtherNet/IP Unit Shielded twisted- pair (STP...
...1, 2024 Product Line-up Model Mono- chrome/ Color Reso- lution Frame Rate Effective Pixels (H x V) Sensor Size Cell Size (μm) Sensor Lens Mount General Specifi- cations STC-STS502CXP122 * Col...
...1, 2024 Product Line-up Model Mono- chrome/ Color Reso- lution Frame Rate Effective Pixels (H x V) Sensor Size Cell Size (μm) Sensor General Specifi- cations STC-BBS43U3V-VF096 Monochrome 0.4...
...ategory AC-15 DC-13 Rated operating current (Ie) 0.75 A 0.55 A Rated operating voltage (Ue) 240 V 125 V UL/CSA (UL508, CSA C22.2 No.14), CCC (GB/T 14048.5) 300 mA at 24 VDC (Inductiv...
https://www.ia.omron.com/products/family/396/specification.html
... power supply voltage: 30 VDC max. Load current: 100 mA max. (Residual voltage: NPN output: 1.2 V max., PNP output: 2.0 V max.) Open controller output (NPN/PNP selectable) Light-ON/D...
https://www.ia.omron.com/products/family/412/specification.html
...10 mA min. DC SSR output (E3JM-[][]S4 (T)(-[]) model): 48 VDC, 100 mA max. (residual voltage: 2 V max.) Light-ON/Dark-ON selectable Life expectancy (relay output) Mechanical 50,000,000 times ...
https://www.ia.omron.com/products/family/421/specification.html
...cator input Open collector with relay or transistor input Indicator ON: Input voltage of 0 to 2 V Indicator OFF: Open (with leakage current of 0.1 mA max.) Protection circuits Reverse-connect...
https://www.ia.omron.com/products/family/424/specification.html
...pecifications Dimensions Catalog last update: December 13, 2012 Ratings Power supply voltage 18 V (use two 9-V dry-cell batteries) Input configuration Operates when the output transi...
https://www.ia.omron.com/products/family/432/specification.html
... current: 50 mA max. OFF current: 0.5 mA max. 50 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency * 2...
https://www.ia.omron.com/products/family/437/specification.html
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *2 ...
https://www.ia.omron.com/products/family/438/specification.html
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *3 ...
https://www.ia.omron.com/products/family/440/specification.html
...urrent: 100 mA max. OFF current: 0.5 mA max. 100 mA load current with a residual voltage of 0.8 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *2 ...
https://www.ia.omron.com/products/family/441/specification.html
... voltage: 12 to 24 VDC, Load current: 100 mA max., OFF current: 0.5 mA max. Residual voltage: 1 V max (at a 100-mA load current) Response time 1 ms max. for both detection and reset Ambient i...
https://www.ia.omron.com/products/family/442/specification.html
... current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *3 ...
https://www.ia.omron.com/products/family/443/specification.html
...urrent: 100 mA max. OFF current: 0.5 mA max. 100 mA load current with a residual voltage of 0.8 V max. 40 mA load current with a residual voltage of 0.4 V max. Response frequency *2 ...
https://www.ia.omron.com/products/family/444/specification.html
...tput 100 mA max. at 12 VDC (30 VDC max.) 200 mA max. at 24 VDC (30 VDC max.) Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) 2 V max. (Load current: 200 mA, Cable...
https://www.ia.omron.com/products/family/454/specification.html
...ntrol output Load current NPN open-collector output, 100 mA max. (at 30 VDC) Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Operation...
https://www.ia.omron.com/products/family/457/specification.html
...urrent E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA Residual voltage E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on Data S...
https://www.ia.omron.com/products/family/471/specification.html