IAグローバル検索 |
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1 Use a switch for micro load...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1 Use a switch for micro load...
...lay which turns the laser power ON/OFF based on the signal from the interlock connector. Model: G7SA-2A2B DC24 Mounting screw hole 100mm Locating hole 100mm Mounting screw hole 300 Exhaust Sp...
https://www.omron-ap.com.ph/data_pdf/mnu/mx-z2000h-v1_-z2050h-v1_-z2055h-v1_inst-5636570-7c.pdf
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power *1. If the External Device Mon...
https://www.omron-ap.com.ph/data_pdf/mnu/os32c_inst-99863-0020l.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor : Load or PLC (for monitoring) KM3 KM4 :Solid state contactor (G3J)...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor : Load or PLC (for monitoring) KM3 KM4 :Solid state contactor (G3J)...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
...cuit to 24V if the switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...onnect to 24V if a switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...(connect to 0 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 1.0 m...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 3 mA)...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1. Use a switch for small ...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1. Use a switch for small loa...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1. Use a switch for small ...
https://www.omron-ap.com.ph/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power *1. If the External Device Mon...
https://www.omron-ap.com.ph/data_pdf/mnu/z296-e1-15_os32c.pdf
...e to 0 V if this switch is not required.) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...
https://www.omron-ap.com.ph/data_pdf/mnu/z380-e1-04_f3sg-4ra____-25-01ts.pdf
...l Earth Beam state Unblocked Blocked OSSD KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: Motor *1. Connect the line to 24 V via a test switch (N.O. contact) if External Test i...
https://www.omron-ap.com.ph/data_pdf/mnu/z391-e1-03_f3sg-4ar____-25-02ts.pdf
...uting] : Disable S1: Lockout reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor *1. Reverse the polarity of the power supply when using in...
https://www.omron-ap.com.ph/data_pdf/mnu/z405-e1-07_f3sg-sr_pg.pdf
...the laser power ON/OFF based on the 15 Safety relay signal from the interlock connector. Model: G7SA-2A2B DC24 *1 Do not use the USB interface for anything other than specified. Fiber Laser M...
https://www.omron-ap.com.ph/data_pdf/mnu/z415-e1-08_mx-z2000h-v1.pdf
...11 VDC min. OFF voltage 5 VDC max. OFF current Input current (DST1-MRD08SL-1) Applicable relays G7SA-2A2B, EN50205 Class A 1 mA max. Failure rate P level * (Reference value) 5 VDC, 1 mA 6 mA ...
https://www.omron-ap.com/data_pdf/cat/dst1_series_ds_e_7_4_csm1275.pdf