IAグローバル検索 |
...switch S2: Lockout/interlock reset switch KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor M: Motor *1. Reverse the polarity of the power supply when using in...
https://www.omron-ap.com/data_pdf/cat/f3sg-sr_pg_f117-e1_1_8_csm1120108.pdf
...utput F3SJ-E Accessories (Sold separately) Relays with Forcibly Guided Contacts Type Appearance G7SA Relays with Forcibly Guided Contacts G7S-@-E Relays with Forcibly Guided Contacts Specific...
https://www.omron-ap.com/data_pdf/cat/f3sj_f074-e1_27_11_csm1816.pdf
... of enclosed construction. Therefore, do not wash the G7S with water or detergent. Mounting The G7SA can be installed in any direction. 5 Terms and Conditions Agreement Read and understand th...
https://www.omron-ap.com/data_pdf/cat/g7s-_-e_ds_e_7_3_csm1272.pdf
...Relays with Forcibly Guided Contacts G7SA Compact, Slim Relays Conforming to EN Standards • Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditiona...
https://www.omron-ap.com/data_pdf/cat/g7sa_j120-e1_12_11_csm1269.pdf
.../3 equivalent Model Stop category Reset 0 Manual Safety Laser Scanner OS32C Forced Guided Relay G7SA Note: The above PL is only the evaluation result of the example. The PL must be evaluated ...
https://www.omron-ap.com/data_pdf/cat/os32c_z298-e1_14_6_csm2602.pdf
...注意ください。 項目出力タイプ定格出力電流 ON残電圧 ● 安全出力部仕様 (リレー出力) 項目仕様使用リレー G7SA-2A2B,IEC61810-3 Class A 故障率 P水準(参考値 * ) DC5V 1mA 定格負荷(抵抗負荷) AC24...
https://www.omron-ap.com/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf
...onnect to 0V if a switch is not required) KM1, KM2: Safety relay with forcibly guided contacts (G7SA) or magnetic contactor E1: 24VDC power supply (S8VS) PLC: Programmable controller (Used fo...
...M1 KM2 +24 VDC Power Supply KM2 0 VDC KM1 KM1, KM2: Safety relay with forcibly guided contacts (G7SA) M: 3-phase motor KM2 M *1. Connect the line to 24 V via a test switch (N.O. contact) if E...
...equired) S2 : Interlock/lockout reset switch KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor K1 : Load or PLC, etc. (for monitoring) *1 Use a switch for micro l...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1 Use a switch for micro load...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1 Use a switch for micro load...
... switch (connect to 24 V if a switch is not required) : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) *1 Use a switch for micro load...
...lay which turns the laser power ON/OFF based on the signal from the interlock connector. Model: G7SA-2A2B DC24 Mounting screw hole 100mm Locating hole 100mm Mounting screw hole 300 Exhaust Sp...
https://www.omron-ap.com/data_pdf/mnu/mx-z2000h-v1_-z2050h-v1_-z2055h-v1_inst-5636570-7c.pdf
...r releasing lockout) S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor M1 : 3-Phase Motor E1 : 24 VDC Power *1. If the External Device Mon...
https://www.omron-ap.com/data_pdf/mnu/os32c_inst-99863-0020l.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor : Load or PLC (for monitoring) KM3 KM4 :Solid state contactor (G3J)...
https://www.omron-ap.com/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor : Load or PLC (for monitoring) KM3 KM4 :Solid state contactor (G3J)...
https://www.omron-ap.com/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
...quired) S2 :Interlock/lockout reset switch KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J)...
https://www.omron-ap.com/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
...cuit to 24V if the switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron-ap.com/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...onnect to 24V if a switch is not required) KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S...
https://www.omron-ap.com/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...(connect to 0 V if a switch is not required) KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor *1. Use a switch for small loads (input specifications: 24 V, 1.0 m...
https://www.omron-ap.com/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf