| IAグローバル検索 |
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power *1. If the External Device Mon...
https://www.omron.com.vn/data_pdf/mnu/os32c_inst-99863-0020n.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor : Load or PLC (for monitoring) KM3 KM4 :Solid state contactor (G3J)...
https://www.omron.com.vn/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor : Load or PLC (for monitoring) KM3 KM4 :Solid state contactor (G3J)...
https://www.omron.com.vn/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.omron.com.vn/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
...cuit to 24V if the switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron.com.vn/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...onnect to 24V if a switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron.com.vn/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...(connect to 0 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 1.0 m...
https://www.omron.com.vn/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 3 mA)...
https://www.omron.com.vn/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1. Use a switch for small ...
https://www.omron.com.vn/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1. Use a switch for small loa...
https://www.omron.com.vn/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
...connect to 24 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1. Use a switch for small ...
https://www.omron.com.vn/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power *1. If the External Device Mon...
...uting] : Disable S1: Lockout reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor *1. Reverse the polarity of the power supply when using in...
https://www.omron.com.vn/data_pdf/mnu/z405-e1-08_f3sg-sr_pg.pdf
...the laser power ON/OFF based on the 15 Safety relay signal from the interlock connector. Model: G7SA-2A2B DC24 *1 Do not use the USB interface for anything other than specified. Fiber Laser M...
https://www.omron.com.vn/data_pdf/mnu/z415-e1-10_mx-z2000h-v1.pdf
...ンから後ろを切って表示しています。 ※ カタログ情報の確認は、上部メニューの「商品情報」からご確認ください。 G7S G7SA P7SA 関連情報...
https://www.fa.omron.co.jp/product/rohs/safety-components/s_relay/
...s 3PST-NO, 3PST-NC 2D / 3D G7S-4A2B-E Basic Model , 10A Type , 6 Poles 4PST-NO, DPST-NC 2D / 3D G7SA-2A2B Basic Model , 4 poles (DPST-NO, DPST-NC) 2D / 3D G7SA-3A1B Basic Model , 4 p...
https://www.omron.com.tw/products/family/1581/download/cad.html
...ing connector system F3W-MA0100P F3W-MA0300P Smart Muting Actuator Note: See p.147 for details. G7SA/G7S-E Relays with Forcibly Guided Contacts * The recommended safety controller is required...
https://www.fa.omron.co.jp/data_pdf/closed/cat/f3sg-r_f094-e1_12_7_csm1040037.pdf
...r LY Relays) G70V (I/O Relay Terminals) P2RF-PU (Sockets for G2R-S Relays) P7SA-PU (Sockets for G7SA Relays with Forcibly Guided Contacts) G2RV-ST/G3RV-ST (Slim I/O Relays) A New Standard for...
...レー) PTF-PU(LYリレー用ソケット) G70V(I/Oリレーターミナル) P2RF-PU(G2R-Sリレー用ソケット) P7SA-PU(セーフティリレーG7SA用ソケット) G2RV-ST/G3RV-ST (スリムI/Oリレー) 制御盤の省工数を...
...Sockets with Push-In Plus technology to Save Work Added to Series for MY, LY , G2R-S Relays and G7SA Relays with Forcibly Guided Contacts Applicable model (typical example) Size W×H×D (mm) 2 ...
https://www.fa.omron.co.jp/data_pdf/closed/cat/value_design_for_panel_y235-e1_6_4_csm1101680.pdf