...C 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each in X, Y, and Z directions for 2 h Shock resistance Destruction: 500 m/s 2 3 times each in ...
...ject Ferrous metal (Sensitivity lowers with non-ferrous metals.) Standard sensing object Iron 5 x 5 x 1 mm Response frequency 1 kHz (Average value) Power supply voltage 5 to 24 VDC r...
...em list >E2K-L13MC1 2M Liquid Level Sensor English 日本語 Print Page Image Sensing head size 24 mm x 43 mm x 20 mm Type Square type, Capacitive type, Unshielded Power source DC Three...
...em list >E2K-L26MC1 2M Liquid Level Sensor English 日本語 Print Page Image Sensing head size 33 mm x 34 mm x 20 mm Type Square type, Capacitive type, Unshielded Power source DC Three...
... >E2S-W22 5M Super-compact Proximity Sensor English 日本語 Print Page Image Sensing head size 8 mm x 7.4 mm x 20 mm Type Square type, Unshielded Power source DC 2-wire models Sensing...
...tem list >GLS-1L Magnetic Proximity Sensor English 日本語 Print Page Image Sensing head size 50 mm x 14 mm x 14 mm Type Square type, Magnetic type Sensing distance 15 mm Item list of...
...nsing distance Sensing object Ferrous metal, Non-ferrous metal Standard sensing object Iron 200 x 200 x 1 mm Response time 100 ms max. Power supply voltage 10 to 30 VDC ripple (p-p) ...
...ct Ferrous metal (Sensitivity lowers with non-ferrous metals.) Standard sensing object Iron 100 x 100 x 1 mm Response time 15 ms max. Power supply voltage 12 to 24 VDC ripple (p-p) 1...
...ct Ferrous metal (Sensitivity lowers with non-ferrous metals.) Standard sensing object Iron 100 x 100 x 1 mm Response time 15 ms max. Power supply voltage 12 to 24 VDC ripple (p-p) 1...
...ct Ferrous metal (Sensitivity lowers with non-ferrous metals.) Standard sensing object Iron 100 x 100 x 1 mm Response time 25 ms max. Power supply voltage 100 to 220 VAC Operating vo...
...ct Ferrous metal (Sensitivity lowers with non-ferrous metals.) Standard sensing object Iron 100 x 100 x 1 mm Response time 25 ms max. Power supply voltage 100 to 220 VAC Operating vo...
...pe Sensing distance Slot width: 3.6 mm Operation mode Dark-ON Standard sensing object Opaque, 1 x 0.5 mm min. Differential distance elements 0.05 mm max. Light source (Peak wavelength) GaAs...
...pe Sensing distance Slot width: 3.6 mm Operation mode Dark-ON Standard sensing object Opaque, 1 x 0.5 mm min. Differential distance elements 0.05 mm max. Light source (Peak wavelength) GaAs...
...type Sensing distance Slot width: 5 mm Operation mode Dark-ON Standard sensing object Opaque, 2 x 0.8 mm min. Differential distance elements 0.05 mm max. Light source (Peak wavelength) GaAs...
...pe Sensing distance Slot width: 3.6 mm Operation mode Dark-ON Standard sensing object Opaque, 1 x 0.5 mm min. Differential distance elements 0.05 mm max. Light source (Peak wavelength) GaAs...
...e Sensing distance Slot width: 3.6 mm Operation mode Light-ON Standard sensing object Opaque, 1 x 0.5 mm min. Differential distance elements 0.05 mm max. Light source (Peak wavelength) GaAs...
...e Sensing distance Slot width: 3.6 mm Operation mode Light-ON Standard sensing object Opaque, 1 x 0.5 mm min. Differential distance elements 0.05 mm max. Light source (Peak wavelength) GaAs...
...ype Sensing distance Slot width: 5 mm Operation mode Light-ON Standard sensing object Opaque, 2 x 0.8 mm min. Differential distance elements 0.05 mm max. Light source (Peak wavelength) GaAs...
... of different polarity) Vibration resistance Malfunction: 10 to 55 Hz, 20 m/s 2 for 2 h each in X, Y, and Z directions Shock resistance Malfunction: 150 m/s 2 , in each 6 directions 3 times A...
... of different polarity) Vibration resistance Malfunction: 10 to 55 Hz, 20 m/s 2 for 2 h each in X, Y, and Z directions Shock resistance Malfunction: 150 m/s 2 , in each 6 directions 3 times A...