Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 981 - 10001419
PDF[5132821-8D] F3SG-4RA□□□□-25-01TSシリーズ セーフティライトカーテン...

...onnect to 0V if a switch is not required) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/f3sg-4ra____-25-01tsseries(quickinstallationmanual)_inst-5132821-8d.pdf

PDF[9309529-9E] F3SG-4RA□□□□-25-02TS セーフティライトカーテン クイッ...

...M1 KM2 +24 VDC Power Supply KM2 0 VDC KM1 KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor KM2 M *1. Connect the line to 24 V via a test switch (N.O. contact) if E...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/f3sg-4ra____-25-02ts(quickinstallationmanual)_inst-9309529-9e.pdf

PDF[Z380-E1-04] F3SG-4RA[][][][]-25-01TS Safety Light...

...e to 0 V if this switch is not required.) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z380-e1-04_f3sg-4ra____-25-01ts.pdf

PDF[Z391-E1-03] F3SG-4RA[][][][]-25-02TS Series Safet...

...l Earth Beam state Unblocked Blocked OSSD KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: Motor *1. Connect the line to 24 V via a test switch (N.O. contact) if External Test i...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z391-e1-03_f3sg-4ar____-25-02ts.pdf

PDF「制御盤革新」 を製品力へ: アルバックが起こす制御盤革新。 面積30%削減で

...H3RN-B セーフティ共用ソケット共用ソケットスリムI/Oリレーリレーソケット (MY/H3Y(N)-B用) (G2R-S/H3RN-B/K7L-B用) G2RV-SR (G7SA用) PYF-PU(-L) P2RF-PU P7SA-PU スリムI/Oリレー G3RV-SR ヒ...

https://www.fa.omron.co.jp/member/solution/panel/samc-012a-1.pdf

PDF制御盤BASIC Electrical Control Safety

...ッチング・パワーサプライ S8VK-S ソリッドステート・タイマ H3DT 監視リレー K8DT セーフティリレーソケット (G7SA用) P7SA-PU 共用ソケット (MY/H3Y(N)-B用) PYF-PU(-L) 押ボタンスイッチプッシ...

https://www.fa.omron.co.jp/member/solution/panel/samc-013a-web1.pdf

PDFMulti-vendor Network Multi-vendor Network DeviceNe...

...类型源流输出(PNP对应) 额定输出电流每点输出最大0.7A ON剩余电压最大1.2 V 漏电流最大0.1 mA 适用继电器G7SA-2A2B、EN50205 Class A P级失效率* (参考值)DC5V,1 mA 额定负载(电阻)AC240V时2A、DC30...

https://www.fa.omron.com.cn/data_pdf/closed/cat/csm_drt2_devicenet_ca_c_20_14_discon.pdf

PDFMulti-vendor Network

... 0.7 A max./output ON residual voltage 1.2 V max. Leakage current 0.1 mA max. Applicable relays G7SA-2A2B, EN50205 Class A Failure rate P level * (Reference value) 5 VDC, 1 mA Rated load (res...

https://www.fa.omron.com.cn/data_pdf/closed/cat/drt2_devicenet_q102-e1_20_37_csm2147.pdf

PDF长距离检测型安全光幕F3SL 266 ᅝܼ Ӵᛳ఼ F3SJ F3SL

...,进行F3SL的配线。 M:三相电机等设备驱动部 S1:互锁复位用启动开关(NC接点) MPCE1、MPCE2:带强制导向机构的安全继电器(推荐:G7SA)及接触器注1.作为进行设备最终控制的继电器MPCE1和MPCE2,请使用...

https://www.fa.omron.com.cn/data_pdf/closed/cat/f3sl_ds_c_1_1.pdf

PDFCSM_F3SL_DS_E_3_1 1 Safety Light Curtain for Long ...

...er has been turned OFF. Note: 1. Please use a relay with a forcibly guided contact (such as the G7SA) for MPCE1 and MPCE2, which are relays that perform ultimate control of the machine. 2. If...

https://www.fa.omron.com.cn/data_pdf/closed/cat/f3sl_ds_csm1259.pdf

PDF全面革新控制柜的提案 赋予控制柜全新的价值

...新产品 机械自动化控制器 NX系列 NX1P 新产品开关电源 S8VK-S(高容量型) *照片为240W 新产品 安全继电器插座 (G7SA用) P7SA-PU 新产品 按钮开关 Push-in Plus 端子台系列 A22N-P/A30N-P/M22N-P 新产品 I/...

https://www.fa.omron.com.cn/data_pdf/closed/cat/innovation_in_control_panel_building_samc-cn5-010_1_6_discon.pdf

PDF追求控制柜省工时的新标准 继电器、插座Push-In Plus端子台系列

...G2RV-SR/G3RV-SR(纤薄型I/O继电器) 赋予控制柜全新的价值 G6D-F4PU/G3DZ-F4PU(终端继电器) G70V(I/O继电器终端) P7SA-PU(安全继电器G7SA用插座) •用Push-In Plus端子台简单地配线 •支持上下任意安...

https://www.fa.omron.com.cn/data_pdf/closed/cat/pyf-pu_p2rf-pu_g2rv-sr_g3rv-sr_g70v_p7sa-pu_sgfr-cn5-219_1_10_discon.pdf

PDFA New Standard for Reducing Work in

.../O Relays) G6D-F4PU/G3DZ-F4PU (Terminal Relays) G70V (I/O Relay Terminals) P7SA-PU (Sockets for G7SA Relays with Forcibly Guided Contacts) •Sockets with Push-In Plus technology for easy wirin...

https://www.fa.omron.com.cn/data_pdf/closed/cat/pyf-pu_p2rf-pu_g2rv-st_g3rv-st_g70v_p7sa-pu_j213-e1_2_1_csm1050148.pdf

PDF降低环境负荷 实现可持续的控制柜制造 Value Design for Panel

...提供 32 Push-In Plus端子台继电器插座 PYF-□□-PU/PTF-□□-PU/ P2RF-□□-PU/P7SA-PU •MY继电器、LY继电器、G2R-S继电器以及安全继电器 G7SA的继电器用插座中新增节省工时的Push-In Plus 端子台型产品。 适用...

https://www.fa.omron.com.cn/data_pdf/closed/cat/value_design_for_panel_samc-cn5-030_1_1_discon.pdf

PDFSustainable control panel enable

...Sockets with Push-In Plus technology to Save Work Added to Series for MY, LY , G2R-S Relays and G7SA Relays with Forcibly Guided Contacts Applicable model (typical example) No. of poles Model...

https://www.fa.omron.com.cn/data_pdf/closed/cat/value_design_for_panel_y235-e1_6_4_csm1101680.pdf

PDFSensors Switches Safety Components Relays Control ...

...e Switching Gears •Sockets For Relays (MY, LY, G2R-S) For Relays with Forcibly Guided Contacts (G7SA) For Timers (H3Y-…-B and H3YN-B) For Liquid Leakage Sensor Amplifiers (K7L-……B) •Slim I/O ...

https://www.ia.omron.com/data_pdf/guide/46/connector_tg_e_3_1_push-in_plus_terminal_tg_e_2_2.pdf

PDFReliability Data for Safety of Machinery Safety Co...

...- - 9.0E+5 This product conforms to IEC 61810-3 Forcibly Guided Contact Structure. Safety Relay G7SA AC-1 AC250V 6A, DC-1 DC30V 6A - - - - - - 4.0E+5 This product conforms to IEC 61810-3 Forc...

https://www.ia.omron.com/support/sistemalibrary/data/omron_safety_components_en_20241001.pdf

PDF制御機器の機械安全信頼性データセーフティコンポ オムロン株式会社2024/10/1データは予告なく変...

...す。 セーフティリレーG7S-□-E AC-15 240V 0.75A - - - - - - 9.0E+5 IEC 61810-3 (強制ガイド接点構造)に適合しています。 セーフティリレーG7SA AC-1 AC250V 6A, DC-1 DC30V 6A - - - - - - 4.0E+5 IEC ...

https://www.ia.omron.com/support/sistemalibrary/data/omron_safety_components_jp_20241001.pdf

F3SJ-A0245N14 セーフティライトカーテン | オムロン制御機器

... 省スペース取付金具: F39-LJ8 形F3W-C置換え用取付金具: F39-LJ9 上下取付金具C: F39-LJ11 その他アクセサリ セーフティリレー: G7SA-2A2B、G7SA-3A1B、G7S-4A2B-E、G7S-3A3B-E コネクタ中継ボッ...

https://www.fa.omron.co.jp/product/item/F3SJ-A0245N14/

F3SJ-A0245N20 セーフティライトカーテン | オムロン制御機器

... 省スペース取付金具: F39-LJ8 形F3W-C置換え用取付金具: F39-LJ9 上下取付金具C: F39-LJ11 その他アクセサリ セーフティリレー: G7SA-2A2B、G7SA-3A1B、G7S-4A2B-E、G7S-3A3B-E コネクタ中継ボッ...

https://www.fa.omron.co.jp/product/item/F3SJ-A0245N20/

結果 981 - 10001419

国/地域選択

Related Contents