| IAグローバル検索 |
...re No corrosive gas Vibration resistance (destruction) 10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions 8 min each, 10 times Shock resistance (destruction) 150 m/s 2 3 times each in ...
https://www.ia.omron.com/products/family/3070/specification.html
...uble amplitude and 57 to 150 Hz variable vibration at 9.8 m/s 2 acceleration, with 10 sweeps in X, Y, and Z directions for 8 minutes each Shock resistance 147 m/s 2 in X, Y, and Z di...
https://www.ia.omron.com/products/family/3086/specification.html
...uble amplitude and 57 to 150 Hz variable vibration at 9.8 m/s 2 acceleration, with 10 sweeps in X, Y, and Z directions for 8 minutes each Shock resistance 147 m/s 2 in X, Y, and Z di...
https://www.ia.omron.com/products/family/3087/specification.html
...minute Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions Shock resistance (destruction) 500 m/s 2 3 times each in X, Y, ...
https://www.ia.omron.com/products/family/3104/specification.html
...minute Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions Shock resistance (destruction) 500 m/s 2 3 times each in X, Y, ...
https://www.ia.omron.com/products/family/3107/specification.html
...case Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance Destruction: 500 m/s 2 3 times each in X, Y and...
https://www.ia.omron.com/products/family/3130/specification.html
...re No corrosive gas Vibration resistance (destruction) 10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions 8 min each, 10 times Shock resistance (destruction) 150 m/s 2 3 times each in ...
https://www.ia.omron.com/products/family/3131/specification.html
...case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s 2 10 times each in X, Y, ...
https://www.ia.omron.com/products/family/3144/specification.html
...d storage atmosphere No corrosive gases Vibration resistance * Acceleration of 49 m/s 2 max. in X, Y, and Z directions Impact resistance Acceleration of 98 m/s 2 max. 3 times each in ...
https://www.ia.omron.com/products/family/3145/specification.html
...re No corrosive gas Vibration resistance (destruction) 10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions 8 min each, 10 times Shock resistance (destruction) 150 m/s 2 3 times each in ...
https://www.ia.omron.com/products/family/3149/specification.html
...C) Lead wire Fully glass-wool-covered compensating cable and external dimensions of approx. 5.1 x 3.0 4/0.65 0°C to 180°C Note: The sleeve resists temperatures ranging between 0°C and 100°C. ...
https://www.ia.omron.com/products/family/3151/specification.html
...ge 0°C to permissible temperature limit Lead wire Vinyl-covered with external dimensions of 2.4 x 4.1 7/0.3 -20°C to 70°C Permissible Temperature in Dry Air D Element wire K (CA) ASTM316L 3.2...
https://www.ia.omron.com/products/family/3152/specification.html
...ight: 80,000lx or less Vibration resistance 10 to 150 Hz, half amplitude 0.35 mm, 3 directions (X/Y/Z), 8 minutes each 10 times Degree of protection IP54 (IEC60529) Weight Main unit only Appr...
https://www.ia.omron.com/products/family/3173/specification.html
...ht: 100,000 lx or less Vibration resistance 10 to 150 Hz, half amplitude 0.35 mm, 3 directions (X/Y/Z), 8 minutes each 10 times Degree of protection IP65 (IEC60529) Weight Main unit only Appr...
https://www.ia.omron.com/products/family/3174/specification.html
...in digital 8-segment red LED, 6 digits Sub-digital 8-segment green LEDs, 6 digits LCD 16 digits x 2 rows, Color of characters: green, Resolution per character: 5 x 8 pixel matrix Set...
https://www.ia.omron.com/products/family/3175/specification.html
...on) 10 to 60 Hz with a 0.7-mm double amplitude, 50 m/s 2 at 60 to 150 Hz, for 1.5 hours each in X, Y, and Z directions Shock resistance (destruction) 150 m/s 2 for 3 times each in X,...
https://www.ia.omron.com/products/family/3177/specification.html
... humidity: 0% to 95%) Vibration resistance 10 to 55 Hz, 0.375 mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s 2 , 3 times each in ±X, ±Y, and ±Z dir...
https://www.ia.omron.com/products/family/3178/specification.html
...Vibration resistance Destruction 10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions Malfunction 10 to 55 Hz with a 1.5 mm double amplitude for 2 hours each ...
https://www.ia.omron.com/products/family/3179/specification.html
... lowest point) Vibration resistance (destruction) 100 m/s 2 (20 to 2,000 Hz) 20 minutes each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s 2 3 times each in X, Y...
https://www.ia.omron.com/products/family/3180/specification.html
...case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s 2 10 times each in X, Y, ...
https://www.ia.omron.com/products/family/3181/specification.html